Measurement of Pulse Wave Velocity in Fetal Descending Aorta with Dual Doppler Method: a Preliminary Study

被引:0
作者
Eiji Ryo
Michiharu Seto
Keita Yatsuki
Masayoshi Morita
Hideo Kamata
机构
[1] Teikyo University,Department of Obstetrics and Gynecology, School of Medicine
关键词
Fetal blood pressure; Pulse pressure; Pulse wave velocity; Dual Doppler; Ritodrine hydrochloride;
D O I
10.1007/s42399-021-00867-7
中图分类号
学科分类号
摘要
Pulse wave velocity (PWV) reflects blood pulse pressure. We attempted to determine whether commercially marketed ultrasound machine can accurately measure the PWV of the descending aorta of the human fetus. Thirty-two singleton pregnant women participated. Eight women (tocolysis group) were given ritodrine hydrochloride, and the other 24 women (normal group) were not. The descending aorta of the fetus was depicted in the longitudinal direction. Two distant sample volumes were set, and two Doppler waveforms were simultaneously obtained. The distance between the two sample volumes was divided by the time interval between the start of the two waveforms, and a PWV value was obtained. (1) Scatter diagrams for the gestational week and PWV were made, and a linear regression analysis was determined. (2) The PWV for the normal group was compared with the PWV for a group described in a previous report, one measured using ultrasonic phased-tracking. (3) The PWV values in the tocolysis group were compared with those in the normal group. (1) Significant correlations between PWV and gestational weeks were not found. (2) The mean (SE) of the PWV was 2.1 (0.12) m/s, which was similar to the PWV (2.2 (0.069) m/s) measured with ultrasonic phased-tracking. (3) The mean (SE) of the PWV (2.6 (0.25) m/s) in the tocolysis group was larger than that in the normal group (p = 0.032). The PWV of the descending fetal aorta could be accurately and conveniently measured with a commercially marketed ultrasound machine. In addition, PWV measurement with dual Doppler technique had ability to detect fetal cardio-vascular changes by ritodrine infusion.
引用
收藏
页码:1133 / 1136
页数:3
相关论文
共 50 条
[41]   Aortic pulse wave velocity measurement in systemic sclerosis patients [J].
Colaci, M. ;
Giuggioli, D. ;
Manfredi, A. ;
Sebastiani, M. ;
Coppi, F. ;
Rossi, R. ;
Richeldi, L. ;
Ferri, C. .
REUMATISMO, 2012, 64 (06) :360-367
[42]   An innovative numerical approach to resolve the pulse wave velocity in a healthy thoracic aorta model [J].
Yang, An-Shik ;
Wen, Chih-Yung ;
Tseng, Li-Yu ;
Chiang, Chih-Chieh ;
Tseng, Wen-Yih Isaac ;
Yu, Hsi-Yu .
COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2014, 17 (05) :461-473
[43]   A NEW SYSTEM FOR MEASUREMENT OF THE PULSE TRANSIT TIME, THE PULSE WAVE VELOCITY AND ITS ANALYSIS [J].
Bereksi-Reguig, Anes. ;
Bereksi-Reguig, F. ;
Ali, A. Nait .
JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2017, 17 (01)
[44]   A simplified measurement of pulse wave velocity is not inferior to standard measurement in young adults and children [J].
Edgell, Heather ;
Stickland, Michael K. ;
MacLean, Joanna E. .
BLOOD PRESSURE MONITORING, 2016, 21 (03) :192-195
[45]   Accuracy of arterial pulse-wave velocity measurement using MR [J].
Bolster, BD ;
Atalar, E ;
Hardy, CJ ;
McVeigh, ER .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (04) :878-888
[46]   Pulse Wave Velocity Measurement in Healthy and Diseased Carotid Arteries In Vivo [J].
Huang, Chengwu ;
Su, Yuan ;
Zhang, Hong ;
Qian, Lin-Xue ;
Luo, Jianwen .
2015 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2015,
[47]   Measurement of local pulse wave velocity: Effects of signal processing on precision [J].
Hermeling, Evelien ;
Reesink, Koen D. ;
Reneman, Robert S. ;
Hoeks, Arnold P. G. .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2007, 33 (05) :774-781
[48]   Measurement of Local Pulse Wave Velocity using Fast Ultrasound Imaging [J].
Singh, Abhinav Kumar ;
Sahani, Ashish Kumar .
2020 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2020,
[49]   Rapid measurement of pulse wave velocity via multisite flow displacement [J].
Shao, XZ ;
Fei, DY ;
Kraft, KA .
MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (06) :1351-1357
[50]   The effect of measurement position on brachial-ankle pulse wave velocity [J].
Shimawaki, Satoshi ;
Toda, Mai ;
Nakabayashi, Masataka ;
Sakai, Naotaka .
ACTA OF BIOENGINEERING AND BIOMECHANICS, 2015, 17 (01) :111-116