Measurement of Pulse Wave Velocity in Fetal Descending Aorta with Dual Doppler Method: a Preliminary Study

被引:0
作者
Eiji Ryo
Michiharu Seto
Keita Yatsuki
Masayoshi Morita
Hideo Kamata
机构
[1] Teikyo University,Department of Obstetrics and Gynecology, School of Medicine
关键词
Fetal blood pressure; Pulse pressure; Pulse wave velocity; Dual Doppler; Ritodrine hydrochloride;
D O I
10.1007/s42399-021-00867-7
中图分类号
学科分类号
摘要
Pulse wave velocity (PWV) reflects blood pulse pressure. We attempted to determine whether commercially marketed ultrasound machine can accurately measure the PWV of the descending aorta of the human fetus. Thirty-two singleton pregnant women participated. Eight women (tocolysis group) were given ritodrine hydrochloride, and the other 24 women (normal group) were not. The descending aorta of the fetus was depicted in the longitudinal direction. Two distant sample volumes were set, and two Doppler waveforms were simultaneously obtained. The distance between the two sample volumes was divided by the time interval between the start of the two waveforms, and a PWV value was obtained. (1) Scatter diagrams for the gestational week and PWV were made, and a linear regression analysis was determined. (2) The PWV for the normal group was compared with the PWV for a group described in a previous report, one measured using ultrasonic phased-tracking. (3) The PWV values in the tocolysis group were compared with those in the normal group. (1) Significant correlations between PWV and gestational weeks were not found. (2) The mean (SE) of the PWV was 2.1 (0.12) m/s, which was similar to the PWV (2.2 (0.069) m/s) measured with ultrasonic phased-tracking. (3) The mean (SE) of the PWV (2.6 (0.25) m/s) in the tocolysis group was larger than that in the normal group (p = 0.032). The PWV of the descending fetal aorta could be accurately and conveniently measured with a commercially marketed ultrasound machine. In addition, PWV measurement with dual Doppler technique had ability to detect fetal cardio-vascular changes by ritodrine infusion.
引用
收藏
页码:1133 / 1136
页数:3
相关论文
共 50 条
[31]   MR Pulse Wave Velocity Increases With Age Faster in the Thoracic Aorta Than in the Abdominal Aorta [J].
Devos, Daniel G. H. ;
Rietzschel, Ernst ;
Heyse, Catherine ;
Vandemaele, Pieter ;
Van Bortel, Luc ;
Babin, Danilo ;
Segers, Patrick ;
Westenberg, Jos M. ;
Achten, Rik .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 41 (03) :765-772
[32]   Noninvasive measurement of cardiac stroke volume using pulse wave velocity and aortic dimensions: a simulation study [J].
Charles F Babbs .
BioMedical Engineering OnLine, 13
[33]   Measurement variation of aortic pulse wave velocity in the elderly [J].
Sutton-Tyrrell, K ;
Mackey, RH ;
Holubkov, R ;
Vaitkevicius, PV ;
Spurgeon, HA ;
Lakatta, EG .
AMERICAN JOURNAL OF HYPERTENSION, 2001, 14 (05) :463-468
[34]   A Portable Device for the Measurement of Venous Pulse Wave Velocity [J].
Barbagini, Agata ;
Ermini, Leonardo ;
Pertusio, Raffaele ;
Ferraresi, Carlo ;
Roatta, Silvestro .
APPLIED SCIENCES-BASEL, 2022, 12 (04)
[35]   A pulse wave velocity estimation method for a wearable monitoring device: feasibility and preliminary experimental results [J].
Mattesini, Paolo ;
Travagliati, Marco ;
Simeone, Claudio ;
Baldasarre, Leonardo ;
Bart, Stephen ;
Ramalli, Alessandro .
2023 IEEE SENSORS, 2023,
[36]   Is the blood velocity beat-to-beat variation in the descending aorta similar to the arterial pulse pressure variation? [J].
M Feissel ;
JL Teboul ;
A Cariou ;
I Mangin ;
S Darfin ;
O Ruyer ;
JP Faller .
Critical Care, 6 (Suppl 1)
[37]   LONGITUDINAL PRESTRAIN IN MALE ABDOMINAL AORTA FROM PULSE WAVE VELOCITY VIEWPOINT [J].
Horny, Lukas ;
Adamek, Tomas ;
Chlup, Hynek ;
Zitny, Rudolf ;
Gultova, Eva ;
Vesely, Jan .
COMPUTATIONAL PLASTICITY XI: FUNDAMENTALS AND APPLICATIONS, 2011, :757-763
[38]   Measurement of local pulse wave velocity for carotid artery by using an ultrasound-based method [J].
Tang, Chieh-Ju ;
Lee, Po-Yang ;
Chuang, Yi-Hsiang ;
Huang, Chih-Chung .
ULTRASONICS, 2020, 102
[39]   Measurement of pulse wave velocity, augmentation index, and central pulse pressure in atrial fibrillation: a proof of concept study [J].
Caluwe, Rogier ;
De Vriese, An S. ;
Van Vlem, Bruno ;
Verbeke, Francis .
JOURNAL OF THE AMERICAN SOCIETY OF HYPERTENSION, 2018, 12 (08) :627-632
[40]   Measurement of pulse wave velocity using magnetic resonance imaging [J].
Gang, G ;
Mark, P ;
Cockshott, P ;
Foster, J ;
Martin, T ;
Blyth, K ;
Steedman, T ;
Elliott, A ;
Dargie, H ;
Groenning, B .
PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 :3684-3687