A new monitoring scheme of an air quality network based on the kernel method

被引:0
作者
Maroua Said
Khaoula ben Abdellafou
Okba Taouali
Mohamed Faouzi Harkat
机构
[1] University of Sousse,Department of Computer Science, Faculty of Computers and Information Technology
[2] National Engineering School of Sousse (ENISO),Department of Computer Engineering, Faculty of Computers and Information Technology
[3] MARS Research Laboratory,Department of Electronics, Faculty of Engineering Annaba
[4] University of Tabuk,undefined
[5] University of Tabuk,undefined
[6] University of Monastir,undefined
[7] National Engineering School of Monastir,undefined
[8] Badji Mokhtar,undefined
来源
The International Journal of Advanced Manufacturing Technology | 2019年 / 103卷
关键词
Air pollution; Air quality; KPLS; Reduced KPLS; SPE; Fault detection;
D O I
暂无
中图分类号
学科分类号
摘要
Air pollution is classified as one of the most dangerous type on the human health, the environment, and the ecosystem. However, air pollution results in climate change and affects people’s health. For a number of years, monitoring the air quality has become a very urgent and necessary topic. Moreover, safety and health have been attracting attention as one of the important topics to evaluate, firstly, the degree of air pollution and predict pollutant concentrations accurately. Then, it is crucial to establish a more scientific air quality monitoring to ensure the quality of life. In this paper, new reduced air quality monitoring is suggested to enhance the Fault Detection (FD) of an air quality monitoring network. Furthermore, a sensor FD procedure based on Reduced Kernel Partial Least Squares (RKPLS) is proposed to monitor an air quality monitoring network. The main contribution of the suggested procedure is to enhance the FD of an air quality monitoring network in terms of computation time and false alarm rate, using just the important latent components, compared to standard Kernel Partial Least Squares (KPLS).
引用
收藏
页码:153 / 163
页数:10
相关论文
共 146 条
[1]  
Harkat MF(2006)An improved PCA scheme for sensor FDI: application to an air quality monitoring network J Process Control 16 625-634
[2]  
Mourot G(2010)A holistic approach for optimal design of air quality monitoring network expansion in an urban area Atmos Environ 44 432-440
[3]  
Gilles R(2017)A new air quality monitoring and early warning system: air quality assessment and air pollutant concentration prediction Environ Res 158 105-117
[4]  
Mofarrah A(1986)Methodology for designing air quality monitoring networks: I. theoretical aspects Environ Monit Assess 6 1-11
[5]  
Husain T(2005)Modeling of environmental four-way data from air quality control Chemom Intell Lab Syst 77 115-121
[6]  
Yang Z(2010)Ground-level ozone in the pearl river delta region: analysis of data from a recently established regional air quality monitoring network Atmos Environ 44 814-823
[7]  
Wang J(2015)Online process monitoring using a new PCMD index Int J Adv Manuf Technol 80 947-957
[8]  
Liu MK(1980)Dynamic model-based techniques for the detection of incidents on freeways IEEE Trans Autom Control 25 347-360
[9]  
Avrin J(2003)A review of process fault detection and diagnosis: Part III: process history based methods Comput Chem Eng 27 327-346
[10]  
Pollack R(2003)Monitoring of quality-relevant and quality-irrelevant blocks with characteristic-similar variables based on self-organizing map and kernel approaches J Process Control 73 103-112