Use of gas chromatography-ion trap tandem mass spectrometry for the detection and characterization of microorganisms in complex samples

被引:0
作者
Lennart Larsson
Anita Saraf
机构
[1] University of Lund,Department of Medical Microbiology
来源
Molecular Biotechnology | 1997年 / 7卷
关键词
GC-MS; GC-MS-MS; ion trap; endotoxin; peptidoglycan; ergosterol; diagnosis; detection;
D O I
暂无
中图分类号
学科分类号
摘要
Gas chromatography-mass spectrometry (GC-MS) can be applied to detect and characterize microorganisms in clinical and environmental samples, and microbial contaminants in biotechnological production cultures. With this approach, unique microbial monomeric compounds, known as chemical markers, are used as analytes. In the present article, two GC-MS-based techniques, viz. GC-ion trap tandem MS (GC-MS-MS) and conventional quadrupole GC-MS used in the selected ion monitoring mode, were compared regarding their ability to detect 3-hydroxy fatty acids, muramic acid, and ergosterol (markers for endotoxin, peptidoglycan, and fungal biomass, respectively) in complex matrices. When using GC-MS-MS, daughter ion spectra were obtained for all markers present in amounts close to the detection limit of the GC-MS. Ion-trap GC-MS-MS shows great promise as a chemical marker analysis technique for application in clinical diagnosis, occupational and public health care, and biotechnology.
引用
收藏
页码:279 / 287
页数:8
相关论文
共 128 条
[1]  
Alugupalli S.(1994)Systematic study of the 3-hydroxy fatty acid composition of mycobacteria J. Bacteriol. 176 2962-2969
[2]  
Portaels F.(1989)Chemical composition of a lipopolysaccharide from Arch. Microbiol. 153 72-78
[3]  
Larsson L.(1993)Sequential alkaline saponification/acid hydrolysis/esterification: a one-tube method with enhanced recovery of both cyclopropane and hydroxylated fatty acids J. Microbiol. Methods 18 21-32
[4]  
Sonesson A.(1992)Application of gas chromatography-mass spectrometry for rapid detection of Appl. Environ. Microbiol. 58 3538-3541
[5]  
Jantzen E.(1996) in drinking water J. Microbiol. Methods 27 229-232
[6]  
Bryn K.(1989)Rapid detection of Br. J. Ind. Med. 46 31-37
[7]  
Larsson L.(1991) in water by gas chromatography-mass spectrometry Int. Arch. Environ. Health 62 595-601
[8]  
Eng J.(1988)Environmental and health studies of farm workers in Swedish swine confinement buildings Am. Ind. Hyg. Assoc. J. 49 420-420
[9]  
Mayberry W. R.(1988)Relationship of airborne endotoxin and bacteria levels in pig farms with the lung function and respiratory symptoms of farmers J. Chromatogr. Biomed. Appl. 431 1-15
[10]  
Lane J. R.(1993)Airborne endotoxin associated with industrial-scale production of protein products in gramnegative bacteria J. Microbiol. Methods 17 91-102