Atlantoaxial fusion using anterior transarticular screw fixation of C1–C2: technical innovation and biomechanical study

被引:0
|
作者
Milan K. Sen
Thomas Steffen
Lorne Beckman
Anthony Tsantrizos
Rudolph Reindl
Max Aebi
机构
[1] McGill University Health Centre,Division of Orthopaedic Surgery
[2] Royal Victoria Hospital,McGill Orthopaedic Research Laboratory
[3] 370 East 69th Street,undefined
[4] Apt. 6E,undefined
来源
European Spine Journal | 2005年 / 14卷
关键词
Atlas; Axis; Fracture; Spinal instability; Transarticular fixation;
D O I
暂无
中图分类号
学科分类号
摘要
This study is an attempt to describe a new technique for anterior transarticular screw fixation of the atlantoaxial joints, and to compare the stability of this construct to posterior transarticular screw fixation with and without laminar cerclage wiring. Nine human cadaveric specimens were included in this study. The C1–C2 motion segment was instrumented using either anterior transarticular screws (group 1), posterior transarticular screws alone (group 2), or posterior screws with interlaminar cerclage wires (group 3). Using an unconstrained mechanical testing machine, the specimens were tested in rotation, lateral bending, and flexion-extension using nondestructive loads of ±2 N m. The specimens were also tested in translation using nondestructive loads of ±100 N. All values for the three groups with regards to anterior-posterior displacement, rotation, and lateral bending were similar as determined using a Kruskal–Wallis rank sum test with a significance level of p<0.05. The only significant difference was registered in flexion-extension where the cerclage wire added some strength to the construct. Anterior transarticular screw fixation of the atlantoaxial spine has several advantages over posterior fixation techniques, and is as stable as posterior transarticular fixation in all clinically significant planes of motion. The addition of posterior interlaminar cerclage wiring further improves resistance to flexion-extension forces. Anterior transarticular screw fixation of the atlantoaxial joint is a useful technique for achieving C1–C2 stabilization.
引用
收藏
页码:512 / 518
页数:6
相关论文
共 50 条
  • [1] Atlantoaxial fusion using anterior transarticular screw fixation of C1-C2: technical innovation and biomechanical study
    Sen, MK
    Steffen, T
    Beckman, L
    Tsantrizos, A
    Reindl, R
    Aebi, M
    EUROPEAN SPINE JOURNAL, 2005, 14 (05) : 512 - 518
  • [2] The Anterior Transarticular Fixation of C1/C2 in the Elderly With Dens Fractures
    Gembruch, Oliver
    Ahmadipour, Yahya
    Lemonas, Elias
    Mueller, Oliver
    INTERNATIONAL JOURNAL OF SPINE SURGERY, 2020, 14 (02) : 162 - 169
  • [3] Biomechanical Effects of Lateral Inclination C1 and C2 Pedicle Screws on Atlantoaxial Fixation
    Zhang, Lei
    Wang, Huan
    ORTHOPAEDIC SURGERY, 2021, 13 (07) : 2027 - 2033
  • [4] Posterior C1-C2 transarticular screw fixation for atlantoaxial arthrodesis
    Dickman, CA
    Sonntag, VKH
    NEUROSURGERY, 1998, 43 (02) : 275 - 280
  • [5] C2 laminar screw and C1-2 transarticular screw combined with C1 laminar hooks for atlantoaxial instability with unilateral vertebral artery injury
    Guo, Qunfeng
    Liu, Jun
    Ni, Bin
    Lu, Xuhua
    Zhou, Fengjin
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2011, 131 (09) : 1207 - 1210
  • [6] Percutaneous anterior C1/2 transarticular screw fixation: salvage of failed percutaneous odontoid screw fixation for odontoid fracture
    Wu, Ai-Min
    Jin, Hai-Ming
    Lin, Zhong-Ke
    Chi, Yong-Long
    Wang, Xiang-Yang
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2017, 12
  • [7] C1 Titanium Cables Combined with C2 Pedicle Screw-Rod Fixation for Atlantoaxial Instability Not Suitable for Placement of C1 Screws
    Zhang, Jie-Hong
    Zhang, Zhi-Jing
    Zhu, Ya
    Shi, Jian-Dong
    Li, Bin
    Lu, Yi-Sheng
    WORLD NEUROSURGERY, 2018, 120 : E453 - E456
  • [8] Clinical Outcome Analysis of Posterior C1 and C2 Screw Rod Fixation (Harms-Goel Technique) in Traumatic Atlantoaxial Dislocation
    Singh, Deepak Kumar
    Agrahari, Vrihaspati Kumar
    Kaif, Md
    Yadav, Kuldeep
    Singh, Rakesh Kumar
    Ahmad, Farhan
    Khan, Khursheed
    Pathak, Vipul
    INDIAN JOURNAL OF NEUROTRAUMA, 2019, 16 (01) : 58 - 62
  • [9] The height for screw index (HSI) predicts the development of C2 nerve dysfunction associated with C1 lateral mass screw fixation for atlantoaxial instability
    Huang, Da-Geng
    Hao, Ding-Jun
    Jiang, Yong-Hong
    Cheng, Yue
    Pan, Jun-Wei
    Qiang, Yong-Qian
    He, Bao-Rong
    Qian, Li-Xiong
    EUROPEAN SPINE JOURNAL, 2014, 23 (05) : 1092 - 1098
  • [10] Novel unilateral C1 double screw and ipsilateral C2 pedicle screw placement combined with contralateral laminar screw-rod fixation for atlantoaxial instability
    Shi, Lei
    Shen, Kai
    Deng, Rui
    Yan, Zheng-Jian
    Liang, Kai-Lu
    Chen, Liang
    Ke, Zhen-Yong
    Deng, Zhong-Liang
    EUROPEAN SPINE JOURNAL, 2019, 28 (02) : 362 - 369