Development and Validation of Robot Patient Equipped with an Inertial Measurement Unit and Angular Position Sensors to Evaluate Transfer Skills of Nurses

被引:0
|
作者
Chingszu Lin
Taiki Ogata
Zhihang Zhong
Masako Kanai-Pak
Jukai Maeda
Yasuko Kitajima
Mitsuhiro Nakamura
Noriaki Kuwahara
Jun Ota
机构
[1] The University of Tokyo,Department of Precision Engineering, Graduate School of Engineering
[2] Tokyo Institute of Technology,School of Computing
[3] The University of Tokyo,Department of Precision Engineering, Graduate School of Engineering
[4] Kanto Gakuin University,Faculty of Nursing
[5] Tokyo Ariake University of Medical and Health Sciences,Faculty of Nursing
[6] Tokyo Ariake University of Medical and Health Sciences,Faculty of Nursing
[7] Tokyo Ariake University of Medical and Health Sciences,Faculty of Nursing
[8] Kyoto Institute of Technology,Department of Advanced Fibro
[9] The University of Tokyo,Science
来源
International Journal of Social Robotics | 2021年 / 13卷
关键词
Robot patient; Nursing education; Human patient simulator; Patient transfer skill;
D O I
暂无
中图分类号
学科分类号
摘要
To more efficiently enhance the patient transfer skills of nursing students, this study aims to integrate a transfer skills evaluation system and a robot patient. The evaluation parameters, namely, the translational acceleration of the waist, rotational speed of the chest, and joint angles of the shoulder, hip, and knee, were selected on the basis of the pre-experimental results obtained with a simulated patient acted by the human individuals. To measure these parameters, inertial measurement unit (IMU) and angular position sensors were installed on the robot patient. An experiment was conducted with four nursing teachers to verify whether the robot patient could distinguish the incorrect methods of the transfer skills, determined to be a common mistake made by the nurses. According to the results, most transfer steps had the same effect on the simulated patient and the robot patient, which demonstrates that the robot patient is a suitable substitute for an actual patient. However, in certain steps, the robot patient was not able to distinguish between the correct and incorrect methods using the chosen parameters owing to the differences being insignificant. These insignificant differences were mostly attributed to the passive joint design of the robot patient.
引用
收藏
页码:899 / 917
页数:18
相关论文
共 2 条
  • [1] Development and Validation of Robot Patient Equipped with an Inertial Measurement Unit and Angular Position Sensors to Evaluate Transfer Skills of Nurses
    Lin, Chingszu
    Ogata, Taiki
    Zhong, Zhihang
    Kanai-Pak, Masako
    Maeda, Jukai
    Kitajima, Yasuko
    Nakamura, Mitsuhiro
    Kuwahara, Noriaki
    Ota, Jun
    INTERNATIONAL JOURNAL OF SOCIAL ROBOTICS, 2021, 13 (05) : 899 - 917
  • [2] Development of Robot Patient Lower Limbs to Reproduce the Sit-to-Stand Movement with Correct and Incorrect Applications of Transfer Skills by Nurses
    Lin, Chingszu
    Ogata, Taiki
    Zhong, Zhihang
    Kanai-Pak, Masako
    Maeda, Jukai
    Kitajima, Yasuko
    Nakamura, Mitsuhiro
    Kuwahara, Noriaki
    Ota, Jun
    APPLIED SCIENCES-BASEL, 2021, 11 (06):