Development of Non-enzymatic Cholesterol Electrochemical Sensor Based on Polyindole/Tungsten Carbide Nanocomposite

被引:0
作者
Shubham Sharma
Preeti Joshi
Sameena Mehtab
Md. Ghulam Haider Zaidi
Kavita Singhal
Tanveer Irshad Siddiqi
机构
[1] G.B. Pant University of Agriculture and Technology,Department of Chemistry, College of Basic Sciences and Humanities
[2] D.I.T University,Department of Chemistry
来源
Journal of Analysis and Testing | 2020年 / 4卷
关键词
Electrochemical sensor; Polyindole; Nanocomposite; Cholesterol; Voltammetric techniques;
D O I
暂无
中图分类号
学科分类号
摘要
Non-enzymatic electrochemical sensor was developed for estimation of low-level cholesterol. Polyindole/tungsten carbide (PIN/WC) nanocomposite was synthesized and used as an electroactive material to develop low-cost modified stainless steel plate electrode (SSPE). Surface morphology of developed electrode was characterized by scanning electron microscopy. Electrochemical behavior of cholesterol was investigated through electron impedance spectroscopy, potentiodynamic polarization and cyclic voltammetry in 1-M KOH electrolytic solution. The quantification of cholesterol was studied by square wave voltammetry and differential pulse voltammetry. The calibration plots between the cholesterol concentration and peak current were in linear relation with limit of detection of 1.23 × 10−6 mol L−1. The overall result reveals that developed PIN/WC/SSPE electrode has excellent performance for trace-level cholesterol estimation and can be further employed for cholesterol monitoring in blood serum samples.
引用
收藏
页码:13 / 22
页数:9
相关论文
共 86 条
  • [1] Nauck M(2000)Is lipoprotein cholesterol a significant indicator of cardiovascular risk Clin Chem 46 436-437
  • [2] März W(2011)High-performance electrochemical biosensor for the detection of total cholesterol Biosens Bioelectron 26 4508-4513
  • [3] Wieland H(1990)Dietary protein as a regulator of lipid metabolism: state of the art and new perspectives J Nutr Sci Vitaminol 36 185-188
  • [4] Ahmadalinezhad A(1994)Flow-injection analysis for total cholesterol with photometric detection Anal Chim Acta 287 59-64
  • [5] Chen A(1997)Electrochemical oxidation of cholesterol catalyzed by cholesterol oxidase with use of an artificial electron mediator Anal Chem 69 2367-2372
  • [6] Beynen AC(1995)Simultaneous assays of glucose, urate, and cholesterol in blood serum by amperometric flow injection analysis Electroanalysis 7 143-146
  • [7] Sugano M(1994)An improved HPLC method to purify erythrocyte cholesterol for estimation of in vivo cholesterol synthesis using the deuterium method Appl Radiat Isotop 45 529-533
  • [8] Krug A(2011)Simultaneous determination of serum lathosterol and cholesterol by semi-micro high-performance liquid chromatography with electrochemical detection J Chromatogr B 879 751-755
  • [9] Göbel R(2001)Amperometric determination of cholesterol in serum using a biosensor of cholesterol oxidase contained within a polypyrrole–hydrogel membrane Anal Chim Acta 448 27-36
  • [10] Kellner R(2006)Electrochemical non-enzymatic glucose sensors Anal Chim Acta 556 46-57