Surface modification and machining of TiNi/TiNb-based alloys by electrical discharge machining

被引:2
作者
Shy-Feng Hsieh
Ming-Hong Lin
Sung-Long Chen
Shih-Fu Ou
Tyau-Song Huang
Xiao-Qian Zhou
机构
[1] National Kaohsiung University of Applied Sciences,Department of Mold and Die Engineering
[2] National Kaohsiung University of Applied Sciences,Department of Mechanical Engineering
来源
The International Journal of Advanced Manufacturing Technology | 2016年 / 86卷
关键词
Electrical discharge machining; Surface roughness; Titanium alloys;
D O I
暂无
中图分类号
学科分类号
摘要
Ti50Ni50 and Ti50Ni49.5Mo0.5 shape memory alloys and Ti30Nb1Fe1Hf alloy with a low elastic modulus were prepared for biomedical implant applications. Effects of the composition of the TiNi/TiNb-based alloys and electrical discharge machining (EDM) parameters on the properties of the materials were investigated. The addition of Mo to TiNi or of Nb to Ti clearly reduced the material removal rate (MRR), electrode wear rate, surface roughness, and recast layer thickness, which was attributed to the increased melting temperature and thermal conductivity of the materials. The surface roughness (Ra) of the electrical discharge machined (EDMed) alloys obeyed the empirical equation Ra = β(Ip × τp)α. A higher discharge current Ip combined with an appropriate pulse duration τp can achieve the highest MRR and lowest thickness of the recast layer. However, under low current and a small pulse duration, the recast layer has a surface roughness of 1 μm, which is favorable for oral implants. In addition, the EDMed surface contains Ti and Nb oxides, which are well-known biocompatible materials.
引用
收藏
页码:1475 / 1485
页数:10
相关论文
共 104 条
[1]  
Sul YT(2005)Optimum surface properties of oxidized implants for reinforcement of osseointegration: surface chemistry, oxide thickness, porosity, roughness, and crystal structure Int J Oral Maxillofac Implants 20 349-359
[2]  
Johansson C(2005)The corrosion and nickel release behavior of laser surface-melted NiTi shape memory alloy in Hanks’ solution Surf Coat Technol 192 347-353
[3]  
Wennerberg A(2012)Effects of anodic oxidation and hydrothermal treatment on surface characteristics and biocompatibility of Ti–30Nb–1Fe–1Hf alloy Appl Surf Sci 258 6190-6198
[4]  
Cho LR(2011)Surface modification of magnetron-sputtered hydroxyapatite thin films via silicon substitution for orthopaedic and dental applications Surf Coat Technol 205 3472-3477
[5]  
Chang BS(2008)The biocompatibility of SLA-treated titanium implants Biomed Mater 3 025011-025017
[6]  
Albrektsson T(1995)Six-year results of hydroxyapatite-coated total hip replacement J Bone Joint Surg-Br 77 534-547
[7]  
Cui ZD(1999)Influence of kerosene and distilled water as dielectrics on the electric discharge machining characteristics of Ti–6A1–4V J Mater Process Tech 87 107-111
[8]  
Man HC(2013)Multi-response optimization of process parameters based on response surface methodology for pure titanium using WEDM process Int J Adv Manuf Technol 68 2645-2668
[9]  
Yang XJ(2009)Investigation of electro-discharge micro-machining of titanium super alloy Int J Adv Manuf Technol 41 1094-1106
[10]  
Ou SF(2012)Simultaneous optimisation of multiple performance characteristics in micro-EDM drilling of titanium alloy Int J Adv Manuf Technol 61 1231-1239