The feasibility of the 1-h high-sensitivity cardiac troponin T algorithm to rule-in and rule-out acute myocardial infarction in Thai emergency patients: An observational study

被引:4
作者
Ruangsomboon O. [1 ]
Mekavuthikul P. [1 ]
Chakorn T. [1 ]
Monsomboon A. [1 ]
Prapruetkit N. [1 ]
Surabenjawong U. [1 ]
Limsuwat C. [1 ]
Riyapan S. [1 ]
Chaisirin W. [1 ]
机构
[1] Department of Emergency Medicine, Siriraj Hospital, Mahidol University, 2 Wangland Rd., Bangkoknoi Bangkok
关键词
1-h hs-cTnT algorithm; Acute myocardial infarction; Chest pain; Emergency department; High-sensitivity cardiac troponin T;
D O I
10.1186/s12245-018-0204-9
中图分类号
学科分类号
摘要
Background: The 3-h high-sensitivity cardiac troponin T (hs-cTnT) algorithm is the most commonly used scheme to diagnose acute myocardial infarction. The 1-h hs-cTnT algorithm has recently been approved by the European Society of Cardiology as an alternative algorithm for earlier diagnosis. If the hs-cTnT test cannot discriminate the diagnosis of the patient at 1 h, the patient is defined as observational group. Their test must be repeated at 3 h. A high prevalence of this group may indicate a low clinical utility of the 1-h hs-cTnT algorithm. This study was aimed to estimate the proportion of the observational group in Thai emergency department (ED) patients and also the time to rule-in/out between both the algorithms. Methods: A historical control study was conducted in patients with chest pain for 1-12 h at the ED of Siriraj Hospital, Bangkok, Thailand. The study compared two groups: one prospective group of all patients evaluated with the 1-h hs-cTnT algorithm between June and September 2017 and one historical control group evaluated with the 3-h hs-cTnT algorithm between January and March 2017. Results: A total of 130 patients were included (3-h hs-cTnT algorithm group n = 65 and 1-h hs-cTnT algorithm group n = 65). Twelve patients [18.5% (95% CI 10.0-30.1)] were categorized as observational group in the 1-h hs-cTnT algorithm group. The mean rule-in/out times in the 3-h hs-cTnT algorithm and 1-h hs-cTnT algorithm groups were 238 min (SD 63.3) and 134 min (SD 68.5), respectively (both p < 0.001). The time to disposition was also shortened in the 1-h hs-cTnT algorithm group (p < 0.001). Multivariable regression analysis performed to identify and adjust for confounders among patient characteristics revealed no significant confounders. Conclusions: The use of the 1-h hs-cTnT algorithm in the ED resulted in an acceptable proportion in the observational group and a decreased time to rule-in/out compared with the 3-h hs-cTnT algorithm. © 2018 The Author(s).
引用
收藏
相关论文
共 50 条
  • [21] Diagnostic performance of cardiac Troponin I for early rule-in and rule-out of acute myocardial infarction: Results of a prospective multicenter trial
    Storrow, Alan B.
    Christenson, Robert H.
    Nowak, Richard M.
    Diercks, Deborah B.
    Singer, Adam J.
    Wu, Alan H. B.
    Kulstad, Erik
    LoVecchio, Frank
    Fromm, Christian
    Headden, Gary
    Potis, Tracie
    Hogan, Christopher J.
    Schrock, Jon W.
    Zelinski, Daniel P.
    Greenberg, Marna R.
    Ritchie, James C.
    Chamberlin, Janna S.
    Bray, Kurtis R.
    Rhodes, Daniel W.
    Trainor, Deirdre
    Holmes, Dawn
    Southwick, Paula C.
    CLINICAL BIOCHEMISTRY, 2015, 48 (4-5) : 254 - 259
  • [22] Use of historical high-sensitivity cardiac troponin T levels to rule out myocardial infarction
    Roos, Andreas
    Holzmann, Martin J.
    OPEN HEART, 2021, 8 (01):
  • [23] Combining presentation high-sensitivity cardiac troponin I and glucose measurements to rule-out an acute myocardial infarction in patients presenting to emergency department with chest pain
    Greenslade, J. H.
