Technological quality requirements for stereotactic radiotherapyExpert review group consensus from the DGMP Working Group for Physics and Technology in Stereotactic Radiotherapy

被引:0
作者
Daniela Schmitt
Oliver Blanck
Tobias Gauer
Michael K. Fix
Thomas B. Brunner
Jens Fleckenstein
Britta Loutfi-Krauss
Peter Manser
Rene Werner
Maria-Lisa Wilhelm
Wolfgang W. Baus
Christos Moustakis
机构
[1] Universitätsklinikum Heidelberg,Klinik für Radioonkologie und Strahlentherapie, National Center for Radiation Research in Oncology (NCRO), Heidelberger Institut für Radioonkologie (HIRO)
[2] Universitätsklinikum Schleswig-Holstein,Klinik für Strahlentherapie
[3] Universitätsklinikum Hamburg-Eppendorf,Klinik für Strahlentherapie und Radioonkologie
[4] Universität Bern,Abteilung für Medizinische Strahlenphysik und Universitätsklinik für Radio
[5] Universitätsklinikum Magdeburg,Onkologie, Inselspital—Universitätsspital Bern
[6] Universität Heidelberg,Universitätsklinik für Strahlentherapie
[7] Universitätsklinikum Frankfurt,Klinik für Strahlentherapie und Radioonkologie, Universitätsmedizin Mannheim
[8] Universitätsklinikum Hamburg-Eppendorf,Klinik für Strahlentherapie und Onkologie
[9] Universitätsmedizin Rostock,Institut für Computational Neuroscience
[10] Universitätsklinikum Köln,Klinik für Strahlentherapie
[11] Universitätsklinikum Münster,Klinik für Radioonkologie, CyberKnife
来源
Strahlentherapie und Onkologie | 2020年 / 196卷
关键词
Radiosurgery; Recommendations; Technique; SRS; FSRT; SBRT;
D O I
暂无
中图分类号
学科分类号
摘要
This review details and discusses the technological quality requirements to ensure the desired quality for stereotactic radiotherapy using photon external beam radiotherapy as defined by the DEGRO Working Group Radiosurgery and Stereotactic Radiotherapy and the DGMP Working Group for Physics and Technology in Stereotactic Radiotherapy. The covered aspects of this review are 1) imaging for target volume definition, 2) patient positioning and target volume localization, 3) motion management, 4) collimation of the irradiation and beam directions, 5) dose calculation, 6) treatment unit accuracy, and 7) dedicated quality assurance measures. For each part, an expert review for current state-of-the-art techniques and their particular technological quality requirement to reach the necessary accuracy for stereotactic radiotherapy divided into intracranial stereotactic radiosurgery in one single fraction (SRS), intracranial fractionated stereotactic radiotherapy (FSRT), and extracranial stereotactic body radiotherapy (SBRT) is presented. All recommendations and suggestions for all mentioned aspects of stereotactic radiotherapy are formulated and related uncertainties and potential sources of error discussed. Additionally, further research and development needs in terms of insufficient data and unsolved problems for stereotactic radiotherapy are identified, which will serve as a basis for the future assignments of the DGMP Working Group for Physics and Technology in Stereotactic Radiotherapy. The review was group peer-reviewed, and consensus was obtained through multiple working group meetings.
引用
收藏
页码:421 / 443
页数:22
相关论文
共 655 条
[1]  
Guckenberger M(2020)Definition and quality requirements for stereotactic radiotherapy—Consensus Statement from the DEGRO / DGMP Working Group Stereotactic Radiotherapy and Radiosurgery Strahlenther Onkol 37 4078-4101
[2]  
Baus WW(2010)Stereotactic body radiation therapy: the report of AAPM task group 101 Med Phys 14 1-160
[3]  
Blanck O(2014)ICRU report 91. Prescribing, recording, and reporting of stereotactic treatments with small photon beams J ICRU 121 187-192
[4]  
Benedict SH(2016)Consensus opinion on MRI simulation for external beam radiation treatment planning Radiother Oncol 44 e43-e76
[5]  
Yenice KM(2017)Use of image registration and fusion algorithms and techniques in radiotherapy: report of the AAPM radiation therapy committee task group no. 132 Med Phys 31 153-163
[6]  
Followill D(2012)Image similarity and tissue overlaps as surrogates for image registration accuracy: widely used but unreliable IEEE Trans Med Imaging 127 225-232
[7]  
Seuntjens J(2018)Influence of deformable image registration on 4D dose simulation for extracranial SBRT: a multi-registration framework study Radiother Oncol 190 521-532
[8]  
Lartigau EF(2014)Stereotactic radiosurgery for treatment of brain metastases. A report of the DEGRO Working Group on Stereotactic Radiotherapy Strahlenther Onkol 100 436-442
[9]  
Cora S(2018)Consensus contouring guidelines for postoperative completely resected cavity stereotactic radiosurgery for brain metastases Int J Radiat Oncol Biol Phys 93 126-132
[10]  
Paulson ES(2015)Interval from imaging to treatment delivery in the radiation surgery age: how long is too long? Int J Radiat Oncol Biol Phys 102 727-733