Simultaneous analysis of buprenorphine, methadone, cocaine, opiates and nicotine metabolites in sweat by liquid chromatography tandem mass spectrometry

被引:0
作者
Marta Concheiro
Diaa M. Shakleya
Marilyn A. Huestis
机构
[1] Universidad de Santiago de Compostela,Servicio de Toxicología Forense, Dpto. Anatomía Patológica y Ciencias Forenses, Facultad de Medicina
[2] National Institutes of Health,Chemistry and Drug Metabolism, Intramural Research Program, National Institute on Drug Abuse
[3] National Institute on Drug Abuse,Chemistry and Drug Metabolism, Biomedical Research Center (BRC)
[4] NIH,undefined
来源
Analytical and Bioanalytical Chemistry | 2011年 / 400卷
关键词
Buprenorphine; Methadone; Cocaine; Cotinine; Sweat; Drug monitoring;
D O I
暂无
中图分类号
学科分类号
摘要
A liquid chromatography tandem mass spectrometry method for buprenorphine (BUP), norbuprenorphine (NBUP), methadone, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP), cocaine, benzoylecgonine, ecgonine methyl ester (EME), morphine, codeine, 6-acetylmorphine, heroin, 6-acetylcodeine, cotinine, and trans-3′-hydroxycotinine quantification in sweat was developed and comprehensively validated. Sweat patches were mixed with 6 mL acetate buffer at pH 4.5, and supernatant extracted with Strata-XC-cartridges. Reverse-phase separation was achieved with a gradient mobile phase of 0.1% formic acid and acetonitrile in 15 min. Quantification was achieved by multiple reaction monitoring of two transitions per compound. The assay was a linear 1–1,000 ng/patch, except EME 5–1,000 ng/patch. Intra-, inter-day and total imprecision were <10.1%CV, analytical recovery 87.2–107.7%, extraction efficiency 35.3–160.9%, and process efficiency 25.5–91.7%. Ion suppression was detected for EME (−63.3%) and EDDP (−60.4%), and enhancement for NBUP (42.6%). Deuterated internal standards compensated for these effects. No carryover was detected, and all analytes were stable for 24 h at 22 °C, 72 h at 4 °C, and after three freeze/thaw cycles. The method was applied to weekly sweat patches from an opioid-dependent BUP-maintained pregnant woman; 75.0% of sweat patches were positive for BUP, 93.8% for cocaine, 37.5% for opiates, 6.3% for methadone and all for tobacco biomarkers. This method permits a fast and simultaneous quantification of 14 drugs and metabolites in sweat patches, with good selectivity and sensitivity.
引用
收藏
页码:69 / 78
页数:9
相关论文
共 50 条
  • [31] Development and validation of a liquid chromatography mass spectrometry assay for the determination of opiates and cocaine in meconium
    Pichini, S
    Pacifici, R
    Pellegrini, M
    Marchei, E
    Pérez-Alarcón, E
    Puig, C
    Vall, O
    García-Algar, O
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 794 (02): : 281 - 292
  • [32] Simultaneous quantification of buprenorphine, norbuprenorphine, buprenorphine glucuronide, and norbuprenorphine glucuronide in human placenta by liquid chromatography mass spectrometry
    Concheiro-Guisan, Marta
    Shakleya, Diaa M.
    Huestis, Marilyn A.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 394 (02) : 513 - 522
  • [33] A high-throughput method based on microwave-assisted extraction and liquid chromatography-tandem mass spectrometry for simultaneous analysis of amphetamines, ketamine, opiates, and their metabolites in hair
    Chang, Yuan-Jhe
    Chao, Mu-Rong
    Chen, Su-Chin
    Chen, Chih-Hong
    Chang, Yan-Zin
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (9-10) : 2445 - 2455
  • [34] Simultaneous determination of opiates, methadone, amphetamines, cocaine, and metabolites in human placenta and umbilical cord by LC-MS/MS
    de Castro, Ana
    Diaz, Ariana
    Pineiro, Beatriz
    Lendoiro, Elena
    Cruz, Angelines
    Lopez-Rivadulla, Manuel
    Concheiro, Marta
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (12) : 4295 - 4305
  • [35] Online solid-phase extraction liquid chromatography-electrospray-tandem mass spectrometry analysis of buprenorphine and three metabolites in human urine
    Liu, An-Chan
    Lin, Tzuen-Yeuan
    Su, Lien-Wen
    Fuh, Ming-Ren
    TALANTA, 2008, 75 (01) : 198 - 204
  • [36] Chiral analysis of methadone and its major metabolites (EDDP and EMDP) by liquid chromatography-mass spectrometry
    Kelly, T
    Doble, P
    Dawson, M
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 814 (02): : 315 - 323
  • [37] Simultaneous Quantification of Diazepam, Flunitrazepam and Metabolites in Reinforced Clostridial Medium by Liquid Chromatography-Tandem Mass Spectrometry
    Martindale, Stephanie M.
    Powers, Robert H.
    Bell, Suzanne C.
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2015, 39 (01) : 29 - 34
  • [38] Simultaneous, quantitative determination of opiates, amphetamines, cocaine and benzoylecgonine in oral fluid by liquid chromatography quadrupole-time-of-flight mass spectrometry
    Mortier, KA
    Maudens, KE
    Lambert, WE
    Clauwaert, KM
    Van Bocxlaer, JF
    Deforce, DL
    Van Peteghem, CH
    De Leenheer, AP
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 779 (02): : 321 - 330
  • [39] Quantitative determination of buprenorphine, naloxone and their metabolites in rat plasma using hydrophilic interaction liquid chromatography coupled with tandem mass spectrometry
    Joshi, Anand
    Parris, Brian
    Liu, Yongzhen
    Heidbreder, Christian
    Gerk, Phillip M.
    Halquist, Matthew
    BIOMEDICAL CHROMATOGRAPHY, 2017, 31 (02)
  • [40] Quantification of cocaine and cocaine metabolites in dried blood spots from a controlled administration study using liquid chromatography-tandem mass spectrometry
    Ambach, Lars
    Menzies, Eleanor
    Parkin, Mark C.
    Kicman, Andrew
    Archer, John R. H.
    Wood, David M.
    Dargan, Paul I.
    Stove, Christophe
    DRUG TESTING AND ANALYSIS, 2019, 11 (05) : 709 - 720