    Kavsak, P.
    Parsonage, W.
    Shortt, C.
    Than, M.
    Pickering, J. W.
    Aldous, S.
    Cullen, L.
    CLINICAL BIOCHEMISTRY, 2015, 48 (4-5) : 288 - 291
  • [24] Comparison of a single high-sensitivity cardiac troponin T measurement with the HEART score for rapid rule-out of acute myocardial infarction in a primary care emergency setting: a cohort study
    Johannessen, Tonje R.
    Atar, Dan
    Vallersnes, Odd Martin
    Larstorp, Anne Cecilie K.
    Mdala, Ibrahimu
    Halvorsen, Sigrun
    BMJ OPEN, 2021, 11 (02):
  • [25] Combined testing of copeptin and high-sensitivity cardiac troponin T at presentation in comparison to other algorithms for rapid rule-out of acute myocardial infarction
    Mueller-Hennessen, Matthias
    Lindahl, Bertil
    Giannitsis, Evangelos
    Vafaie, Mehrshad
    Biener, Moritz
    Haushofer, Alexander C.
    Seier, Josef
    Christ, Michael
    Alquezar-Arbe, Aitor
    DeFilippi, Christopher R.
    McCord, James
    Body, Richard
    Panteghini, Mauro
    Jernberg, Tomas
    Plebani, Mario
    Verschuren, Franck
    French, John K.
    Christenson, Robert H.
    Dinkel, Carina
    Katus, Hugo A.
    Mueller, Christian
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2019, 276 : 261 - 267
  • [26] Adding historical high-sensitivity troponin T results to rule out acute myocardial infarction
    Roos, Andreas
    Mohammad, Moman A.
    Ekelund, Ulf
    Mokhtari, Arash
    Holzmann, Martin J.
    EUROPEAN HEART JOURNAL-ACUTE CARDIOVASCULAR CARE, 2022, 11 (03) : 215 - 223
  • [27] Clinical derivation and data simulated validation of rule-out and rule-in algorithms for the Siemens Atellica IM high-sensitivity cardiac troponin I assay
    Restan, Ingar Ziad
    Steiro, Ole-Thomas
    Pickering, John W.
    Tjora, Hilde L.
    Langorgen, Jorund
    Omland, Torbjorn
    Collinson, Paul
    Bjorneklett, Rune
    Vikenes, Kjell
    Steinsvik, Trude
    Skadberg, Oyvind
    Mjelva, oistein R.
    Larsen, Alf Inge
    Bonarjee, Vernon V. S.
    Aakre, Kristin M.
    EUROPEAN HEART JOURNAL-ACUTE CARDIOVASCULAR CARE, 2025, : 155 - 168
  • [28] Rapid rule-out of suspected acute coronary syndrome in the Emergency Department by high-sensitivity cardiac troponin T levels at presentation
    Andrea Fabbri
    Cristina Bachetti
    Filippo Ottani
    Alice Morelli
    Barbara Benazzi
    Sergio Spiezia
    Marco Cortigiani
    Romolo Dorizzi
    Allan S. Jaffe
    Marcello Galvani
    Internal and Emergency Medicine, 2019, 14 : 403 - 410
  • [29] Early Rule-Out Strategies in the Emergency Department Utilizing High-Sensitivity Cardiac Troponin Assays
    Lopez-Ayala, Pedro
    Boeddinghaus, Jasper
    Koechlin, Luca
    Nestelberger, Thomas
    Mueller, Christian
    CLINICAL CHEMISTRY, 2021, 67 (01) : 114 - 123
  • [30] Rapid Rule-Out of Acute Myocardial Injury Using a Single High-Sensitivity Cardiac Troponin I Measurement
    Sandoval, Yader
    Smith, Stephen W.
    Shah, Anoop. S. V.
    Anand, Atul
    Chapman, Andrew R.
    Love, Sara A.
    Schulz, Karen
    Cao, Jing
    Mills, Nicholas L.
    Apple, Fred S.
    CLINICAL CHEMISTRY, 2017, 63 (01) : 369 - 376