Multi-electrode array technologies for neuroscience and cardiology

被引:0
作者
Spira M.E. [1 ]
Hai A. [1 ]
机构
[1] Alexander Silberman Life Sciences Institute, Harvey M. Kruger Family Center for Nanoscience, Hebrew University of Jerusalem
关键词
D O I
10.1038/nnano.2012.265
中图分类号
学科分类号
摘要
At present, the prime methodology for studying neuronal circuit-connectivity, physiology and pathology under in vitro or in vivo conditions is by using substrate-integrated microelectrode arrays. Although this methodology permits simultaneous, cell-non-invasive, long-term recordings of extracellular field potentials generated by action potentials, it is 'blind' to subthreshold synaptic potentials generated by single cells. On the other hand, intracellular recordings of the full electrophysiological repertoire (subthreshold synaptic potentials, membrane oscillations and action potentials) are, at present, obtained only by sharp or patch microelectrodes. These, however, are limited to single cells at a time and for short durations. Recently a number of laboratories began to merge the advantages of extracellular microelectrode arrays and intracellular microelectrodes. This Review describes the novel approaches, identifying their strengths and limitations from the point of view of the end users-with the intention to help steer the bioengineering efforts towards the needs of brain-circuit research. © 2013 Macmillan Publishers Limited. All rights reserved.
引用
收藏
页码:83 / 94
页数:11
相关论文
共 89 条
[1]  
Hodgkin A.L., Huxley A.F., Action potentials recorded from inside a nerve fibre, Nature, 144, pp. 710-711, (1939)
[2]  
Grundfest H., The mechanisms of discharge of the electric organs in relation to general and comparative electrophysiology, Prog. Biophys. Biophys. Chem, 7, pp. 1-85, (1957)
[3]  
Sakmann B., Neher E., Patch clamp techniques for studying ionic channels in excitable membranes, Annu. Rev. Physiol, 46, pp. 455-472, (1984)
[4]  
Verkhratsky A., Krishtal O.A., Petersen O.H., From Galvani to patch clamp: The development of electrophysiology, Pflugers Arch, 453, pp. 233-247, (2006)
[5]  
Hutzler M., Et al., High-resolution multitransistor array recording of electrical field potentials in cultured brain slices, J. Neurophysiol, 96, pp. 1638-1645, (2006)
[6]  
Eytan D., Marom S., Dynamics and effective topology underlying synchronization in networks of cortical neurons, J. Neurosci, 26, pp. 8465-8476, (2006)
[7]  
Berdondini L., Et al., Active pixel sensor array for high spatio-temporal resolution electrophysiological recordings from single cell to large scale neuronal networks, Lab Chip, 9, pp. 2644-2651, (2009)
[8]  
Frey U., Egert U., Heer F., Hafizovic S., Hierlemann A., Microelectronic system for high-resolution mapping of extracellular electric fields applied to brain slices, Biosens. Bioelectron, 24, pp. 2191-2198, (2009)
[9]  
Hochberg L.R., Et al., Neuronal ensemble control of prosthetic devices by a human with tetraplegia, Nature, 442, pp. 164-171, (2006)
[10]  
Blanche T.J., Spacek M.A., Hetke J.F., Swindale N.V., Polytrodes: High-density silicon electrode arrays for large-scale multiunit recording, J. Neurophysiol, 93, pp. 2987-3000, (2005)