The Australian radiation protection and nuclear safety agency megavoltage photon thermoluminescence dosimetry postal audit service 2007–2010

被引:0
作者
C. P. Oliver
D. J. Butler
D. V. Webb
机构
[1] Australian Radiation Protection and Nuclear Safety Agency (ARPANSA),
来源
Australasian Physical & Engineering Sciences in Medicine | 2012年 / 35卷
关键词
Audit; TLD; Quality assurance; Dosimetry;
D O I
暂无
中图分类号
学科分类号
摘要
The Australian radiation protection and nuclear safety agency (ARPANSA) has continuously provided a level 1 mailed thermoluminescence dosimetry audit service for megavoltage photons since 2007. The purpose of the audit is to provide an independent verification of the reference dose output of a radiotherapy linear accelerator in a clinical environment. Photon beam quality measurements can also be made as part of the audit in addition to the output measurements. The results of all audits performed between 2007 and 2010 are presented. The average of all reference beam output measurements calculated as a clinically stated dose divided by an ARPANSA measured dose is 0.9993. The results of all beam quality measurements calculated as a clinically stated quality divided by an ARPANSA measured quality is 1.0087. Since 2011 the provision of all auditing services has been transferred from the Ionizing Radiation Standards section to the Australian Clinical Dosimetry Service (ACDS) which is currently housed within ARPANSA.
引用
收藏
页码:105 / 108
页数:3
相关论文
共 11 条
[1]  
Huntley RB(1993)International atomic energy agency/World health organisation TLD radiotherapy dosimetry intercomparison Australas Phys Eng Sci Med 16 44-48
[2]  
Nette HP(2000)The 1998 Australian external beam radiotherapy survey and IAEA/WHO TLD postal dose quality audit Australas Phys Eng Sci Med 23 21-29
[3]  
Huntley R(2000)The IAEA/WHO TLD postal programme for radiotherapy hospitals Radiother Oncol 54 65-72
[4]  
Izewska J(2010)Monte Carlo simulation of correction factors for IAEA TLD holders Phys Med Biol 55 N161-N166
[5]  
Izewska J(2010)The 2009 survey of therapy equipment and dosimetry practices in Australian radiotherapy centres Australas Phys Eng Sci Med 33 285-297
[6]  
Andreo P(undefined)undefined undefined undefined undefined-undefined
[7]  
Hultqvist M(undefined)undefined undefined undefined undefined-undefined
[8]  
Fernandez-Varea JM(undefined)undefined undefined undefined undefined-undefined
[9]  
Izewska J(undefined)undefined undefined undefined undefined-undefined
[10]  
Brown RL(undefined)undefined undefined undefined undefined-undefined