Accuracy of preoperative templating for total hip arthroplasty using the Picture Archiving and Communication System

被引:0
作者
Gohar A. Naqvi
James C. Walsh
Win Htein
William Curtin
机构
[1] University College Hospital,Department of Orthopaedics
[2] Our Lady’s Hospital,Department of Orthopaedics
来源
European Journal of Orthopaedic Surgery & Traumatology | 2010年 / 20卷
关键词
Preoperative templating; Digital radiographs; PACS; Total hip arthroplasty; Accuracy;
D O I
暂无
中图分类号
学科分类号
摘要
Preoperative planning is a key element in total hip arthroplasty. The magnification of pelvic radiographs is variable which can be corrected on digital imaging, by using a calibration marker of known diameter. The aim of this study is to determine the reliability and accuracy of the use of a calibration marker, for preoperative templating, in total hip arthroplasty. We assessed 59 preoperative antero-posterior pelvic radiographs in patients, due to undergo total hip arthroplasty, who previously had a total hip arthroplasty performed on the contralateral side. All radiographs were taken in our radiology department, using a 30 mm steel ball bearing as a calibration marker. The radiograph magnification was corrected using this calibration marker and the diameter of the in situ femoral prosthetic head was then measured and compared with the actual size as documented in the patients previous operative notes. It was noted during the review that in 41 patients, the marker was placed between the thighs and on top of the pelvis in the remaining 18 patients. The accuracy of measurements in group 1 (marker in between thighs) was within a mean of 1.56% (SD 4.78, 95% CI +0.053 to +3.075) of the actual size, as compared to −9.94% (SD 5.07, 95% CI −12.471 to −7.427) in group 2 (marker on top of the pelvis) (Fig. 3). The average magnification in group 1 was 101.56% (92.31–112.72%) and 90.05% (84.29–106.78%) in group 2. It is recommended that the calibration marker should always be placed between the patient’s thighs, allowing it to achieve a more level plane with the hip joint.
引用
收藏
页码:211 / 215
页数:4
相关论文
共 39 条
[1]  
Gonzalez Della Valle A(2005)The precision and usefulness of preoperative planning for cemented and hybrid primary total hip arthroplasty J Arthroplast 20 51-58
[2]  
Slullitel G(1992)Preoperative planning for total hip arthroplasty J Arthroplast 7 403-409
[3]  
Piccaluga F(2002)A simple guide to determine the magnification of radiographs and to improve the accuracy of preoperative templating J Bone Joint Surg Br 84-B 269-272
[4]  
Salvati EA(1998)The value of preoperative planning for total hip arthroplasty J Bone Joint Surg Br 80-B 382-390
[5]  
Knight JL(2004)Treatment protocol for proximal femoral periprosthetic fractures J Bone Joint Surg Am 86 8-16
[6]  
Atwater RD(1989)Femoral fracture during noncemented total hip arthroplasty J Bone Joint Surg Am 71-8 1135-1142
[7]  
Conn KS(1986)A device to measure X-ray magnification in preoperative planning for cementless arthroplasty Clin Orthop 202 302-306
[8]  
Clarke MT(1995)Determination of accuracy of preoperative templating of noncemented femoral prostheses J Arthroplast 10 507-513
[9]  
Hallett JP(2006)Assessment of reproducibility and accuracy in templating hybrid total hip arthroplasty using digital radiographs J Bone Joint Surg Br 88-B 581-585
[10]  
Eggli S(2006)Accurate scaling of digital radiographs of the pelvis J Bone Joint Surg Br 88-B 1508-1512