Effect of corneal astigmatism on intraocular pressure measurement using ocular response analyzer and Goldmann applanation tonometer

被引:0
|
作者
Mana Hagishima
Kazutaka Kamiya
Fusako Fujimura
Tetsuya Morita
Nobuyuki Shoji
Kimiya Shimizu
机构
[1] University of Kitasato School of Medicine,Department of Ophthalmology
[2] University of Kitasato,Kanagawa, and School of Allied Health Sciences
来源
Graefe's Archive for Clinical and Experimental Ophthalmology | 2010年 / 248卷
关键词
Corneal astigmatism; Corneal-compensated IOP; Goldmann-correlated IOP; Goldmann applanation tonometry; Ocular Response Analyzer;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:257 / 262
页数:5
相关论文
共 50 条
  • [21] Changes in corneal biomechanics and intraocular pressure following Femto-LASIK using Goldman applanation tonometry and ocular response analyzer
    Ahmed Yassin Hemida
    Omar M Said
    Asser A.E.Abdel-Meguid
    Mohammed Iqbal
    Amani E Badawi
    International Journal of Ophthalmology, 2020, (05) : 782 - 787
  • [22] Repeatability and Reproducibility of Goldmann Applanation, Dynamic Contour, and Ocular Response Analyzer Tonometry
    Wang, Allen Shawlun
    Alencar, Luciana M.
    Weinreb, Robert N.
    Tafreshi, Ali
    Deokule, Sunil
    Vizzeri, Gianmarco
    Medeiros, Felipe A.
    JOURNAL OF GLAUCOMA, 2013, 22 (02) : 127 - 132
  • [23] Corneal Buckling during Applanation and Its Effect on the Air Pressure Curve in Ocular Response Analyzer
    Jozwik, Agnieszka
    Kasprzak, Henryk
    Kozakiewicz, Agata
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2019, 16 (15)
  • [24] Comparison of intraocular pressure measurements obtained by icare pro tonometer, non-contact tonometer and Goldmann applanation tonometer in healthy individuals
    Duran, M.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2023, 46 (10): : 1195 - 1203
  • [25] Assessment of the Ocular Response Analyzer as a Tool for Intraocular Pressure Measurement
    Elsheikh, Ahmed
    Alhasso, Daad
    Kotecha, Aachal
    Garway-Heath, David
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2009, 131 (08):
  • [26] Effects of central corneal thickness, central corneal power, and axial length on intraocular pressure measurement assessed with goldmann applanation tonometry
    Fatih Özcura
    Sayime Aydın
    Nevin Uzgören
    Japanese Journal of Ophthalmology, 2008, 52 : 353 - 356
  • [27] Effects of central corneal thickness, central corneal power, and axial length on intraocular pressure measurement assessed with goldmann applanation tonometry
    Oezcura, Fatih
    Aydin, Sayime
    Uzgoeren, Nevin
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2008, 52 (05) : 353 - 356
  • [28] Intraocular pressure measured by dynamic contour tonometer and ocular response analyzer in normal tension glaucoma
    Tetsuya Morita
    Nobuyuki Shoji
    Kazutaka Kamiya
    Mana Hagishima
    Fusako Fujimura
    Kimiya Shimizu
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2010, 248 : 73 - 77
  • [29] Intraocular pressure measured by dynamic contour tonometer and ocular response analyzer in normal tension glaucoma
    Morita, Tetsuya
    Shoji, Nobuyuki
    Kamiya, Kazutaka
    Hagishima, Mana
    Fujimura, Fusako
    Shimizu, Kimiya
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2010, 248 (01) : 73 - 77
  • [30] Intraocular pressure measurement with ocular response analyzer over soft contact lens
    Sapkota, Kishor
    Franco, Sandra
    Lira, Madalena
    CONTACT LENS & ANTERIOR EYE, 2014, 37 (06) : 415 - 419