Flow injection analysis of trace chromium (VI) in drinking water with a liquid waveguide capillary cell and spectrophotometric detection

被引:0
作者
Jian Ma
Dongxing Yuan
Robert H. Byrne
机构
[1] Xiamen University,State Key Laboratory of Marine Environmental Science, College of Environment and Ecology
[2] University of South Florida,College of Marine Science
来源
Environmental Monitoring and Assessment | 2014年 / 186卷
关键词
Liquid waveguide capillary cell; Flow injection analysis; Nanomolar detection limit; Chromium (VI); Drinking water; Spectrophotometry;
D O I
暂无
中图分类号
学科分类号
摘要
Hexavalent chromium (Cr(VI)) is an acknowledged hazardous material in drinking waters. As such, effective monitoring and assessment of the risks posed by Cr(VI) are important analytical objectives for both human health and environmental science. However, because of the lack of highly sensitive, rapid, and simple procedures, a relatively limited number of studies have been carried out in this field. Here we report a simple and sensitive analytical procedure of flow injection analysis (FIA) for sub-nanomolar Cr(VI) in drinking water samples with a liquid core waveguide capillary cell (LWCC). The procedure is based on a highly selective reaction between 1, 5-diphenylcarbazide and Cr(VI) under acidic conditions. The optimized experimental parameters included reagent concentrations, injection volume, length of mixing coil, and flow rate. Measurements at 540 nm, and a 650-nm reference wavelength, produced a 0.12-nM detection limit. Relative standard deviations for 1, 2, and 10 nM samples were 5.6, 3.6, and 0.72 % (n = 9), and the analysis time was <2 min sample−1. The effects of salinity and interfering ions, especially Fe(III), were evaluated. Using the FIA-LWCC method, different sources of bottled waters and tap waters were examined. The Cr(VI) concentrations of the bottled waters ranged from the detection limit to ∼20 nM, and tap waters collected from the same community supply had Cr(VI) concentration around 14 nM.
引用
收藏
页码:367 / 373
页数:6
相关论文
共 61 条
[1]  
Bobrowski A(2009)Characteristics of voltammetric determination and speciation of chromium—a review Electroanalysis 21 1449-1458
[2]  
Krolicka A(1998)Influence of organic ligands on chromium (VI) reduction by iron (II) Environmental Science and Technology 32 2092-2099
[3]  
Zarebski J(2004)Light at the end of the tunnel: recent analytical applications of liquid-core waveguides Trends in Analytical Chemistry 23 385-392
[4]  
Buerge IJ(2008)Determination of total chromium by flame atomic absorption spectrometry after coprecipitation by cerium (IV) hydroxide Environmental Monitoring Assessment 138 167-172
[5]  
Hug SJ(2007)Environmental applications of liquid-waveguide-capillary cells coupled with spectroscopic detection Trends in Analytical Chemistry 26 914-930
[6]  
Dallas T(2006)Chromium determination and speciation since 2000 Trends in Analytical Chemistry 25 1006-1015
[7]  
Dasgupta PK(2000)Chromium occurrence in the environment and methods for its speciation Environmental Pollution 107 262-283
[8]  
Divrikli U(2003)Portable flow-injection analyzer with liquid-core waveguide based fluorescence, luminescence, and long path length absorbance detector Analytica Chimica Acta 479 151-165
[9]  
Soylak M(2012)Flow injection analysis of nanomolar silicate using long pathlength absorbance spectroscopy Talanta 88 484-489
[10]  
Elci L(2009)Reverse flow injection analysis of nanomolar soluble reactive phosphorus in seawater with a long path length liquid waveguide capillary cell and spectrophotometric detection Talanta 78 315-320