Vascular closure devices: A review of their use after invasive procedures

被引:20
作者
Lasic Z. [1 ,2 ]
Nikolsky E. [1 ]
Kesanakurthy S. [1 ]
Dangas G. [1 ]
机构
[1] Lenox Hill Hospital, Cardiovascular Research Foundation, New York, NY
[2] Cardiovascular Research Foundation, New York, NY 10022
关键词
Percutaneous Coronary Intervention; Closure Device; Mechanical Compression; Manual Compression; Diagnostic Catheterization;
D O I
10.2165/00129784-200505030-00005
中图分类号
学科分类号
摘要
In the endovascular procedure setting, vascular closure devices (VCD) have emerged as an alternative to mechanical compression in order to achieve vascular hemostasis after puncture of the femoral artery. VCD are categorized based primarily on the principle mechanism of hemostasis, which includes biodegradable plug, suture, staples, or ultrasound. While VCD offer advantages over mechanical compression (shorter time to hemostasis and patient ambulation, high rate of patient satisfaction, and greater cost-effectiveness) complications related to the site of femoral access are still present. Efficacy and safety of VCD have been evaluated in a number of clinical trials, but to date there is still a lack of randomized clinical trials with sample sizes large enough to reveal superiority or non-inferiority of VCD compared with mechanical compression. Mechanical compression and VCD are effective and well tolerated in the setting of diagnostic procedures and procedures that do not use anticoagulation. For both methods, success rates are lower, and complication rates higher, in the setting of interventional procedures and when anticoagulation medications are used. Regardless of the device type, deployment failure is the major drawback of VCD. However, overall, meta-analysis data demonstrated that complications and success rates are not significantly different between mechanical compression and VCD. Current data suggest that the correct answer on whether or not to use VCD still remains in the operator domain where integration of clinical data and familiarity with a particular closure device plays a key role in achieving successful hemostasis and avoiding access site complication. © 2005 Adis Data Information BV. All rights reserved.
引用
收藏
页码:185 / 200
页数:15
相关论文
共 73 条
[51]  
Gerckens U., Cattelaens N., Lampe E.G., Et al., Management of arterial puncture site after catheterization procedures: Evaluating a suture-mediated closure device, Am J Cardiol, 83, 12, pp. 1658-1663, (1999)
[52]  
Noguchi T., Miyazaki S., Yasuda S., Et al., A randomised controlled trial of Prostar Plus for haemostasis in patients after coronary angioplasty, Eur J Vasc Endovasc Surg, 19, 5, pp. 451-455, (2000)
[53]  
Rickli H., Unterweger M., Sutsch G., Et al., Comparison of costs and safety of a suture-mediated closure device with conventional manual compression after coronary artery interventions, Catheter Cardiovasc Interv, 57, 3, pp. 297-302, (2002)
[54]  
Kahn Z.M., Kumar M., Hollander G., Et al., Safety and efficacy of the Perclose suture-mediated closure device after diagnostic and interventional catheterizations in a large consecutive population, Catheter Cardiovasc Interv, 55, 1, pp. 8-13, (2002)
[55]  
Nasu K., Tsuchikane E., Sumitsuji S., The clinical effectiveness of the Prostar XL suture mediated percutaneous vascular closure device for achievement of hemostasis in patients following coronary interventions: Results of the Perclose AcceleRated Ambulation and DISchargE (PARADISE) trial, J Invasive Cardiol, 15, 5, pp. 251-256, (2003)
[56]  
Yamaguchi T., Nakamura M., Muramatsu T., Et al., The result of early discharge and economical effectiveness study for new hemostasis device (EDEN) trial, Shinryou Shinyaku, 36, pp. 59-65, (1999)
[57]  
Fram D.B., Giri S., Jamil G., Et al., Suture closure of the femoral arteriotomy following invasive cardiac procedures: A detailed analysis of efficacy, complications, and the impact of early ambulation in 1,200 consecutive, unselected cases, Catheter Cardiovasc Interv, 53, 2, pp. 163-173, (2001)
[58]  
Kornowski R., Brandes S., Teplitsky I., Et al., Safety and efficacy of a 6 French perclose arterial suturing device following percutaneous coronary interven-tions: A pilot evaluation, J Invasive Cardiol, 14, 12, pp. 741-745, (2002)
[59]  
Crocker C.H., Cragun K.T., Timimi F.K., Et al., Immediate ambulation following diagnostic coronary angiography procedures utilizing a vascular closure device (The Closer), J Invasive Cardiol, 14, 12, pp. 728-732, (2002)
[60]  
Eggebrecht H., Naber C., Woertgen U., Et al., Percutaneous suture-mediated closure of femoral access sites deployed through the procedure sheath: Initial clinical experience with a novel vascular closure device, Catheter Cardiovasc Interv, 58, 3, pp. 313-321, (2003)