Digital tomosynthesis in cone-beam geometry for industrial applications: Feasibility and preliminary study

被引:0
作者
Min Kook Cho
Hanbean Youn
Sun Young Jang
Suk Lee
Myung-Chul Han
Ho Kyung Kim
机构
[1] Pusan National University,School of Mechanical Engineering
[2] Pusan National University,Center for Advanced Medical Engineering Research
来源
International Journal of Precision Engineering and Manufacturing | 2012年 / 13卷
关键词
Computed tomography; Filtered backprojection; Image reconstruction; Limited angle tomography; Nondestructive evaluation; Tomosynthesis;
D O I
暂无
中图分类号
学科分类号
摘要
We introduce a cone-beam computed tomography with insufficient projections obtained from a limited-angle scan, the socalled digital tomosynthesis, and demonstrate its feasibility for the industrial applications by implementing to the reconstruction of internal slice images of a multilayer printed circuit board. The image reconstruction algorithm is based on the filtered-backprojection approach for the cone-beam geometry with isocentric linear motion in the scanning trajectory of the X-ray source and imaging detector pair. Although the slice image reconstructed at the plane of interest was affected by the structures outside, we could reconstruct the plane of interest with the total scan angle less than 20 degrees and 11 projections. The digital tomosynthesis is expected to be practical for industrial tomography restricted to the limited-angle scan.
引用
收藏
页码:1533 / 1538
页数:5
相关论文
共 120 条
  • [1] Kalender W. A.(2006)X-ray Computed Tomography Phys. Med. Biol. 51 R29-R43
  • [2] Pan X.(2008)Anniversary Paper: Development of X-ray Computed Tomography: The Role of Medical Physics and AAPM from the 1970s to Present Med. Phys. 35 3728-3739
  • [3] Siewerdsen J.(2008)Computed Tomography Systems in Medicine: Past, Present and Future J. KSPE 25 35-42
  • [4] La Riviere P. J.(2009)Performance Characterization of Microtomography with Complementary Metal-oxidesemiconductor Detectors for Computer-aided Defect Inspection J. Appl. Phys. 105 134-150
  • [5] Kalender W. A.(1987)Three-dimensional X-ray Microtomography Science 237 1439-1444
  • [6] Yin Z.(2000)Computed Tomography with Image Intensifier: Potential Use for Nondestructive Testing and Imaging of Small Objects NDT&E Int. 33 523-530
  • [7] Kim H. K.(2008)On the Development of Digital Radiography Detectors: A Review Int. J. Precis. Eng. Manuf. 9 86-100
  • [8] Kim H. K.(2000)Cone-beam computed tomography with a flat-panel imager: Initial performance characterization Med. Phys. 27 1311-1323
  • [9] Yun S.(2005)Use of a flat-panel detector for microtomography: A feasibility study for small-animal imaging IEEE Trans. Nucl. Sci. 52 193-198
  • [10] Han J. C.(2010)Evaluation of sparse-view reconstruction from flat-panel-detector cone-beam CT Phys. Med. Biol. 55 6575-6599