The influence of water/air cooling on collateral tissue damage using a diode laser with an innovative pulse design (micropulsed mode)—an in vitro study

被引:0
作者
F. Beer
W. Körpert
A. G. Buchmair
H. Passow
A. Meinl
P. Heimel
A. Moritz
机构
[1] Medical University Vienna,Department of Conservative Dentistry, Dental School
[2] Danube University Krems,Department of Environmental and Medical Sciences, Centre for Interdisciplinary Dentistry
[3] Ludwig Boltzmann Institute for Experimental and Clinical Traumatology,Austrian Cluster for Tissue Regeneration, Histology
[4] Medical University of Vienna,Karl Donath Laboratory for Hard Tissue and Biomaterial Research, Department of Oral Surgery
来源
Lasers in Medical Science | 2013年 / 28卷
关键词
Diode laser; Thermal damage; Micropulsed; Soft tissue; Surgery;
D O I
暂无
中图分类号
学科分类号
摘要
Since the diode laser is a good compromise for the daily use in dental offices, finding usage in numerous dental indications (e.g., surgery, periodontics, and endodontics), the minimization of the collateral damage in laser surgery is important to improve the therapeutical outcome. The aim of this study was to investigate the effect of water/air cooling on the collateral thermal soft tissue damage of 980-nm diode laser incisions. A total of 36 mechanically executed laser cuts in pork liver were made with a 980-nm diode laser in micropulsed mode with three different settings of water/air cooling and examined by histological assessment to determine the area and size of carbonization, necrosis, and reversible tissue damage as well as incision depth and width. In our study, clearly the incision depth increased significantly under water/air cooling (270.9 versus 502.3 μm—test group 3) without significant changes of incision width. In test group 2, the total area of damage was significantly smaller than in the control group (in this group, the incision depth increases by 65 %). In test group 3, the total area of damage was significantly higher (incision depth increased by 85 %), but the bigger part of it represented a reversible tissue alteration leaving the amount of irreversible damage almost the same as in the control group. This first pilot study clearly shows that water/air cooling in vitro has an effect on collateral tissue damage. Further studies will have to verify, if the reduced collateral damage we have proved in this study can lead to accelerated wound healing. Reduction of collateral thermal damage after diode laser incisions is clinically relevant for promoted wound healing.
引用
收藏
页码:965 / 971
页数:6
相关论文
共 44 条
[1]  
Parker S(2007)Lasers and soft tissue: ‘loose’ soft tissue surgery Br Dent J 202 185-191
[2]  
Sulieman M(2005)An overview of the use of lasers in general dental practice: 1. Laser physics and tissue interactions Dent Update 32 228-230
[3]  
Scherer H(1994)Current status of laser surgery in the area of the soft palate and adjoining regions Laryngorhinootologie 73 14-20
[4]  
Luciano AA(1992)A comparative analysis of adhesion reduction, tissue effects, and incising characteristics of electrosurgery, CO J Laparoendosc Surg 2 287-292
[5]  
Frishman GN(2010) laser, and Nd:YAG laser at operative laparoscopy: an animal study Acta Odontol Scand 68 232-238
[6]  
Maier DB(1975)A comparative study of wound healing following incision with a scalpel, diode laser or Er, Cr:YSGG laser in guinea pig oral mucosa: a histological and immunohistochemical analysis J Bone Joint Surg Am 57 377-379
[7]  
Jin J-Y(2007)Healing of electrosurgical and scalpel wounds in rabbits Oral Surg Oral Med Oral Pathol Oral Radiol Endod 103 764-773
[8]  
Lee S-H(2007)A preliminary study of healing of diode laser versus scalpel incisions in rat oral tissue: a comparison of clinical, histological, and immunohistochemical results Ann Otol Rhinol Laryngol 116 853-857
[9]  
Yoon H-J(1996)Thermal damage during thulium laser dissection of laryngeal soft tissue is reduced with air cooling: ex vivo calf model study J Clin Laser Med Surg 14 381-384
[10]  
Tipton WW(2010)The effects of cooling systems on CO Med Oral Patol Oral Cir Bucal 15 e912-e918