Computerized anesthesia record keeping in thoracic surgery-Suitability of electronic anesthesia records in evaluating predictors for hypoxemia during one-lung ventilation

被引:4
作者
Sticher J. [1 ]
Junger A. [1 ]
Hartmann B. [1 ]
Benson M. [1 ]
Jost A. [1 ]
Golinski M. [1 ]
Scholz S. [1 ]
Hempelmann G. [1 ]
机构
[1] Department of Anaesthesiology, Intensive Care, and Pain Management, University Hospital Giessen
关键词
Computerized anesthesia record keeping; Hypoxemia; Multivariate analysis; One-lung ventilation; Risk factors; Thoracic surgery;
D O I
10.1023/A:1024294700397
中图分类号
学科分类号
摘要
Objective. The aim of this retrospective study was to assess the suitability of routine data gathered with a computerized anesthesia record keeping system in investigating predictors for intraoperative hypoxemia (SpO2 < 90%) during one-lung ventilation (OLV) in pulmonary surgery. Methods. Over a four-year period data of 705 patients undergoing thoracic surgery (pneumonectomy: 78; lobectomy: 292; minor pulmonary resections: 335) were recorded online using an automated anesthesia record-keeping system. Twenty-six patient-related, surgery-related and anesthesia-related variables were studied for a possible association with the occurrence of intraoperative hypoxemia during OLV. Data were analyzed using univariate and multivariate (logistic regression) analysis (p < 0.05). The model's discriminative power on hypoxemia was checked with a receiver operating characteristic (ROC) curve. Calibration was tested using the Hosmer-Lemeshow goodness-of-fit test. Results. An intraoperative incidence of hypoxemia during OLV was found in 67 patients (9.5%). Using logistic regression with a forward stepwise algorithm, body-mass-index (BMI, p = 0.018) and preoperative existing pneumonia (p = 0.043) could be detected as independent predictors having an influence on the incidence of hypoxemia during OLV. An acceptable goodness-of-fit could be observed using cross validation for the model (C = 8.21, p = 0.370, degrees of freedom, df 8; H = 3.21, p = 0.350, df 3), the discriminative power was poor with an area under the ROC curve of 0.58 [0.51-0.66]. Conclusions. In contrast to conventional performed retrospective studies, data were directly available for analyses without any manual intervention. Due to incomplete information and imprecise definitions of parameters, data of computerized anesthesia records collected in routine are helpful but not satisfactory in evaluating risk factors for hypoxemia during OLV.
引用
收藏
页码:335 / 343
页数:8
相关论文
共 50 条
  • [21] Jugular bulb venous oxygen saturation during one-lung ventilation under sevoflurane- or propofol-based anesthesia for lung surgery
    Iwata, Masato
    Inoue, Satoki
    Kawaguchi, Masahiko
    Takahama, Makoto
    Tojo, Takashi
    Taniguchi, Shigeki
    Furuya, Hitoshi
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2008, 22 (01) : 71 - 76
  • [22] A comparison of the effects of propofol-alfentanil versus isoflurane anesthesia on arterial oxygenation during one-lung ventilation
    Reid, CW
    Slinger, PD
    Lenis, S
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 1996, 10 (07) : 860 - 863
  • [23] Impact of Left Heart Bypass on Arterial Oxygenation During One-Lung Ventilation for Thoracic Aortic Surgery
    Suga, Kikuko
    Kobayashi, Yoshiro
    Ochiai, Ryoichi
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2017, 31 (04) : 1197 - 1202
  • [24] Effect of high-frequency jet ventilation on oxygenation during one-lung ventilation in patients undergoing thoracic aneurysm surgery
    Abe K.
    Oka J.
    Takahashi H.
    Funatsu T.
    Fukuda H.
    Miyamoto Y.
    Journal of Anesthesia, 2006, 20 (1) : 1 - 5
  • [25] Repeated intermittent hypoxic stimuli to operative lung reduce hypoxemia during subsequent one-lung ventilation for thoracoscopic surgery: A randomized controlled trial
    Yoon, Susie
    Kim, Bo Rim
    Min, Se-Hee
    Lee, Jaehun
    Bahk, Jae-Hyon
    Seo, Jeong-Hwa
    PLOS ONE, 2021, 16 (04):
  • [26] A systematic review of one-lung ventilation during thoracic surgery comparing the safety and efficacy of high and low tidal volumes
    Julian Camilleri-Brennan
    Nandesh Patel
    Sarah Mok
    David Ryan
    Blair Wilson
    Mikolaj Kotts
    Olivia Morton
    Mong Tung
    Peter Alston
    Journal of Cardiothoracic Surgery, 10 (Suppl 1)
  • [27] Comparison of the effects of isoflurane versus propofol-remifentanil anesthesia on oxygen delivery during thoracoscopic lung lobectomy with one-lung ventilation in dogs
    Park, Jiyoung
    Lee, Hae-Beom
    Jeong, Seong Mok
    JOURNAL OF VETERINARY SCIENCE, 2018, 19 (03) : 426 - 433
  • [28] Is small tidal volume with low positive end expiratory pressure during one-lung ventilation an effective ventilation method for endoscopic thoracic surgery?
    Yun, Du Gyun
    Han, Jong In
    Kim, Dong Yeon
    Kim, Jong Hak
    Kim, Youn Jin
    Chung, Rack Kyung
    KOREAN JOURNAL OF ANESTHESIOLOGY, 2014, 67 (05) : 329 - 333
  • [29] Predicting intraoperative hypoxemia in lung resection surgery: assessing the utility of oxygen reserve index measurements during one-lung ventilation before pleural opening
    Lee, Sang-Wook
    Kim, Ji-Yoon
    Choi, Dae-Kee
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2025, : 631 - 639
  • [30] Effect of desflurane-remifentanil vs. Propofol-remifentanil anesthesia on arterial oxygenation during one-lung ventilation for thoracoscopic surgery: a prospective randomized trial
    Cho, Youn Joung
    Kim, Tae Kyong
    Hong, Deok Man
    Seo, Jeong-Hwa
    Bahk, Jae-Hyon
    Jeon, Yunseok
    BMC ANESTHESIOLOGY, 2017, 17