The effectiveness of phase change materials in relation to summer thermal comfort in air-conditioned office buildings

被引:0
|
作者
Vincenzo Costanzo
Gianpiero Evola
Luigi Marletta
Francesco Nocera
机构
[1] University of Reading,School of the Built Environment
[2] University of Catania,Department of Electric, Electronic and Computer Engineering
来源
Building Simulation | 2018年 / 11卷
关键词
organic PCMs; lightweight buildings; thermal comfort; energy savings; melting frequency;
D O I
暂无
中图分类号
学科分类号
摘要
The incorporation of Phase Change Materials (PCMs) into the opaque envelope of lightweight buildings is a good solution to compensate for the small thermal inertia, which usually entails pronounced overheating and high space cooling load in summer. However, the position and the thickness of the PCMs, as well as their thermal properties, must be attentively selected in order to ensure their effective operation. This paper shows a comprehensive investigation about the effectiveness of a commercial PCM, available in the form of mats, when installed within drywall partition systems in air-conditioned lightweight office buildings. The study is based on dynamic simulations carried out with EnergyPlus on a typical office building, with the aim to calculate the indoor operative temperature and the cooling load under thermostatic control. The performance for the base case (without PCM) is then compared with the case where PCM mats with various thickness and melting temperature are applied. The analysis is repeated in three different locations, ranging from Southern Europe (Rome, Italy), Continental Europe (Wien, Austria) and Northern Europe (London, UK). The results of the simulations highlight that in lightweight air-conditioned office buildings PCMs contribute to attenuate the inside surface temperature peak by around 0.5 °C, while also reducing the peak cooling load by 10% or even 15%, depending on the PCM thickness and on the outdoor climate. The conclusions may help designers to make the correct choices in terms of thickness of the PCMs, scheduled rate of nighttime ventilation and value of the peak melting temperature.
引用
收藏
页码:1145 / 1161
页数:16
相关论文
共 50 条
  • [21] Subjective Perception of Thermal Comfort Study in Air-Conditioned University Laboratories
    Hussin, M.
    Ismail, M. R.
    Ahmad, M. S.
    PSU-USM INTERNATIONAL CONFERENCE ON HUMANITIES AND SOCIAL SCIENCES, 2013, 91 : 192 - 200
  • [22] Appraisal of Thermal Comfort in Non-Air-conditioned and Air-conditioned Railway Pantry Car Kitchens
    Alam, Md. Sarfaraz
    Muthiah, Arunachalam
    Salve, Urmi Ravindra
    INTERNATIONAL JOURNAL OF INTEGRATED ENGINEERING, 2020, 12 (08): : 318 - 327
  • [23] The differences in thermal physiological parameters, thermal comfort, and thermal acceptability under the same thermal sensation in air-conditioned environments between winter and summer
    Liu, Weiwei
    Li, Shan
    Yang, Diyu
    Xu, Jun
    Sun, Liangliang
    Lin, Weibin
    ENERGY AND BUILDINGS, 2025, 333
  • [24] Transient analysis and improvement of indoor thermal comfort for an air-conditioned room with thermal insulations
    Prakash, D.
    AIN SHAMS ENGINEERING JOURNAL, 2015, 6 (03) : 947 - 956
  • [25] Thermal Comfort and its Relation to Ventilation Approaches in Non-Air-Conditioned Mosque Buildings
    Rasli, Nur Baitul Izati
    Ramli, Nor Azam
    Ismail, Mohd Rodzi
    Zainordin, Nazatul Syadia
    Shith, Syabiha
    Nazir, Amni Umirah Mohamad
    INTERNATIONAL JOURNAL OF INTEGRATED ENGINEERING, 2019, 11 (02): : 12 - 23
  • [26] Human Responses to the Thermal Comfort in Air-Conditioned Building: A Climate Chamber Study
    Ismail, Ahmad Rasdan
    Jusoh, Norfadzilah
    Zein, Raemy Md
    INTERNATIONAL JOURNAL OF INTEGRATED ENGINEERING, 2022, 14 (01): : 287 - 295
  • [27] Thermal and visual comfort of schoolchildren in air-conditioned classrooms in hot and humid climates
    Noda, Lumy
    Lima, Amanda V. P.
    Souza, Jullyanne F.
    Leder, Solange
    Quirino, Luana M.
    BUILDING AND ENVIRONMENT, 2020, 182
  • [28] Field study on thermal comfort in naturally ventilated and air-conditioned university classrooms
    Fabozzi, Michael
    Dama, Alessandro
    INDOOR AND BUILT ENVIRONMENT, 2020, 29 (06) : 851 - 859
  • [29] Transient thermal comfort during summer in air-conditioned indoor and naturally ventilated transitional spaces - A field study in Zhengzhou, China
    Li, Ruixin
    Liu, Jiahui
    Chen, Xin
    Zhang, Wenjian
    Lei, Tingshuo
    Chen, Jiacong
    Xia, Yuanli
    Bantserova, Olga L.
    ENERGY AND BUILDINGS, 2025, 328
  • [30] Experimental Analysis of Thermal Comfort in an Air Conditioned Open Space Office
    Wolf, Igor
    STROJARSTVO, 2010, 52 (06): : 651 - 663