Application of asymmetric flow field-flow fractionation (AsFlFFF) coupled to inductively coupled plasma mass spectrometry (ICPMS) to the quantitative characterization of natural colloids and synthetic nanoparticles

被引:0
作者
M. Bouby
H. Geckeis
F. W. Geyer
机构
[1] Karlsruhe Institute of Technology,Institut für Nukleare Entsorgung (INE), Forschungszentrum Karlsruhe
来源
Analytical and Bioanalytical Chemistry | 2008年 / 392卷
关键词
Flow field-flow fractionation; Inductively coupled plasma mass spectrometry; Radionuclides; Colloids; Humic acids; Nanoparticles; Quantum dots; Quantification; Hydrodynamic size;
D O I
暂无
中图分类号
学科分类号
摘要
A straightforward quantification method is presented for the application of asymmetric flow field-flow fractionation (AsFlFFF) combined with inductively coupled plasma mass spectrometry (ICPMS) to the characterization of colloid-borne metal ions and nanoparticles. Reproducibility of the size calibration and recovery of elements are examined. Channel flow fluctuations are observed notably after initiation of the fractionation procedure. Their impact on quantification is considered by using 103Rh as internal reference. Intensity ratios measured for various elements and Rh are calculated for each data point. These ratios turned out to be independent of the metal concentration and total sample solution flow introduced into the nebulizer within a range of 0.4–1.2 mL min−1. The method is applied to study the interaction of Eu, U(VI) and Th with a mixture of humic acid and clay colloids and to the characterization of synthetic nanoparticles, namely CdSe/ZnS-MAA (mercaptoacetic acid) core/shell-coated quantum dots (QDs). Information is given not only on inorganic element composition but also on the effective hydrodynamic size under relevant conditions. Detection limits (DLs) are estimated for Ca, Al, Fe, the lanthanide Ce and the natural actinides Th and U in colloid-containing groundwater. For standard crossflow nebulizer, estimated values are 7 × 103, 20, 3 × 102, 0.1, 0.1 and 7 × 10−2 µg L−1, respectively. DLs for Zn and Cd in QD characterization are 28 and 11 µg L−1, respectively.
引用
收藏
页码:1447 / 1457
页数:10
相关论文
共 262 条
  • [1] Bowman MC(2008)undefined J Am Chem Soc 130 6896-6897
  • [2] Ballard TE(1999)undefined Nature 397 56-59
  • [3] Ackerson CJ(2004)undefined Radiochim Acta 92 765-774
  • [4] Feldheim DL(2006)undefined Nuc Eng Technol 38 459-482
  • [5] Margolis DM(2006)undefined Adv Coll Int Sci 119 71-96
  • [6] Melander C(2008)undefined J Environ Monit 10 713-717
  • [7] Kersting AB(2007)undefined Environ Poll 150 5-22
  • [8] Efurd DW(2008)undefined Langmuir 24 6409-6413
  • [9] Finnegan DL(2008)undefined Ecotoxicol 17 287-314
  • [10] Rokop DJ(2008)undefined Ecotoxicol 17 344-361