Blood Pressure Screening for Critical Congenital Heart Disease in Neonates

被引:0
作者
Kristi L. Boelke
John S. Hokanson
机构
[1] UnityPoint Health-St. Luke’s,Department of Neonatology
[2] University of Wisconsin Hospitals and Clinics,Division of Pediatric Cardiology, Department of Pediatrics
来源
Pediatric Cardiology | 2014年 / 35卷
关键词
Newborn screening; Pulse oximetry; Congenital heart disease; Blood pressure; Coarctation of the aorta; Interrupted aortic arch;
D O I
暂无
中图分类号
学科分类号
摘要
Pulse oximetry (POx) screening for critical congenital heart disease (CCHD) in neonates is less effective in identifying aortic arch obstruction than in detecting other forms of CCHD. This study was performed to assess the use of neonatal blood pressure (BP) screening to detect CCHD. A retrospective review of BP and POx measurements performed at the age of 24 h or before discharge in asymptomatic term neonates was undertaken. The charts of infants readmitted younger than 30 days with a diagnosis of CCHD also were reviewed to identify infants with a missed diagnosis. The screening process was completed for 10,012 of 10,436 infants. Because of an abnormal initial result, 164 neonates required a repeat screening (139 due to abnormal BP). A total of 12 infants failed the BP screening component, and 1 infant failed both the BP and Pox components. The average final right arm-to-leg BP gradient was 25 mmHg in these 13 babies. For nine infants, CCHD was excluded by echocardiography. Three patients were normal at their 1-year well-child exam, and one patient was lost to follow-up evaluation. No infants were identified who had been discharged home with a missed diagnosis of CCHD. Neonatal BP screening to detect CCHD was responsible for more inappropriately performed screenings, repeated screenings, and screening failures than the POx component of the screening protocol and had a highest possible positive predictive value of 1 in 13. These data suggests that BP screening at the time of routine newborn hospital discharge is of limited value in the detection of unrecognized CCHD.
引用
收藏
页码:1349 / 1355
页数:6
相关论文
共 29 条
[1]  
Aamir T(2007)Delayed diagnosis of critical congenital cardiovascular malformations (CCVM) and pulse oximetry screening of newborns Acta Paediatr 96 1146-1149
[2]  
Kruse L(1993)Routine evaluation of blood pressure, hematocrit, and glucose in newborns Pediatrics 92 474-476
[3]  
Ezeakudo O(2008)Missed diagnosis of critical congenital heart disease Arch Pediatr Adolesc Med 162 969-974
[4]  
Chang RK(2007)Population-based study of antenatal detection of congenital heart disease by ultrasound examination Ultrasound Obstet Gynecol 29 619-624
[5]  
Gurvitz M(2004)Variability of four-limb blood pressure in normal neonates Arch Dis Child Fetal Neonatal Ed 89 F325-F327
[6]  
Rodriguez S(2009)Impact of pulse oximetry screening on the detection of duct-dependent congenital heart disease: a Swedish prospective screening study in 39,821 newborns BMJ 338 a3037-794
[7]  
Chew C(2011)Pulse oximetry screening for congenital heart defects in newborn infants (PulseOx): a test accuracy study Lancet 378 785-570
[8]  
Crossland DS(2014)2014 Recommendations for pediatric preventive health care Pediatrics 133 568-1900
[9]  
de Wahl Granelli A(2002)The incidence of congenital heart disease J Am Coll Cardiol 39 1890-6
[10]  
Ewer AK(2010)Pulse oximetry screening for unrecognized congenital heart disease in neonates Neonatol Today 5 1-382