Sentinel lymph node identification with radiopharmaceuticals in patients with breast cancer: a comparison of 99mTc-tin colloid and 99mTc-phytate efficiency

被引:0
作者
Ju Won Seok
Yoo Shin Choi
SeMin Chong
Gui Young Kwon
Yun Jae Chung
Beom Gyu Kim
Sung Jun Park
机构
[1] Chung-Ang University,Department of Nuclear Medicine, College of Medicine
[2] Chung-Ang University,Department of General Surgery, College of Medicine
[3] Chung-Ang University,Department of Radiology, College of Medicine
[4] Chung-Ang University,Department of Pathology, College of Medicine
[5] Chung-Ang University,Department of Internal Medicine, College of Medicine
来源
Breast Cancer Research and Treatment | 2010年 / 122卷
关键词
Sentinel node; Breast cancer; Lymphoscintigraphy; Tc-phytate; Tc-tin colloid;
D O I
暂无
中图分类号
学科分类号
摘要
Sentinel lymph node biopsy with lymphoscintigraphy has become the standard method for the detection of axillary lymph node metastasis in breast cancer patients. However, there is no standardized radiopharmaceutical. For the detection of axillary lymph node metastasis by lymphoscintigraphy and sentinel node biopsy in patients with breast cancer, we compared the results between subareolar injection of 99mTc-tin colloid and injection of 99mTc-phytate. This study included 516 breast cancer patients who underwent surgery between 2001 and 2010. Among the 516 patients, 99mTc-tin colloid (37-185 MBq) was administered to 412 patients by subareolar injection, and 99mTc-phytate (37–185 MBq) was injected in 104 patients. Lymphoscintigraphy was performed with the patients in the supine position, and sentinel node identification was performed by hand-held gamma probe during surgery. Among 412 patients with 99mTc-tin colloid, the sentinel node was identified by lymphoscintigraphy in 364 cases (88.3%) and by a gamma probe in 369 cases (89.6%). Among 104 patients with 99mTc-phytate, 101 cases (97.1%) were identified by lymphoscintigraphy and 101 cases (97.1%) were identified by a gamma probe. The identification rates by lymphoscintigraphy and gamma probe were superior with 99mTc-phytate, as compared with 99mTc-tin colloid, with a statistically significant difference (P < 0.05 for both methods). 99mTc-phytate is a better choice than 99mTc-tin colloid for identification of the sentinel node in breast cancer patients.
引用
收藏
页码:453 / 457
页数:4
相关论文
共 79 条
[1]  
Krag D(1998)The sentinel node in breast cancer-a multicenter validation study N Engl J Med 339 941-946
[2]  
Weaver D(2001)Sentinel node biopsy with technetium-99m colloidal rhenium sulphide in patients with breast cancer Br J Surg 88 704-707
[3]  
Ashikaga T(2003)A randomized comparison of sentinel-node biopsy with routine axillary dissection in breast cancer N Engl J Med 349 546-553
[4]  
Moffat F(1977)An approach for the treatment of penile carcinoma Cancer 39 456-466
[5]  
Llimberg VS(1993)Surgical resection and radiolocalization of the sentinel node in breast cancer using a gamma probe Surg Oncol 2 335-339
[6]  
Shiever C(1983)Cutaneous lymphoscintigraphy in malignant melanoma Semin Nucl Med 13 61-69
[7]  
Watanabe T(1989)Preparation and evaluation of Tc-99m hydorxyethyl starch as a potential radiopharmaceutical for lymphoscintigraphy: comparison with Tc-99m human serum albumin, Tc-99m dextran, and Tc-99m sulfur microcolloid Lymphology 22 157-166
[8]  
Kimijima I(1991)Quantitative lymphoscintigraphy using 99Tcm human serum albumin in patients with previously treated uterine cancer Br J Radiol 64 1119-1121
[9]  
Ohtake T(2001)The use of Tc-99m phytate for sentinel node mapping in melanoma, breast cancer, and vulvar cancer: a study of 100 cases Eur J Nucl Med 28 1597-1604
[10]  
Tsuchiya A(1979)Quantitative lymphoscintigraphy I: basic concepts for optimal uptake of radiocolloids in the parasternal lymph nodes of rabbits J Nucl Med 20 1038-1046