A highly sensitive sensor of paracetamol based on zinc-layered hydroxide-L-phenylalanate-modified multiwalled carbon nanotube paste electrode

被引:0
作者
Mohamad Syahrizal Ahmad
Illyas Md Isa
Norhayati Hashim
Suyanta M. Si
Mohamad Idris Saidin
机构
[1] Sultan Idris Education University,Nanotechnology Research Centre, Faculty of Science and Mathematics
[2] Sultan Idris Education University,Department of Chemistry, Faculty of Science and Mathematics
[3] Yogyakarta State University,Department of Chemistry Education, Faculty of Mathematics and Natural Science
[4] MIMOS Bhd.,Advanced Analytical Services Laboratory
[5] Technology Park of Malaysia,undefined
来源
Journal of Solid State Electrochemistry | 2018年 / 22卷
关键词
Paracetamol; Multiwalled carbon nanotubes; Square wave voltammetry; Chronocoulometry; Zinc layered hydroxide-; -phenylalanate;
D O I
暂无
中图分类号
学科分类号
摘要
A new zinc-layered hydroxide-L-phenylalanate (ZLH-LP)-modified multiwalled carbon nanotube (MWCNT) was prepared as a new material of paste electrode for the detection of paracetamol (PCM) in 1.0 × 10−1 M phosphate buffer solution and at pH 7.5. The electrochemical characterization of the MWCNTs/ZLH-LP paste electrode was characterized by square wave voltammetry, electrochemical impedance spectroscopy, and cyclic voltammetry while the morphology properties of the MWCNTs, ZLH-LP, and MWCNTs/ZLH-LP were investigated using transmission electron microscopy and scanning electron microscopy. Under optimized conditions, the MWCNTs/ZLH-LP paste electrode demonstrated an excellent electrocatalytic activity towards oxidation of PCM in the linear responses’ ranges from 7.0 × 10−7 M to 1.0 × 10−4 M (correlation coefficient, 0.996) with the limit of detection obtained at 8.3 × 10−8 M. As a conclusion, the MWCNTs/ZLH-LP paste electrode revealed good repeatability, reproducibility, and stability, and was found to be applicable for use in pharmaceutical tablet samples.
引用
收藏
页码:2691 / 2701
页数:10
相关论文
共 198 条
  • [1] Bosch ME(2006)Determination of paracetamol: historical evolution J Pharm Biomed Anal 42 291-321
  • [2] Sanchez AJR(2006)Votammetric determination of paracetamol at C Electrochim Acta 51 3008-3012
  • [3] Rojas FS(2007) modified glassy carbon electrode Talanta 72 1818-1827
  • [4] Ojeda CB(2001)Amperometric determination of paracetomol by a surface modified cobalt hexacyanoferrate graphite wax composite electrode Crit Rev Toxicol 31 55-138
  • [5] Goyal RN(2008)Paracetamol (acetaminophen) induced toxicity: molecular and biochemical mechanisms, analogues and protective approaches Exp Toxicol Pathol 59 319-327
  • [6] Singh SP(2008)Acetaminophen-induced liver damage in mice: effects of some medicinal plants on the oxidative defense system J Med Toxicol 4 2-6
  • [7] Prabakar SJR(2013)Acetaminophen induced nephrotoxicity: pathophysiology, clinical manifestations, and management Clin Liver Dis 17 575-586
  • [8] Narayanan SS(2003)Drug induced acute liver failure J Pharm Biomed Anal 33 191-197
  • [9] Bessems JGM(2006)Flow injection spectrophotometric determination of paracetamol in tablets and oral solutions J Chromatogr B 839 95-101
  • [10] Vermeulen NPE(2002)Optimization of a capillary zone electrophoresis method by using a central composite factorial design for the determination of codeine and paracetamol in pharmaceuticals Pak J Sci Ind Res 45 7-9