Fixed-flexion radiography of the knee provides reproducible joint space width measurements in osteoarthritis

被引:0
作者
Manish Kothari
Ali Guermazi
Gabriele von Ingersleben
Yves Miaux
Martine Sieffert
Jon E. Block
Randall Stevens
Charles G. Peterfy
机构
[1] Synarc,Department of Scientific Client Services
[2] Inc.,Department of Reading Services
[3] Synarc,undefined
[4] Inc.,undefined
[5] Hoffmann-La Roche,undefined
来源
European Radiology | 2004年 / 14卷
关键词
Knee; Osteoarthritis; Radiography; Joint space width;
D O I
暂无
中图分类号
学科分类号
摘要
The validity of a non-fluoroscopic fixed-flexion radiographic acquisition and analysis protocol for measurement of joint space width (JSW) in knee osteoarthritis is determined. A cross-sectional study of 165 patients with documented knee osteoarthritis participating in a multicenter, prospective study of chondroprotective agents was performed. All patients had posteroanterior, weight-bearing, fixed-flexion radiography with 10° caudal beam angulation. A specially designed frame (SynaFlexer) was used to standardize the positioning. Minimum medial and lateral JSW were measured manually and twice by an automated analysis system to determine inter-technique and intra-reader concordance and reliability. A random subsample of 30 patients had repeat knee radiographs 2 weeks apart to estimate short-term reproducibility using automated analysis. Concordance between manual and automated medial JSW measurements was high (ICC=0.90); lateral compartment measurements showed somewhat less concordance (ICC=0.72). There was excellent concordance between repeated automated JSW measurements performed 6 months apart for the medial (ICC=0.94) and lateral (ICC=0.86) compartments. Short-term reproducibility for the subsample of 30 cases with repeat acquisitions demonstrated an average SD of 0.14 mm for medial JSW (CV=4.3%) and 0.23 mm for lateral JSW (CV=4.0%). Fixed-flexion radiography of the knee using a positioning device provides consistent, reliable and reproducible measurement of minimum JSW in knee osteoarthritis without the need for concurrent fluoroscopic guidance.
引用
收藏
页码:1568 / 1573
页数:5
相关论文
共 50 条
  • [1] Fixed-flexion radiography of the knee provides reproducible joint space width measurements in osteoarthritis
    Kothari, M
    Guermazi, A
    von Ingersleben, G
    Miaux, Y
    Sieffert, M
    Block, JE
    Stevens, R
    Peterfy, CG
    EUROPEAN RADIOLOGY, 2004, 14 (09) : 1568 - 1573
  • [2] Fixed-flexion knee radiography: the sensitivity to detect knee joint space narrowing in osteoarthritis
    Botha-Scheepers, S.
    Kloppenburg, M.
    Kroon, H. M.
    Le Graverand, M. -P. Hellio
    Breedveld, F. C.
    Ravaud, P.
    Dougados, M.
    OSTEOARTHRITIS AND CARTILAGE, 2007, 15 (03) : 350 - 353
  • [3] Optimization of the fixed-flexion knee radiograph
    Charles, H. C.
    Kraus, V. B.
    Ainslie, M.
    Le Graverand-Gastineau, M. -P. Hellio
    OSTEOARTHRITIS AND CARTILAGE, 2007, 15 (11) : 1221 - 1224
  • [4] Comparison of tibiofemoral joint space width measurements from standing CT and fixed flexion radiography
    Segal, Neil A.
    Frick, Eric
    Duryea, Jeffrey
    Nevitt, Michael C.
    Niu, Jingbo
    Torner, James C.
    Felson, David T.
    Anderson, Donald D.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2017, 35 (07) : 1388 - 1395
  • [5] Fixed-flexion knee radiography using a new positioning device produced highly repeatable measurements of joint space width: ELSA-Brasil Musculoskeletal Study (ELSA-Brasil MSK)
    Telles, Rosa Weiss
    Costa-Silva, Luciana
    Machado, Luciana A. C.
    Padilha dos Reis, Rodrigo Citton
    Barreto, Sandhi Maria
    REVISTA BRASILEIRA DE REUMATOLOGIA, 2017, 57 (02) : 154 - 161
  • [6] Reproducibility of joint space width and the intermargin distance measurements in patients with medial osteoarthritis of the knee in various degrees of flexion
    Takahashi, Toshiaki
    Yamanaka, Norio
    Ikeuchi, Masahiko
    Yamamoto, Haruyasu
    SKELETAL RADIOLOGY, 2009, 38 (01) : 37 - 42
  • [7] Reproducibility of joint space width and the intermargin distance measurements in patients with medial osteoarthritis of the knee in various degrees of flexion
    Toshiaki Takahashi
    Norio Yamanaka
    Masahiko Ikeuchi
    Haruyasu Yamamoto
    Skeletal Radiology, 2009, 38 : 37 - 42
  • [8] Fixed-flexion view X-ray of the knee superior in detection and follow-up of knee osteoarthritis
    Kan, Hiroyuki
    Arai, Yuji
    Kobayashi, Masashi
    Nakagawa, Shuji
    Inoue, Hiroaki
    Hino, Manabu
    Komaki, Shintaro
    Ikoma, Kazuya
    Ueshima, Keiichiro
    Fujiwara, Hiroyoshi
    Yokota, Isao
    Kubo, Toshikazu
    MEDICINE, 2017, 96 (49)
  • [9] Contribution of regional 3D meniscus and cartilage morphometry by MRI to joint space width in fixed flexion knee radiography-A between-knee comparison in subjects with unilateral joint space narrowing
    Bloecker, K.
    Wirth, W.
    Hunter, D. J.
    Duryea, J.
    Guermazi, A.
    Kwoh, C. K.
    Resch, H.
    Eckstein, F.
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (12) : E832 - E839
  • [10] Direct comparison of fixed flexion, radiography and MRI in knee osteoarthritis: responsiveness data from the Osteoarthritis Initiative
    Wirth, W.
    Duryea, J.
    Le Graverand, M. -P. Hellio
    John, M. R.
    Nevitt, M.
    Buck, R. J.
    Eckstein, F.
    OSTEOARTHRITIS AND CARTILAGE, 2013, 21 (01) : 117 - 125