Computed Tomography of the SpineSystematic Review on Acquisition and Reconstruction Techniques to Reduce Radiation Dose

被引:0
作者
Michael Dieckmeyer
Nico Sollmann
Karina Kupfer
Maximilian T. Löffler
Karolin J. Paprottka
Jan S. Kirschke
Thomas Baum
机构
[1] Technical University of Munich,Department of Diagnostic and Interventional Neuroradiology, School of Medicine, Klinikum rechts der Isar
[2] Technical University of Munich,TUM
[3] University Hospital Ulm,Neuroimaging Center, Klinikum rechts der Isar
[4] University Medical Center Freiburg,Department of Diagnostic and Interventional Radiology
来源
Clinical Neuroradiology | 2023年 / 33卷
关键词
Multi-detector computed tomography; Dose reduction; Low dose; Image reconstruction; Image acquisition;
D O I
暂无
中图分类号
学科分类号
摘要
The introduction of the first whole-body CT scanner in 1974 marked the beginning of cross-sectional spine imaging. In the last decades, the technological advancement, increasing availability and clinical success of CT led to a rapidly growing number of CT examinations, also of the spine. After initially being primarily used for trauma evaluation, new indications continued to emerge, such as assessment of vertebral fractures or degenerative spine disease, preoperative and postoperative evaluation, or CT-guided interventions at the spine; however, improvements in patient management and clinical outcomes come along with higher radiation exposure, which increases the risk for secondary malignancies. Therefore, technical developments in CT acquisition and reconstruction must always include efforts to reduce the radiation dose. But how exactly can the dose be reduced? What amount of dose reduction can be achieved without compromising the clinical value of spinal CT examinations and what can be expected from the rising stars in CT technology: artificial intelligence and photon counting CT? In this article, we try to answer these questions by systematically reviewing dose reduction techniques with respect to the major clinical indications of spinal CT. Furthermore, we take a concise look on the dose reduction potential of future developments in CT hardware and software.
引用
收藏
页码:271 / 291
页数:20
相关论文
共 533 条
[1]  
Smith-Bindman R(2019)Trends in Use of Medical Imaging in US Health Care Systems and in Ontario, Canada, 2000–2016 JAMA 322 843-856
[2]  
Kwan ML(2012)Use of diagnostic imaging studies and associated radiation exposure for patients enrolled in large integrated health care systems, 1996–2010 JAMA 307 2400-2409
[3]  
Marlow EC(2007)Computed tomography—an increasing source of radiation exposure N Engl J Med 357 2277-2284
[4]  
Smith-Bindman R(2009)Radiation dose associated with common computed tomography examinations and the associated lifetime attributable risk of cancer Arch Intern Med 169 2078-2086
[5]  
Miglioretti DL(2010)Diagnostic CT radiation and cancer induction Skelet Radiol 39 421-424
[6]  
Johnson E(2009)Projected cancer risks from computed tomographic scans performed in the United States in 2007 Arch Intern Med 2009 2071-2077
[7]  
Lee C(2010)Practical and effective ALARA Health Phys 98 S39-S47
[8]  
Feigelson HS(2004)Radiation protection in humans: extending the concept of as low as reasonably achievable (ALARA) from dose to biological damage Br J Radiol 77 97-99
[9]  
Flynn M(2017)Optimizing Radiation Doses for Computed Tomography Across Institutions: Dose Auditing and Best Practices JAMA Intern Med 177 810-817
[10]  
Greenlee RT(2015)Radiation Doses in Consecutive CT Examinations from Five University of California Medical Centers Radiology 277 134-141