Measurement of Pulse Wave Velocity in Fetal Descending Aorta with Dual Doppler Method: a Preliminary Study

被引:0
|
作者
Eiji Ryo
Michiharu Seto
Keita Yatsuki
Masayoshi Morita
Hideo Kamata
机构
[1] Teikyo University,Department of Obstetrics and Gynecology, School of Medicine
关键词
Fetal blood pressure; Pulse pressure; Pulse wave velocity; Dual Doppler; Ritodrine hydrochloride;
D O I
10.1007/s42399-021-00867-7
中图分类号
学科分类号
摘要
Pulse wave velocity (PWV) reflects blood pulse pressure. We attempted to determine whether commercially marketed ultrasound machine can accurately measure the PWV of the descending aorta of the human fetus. Thirty-two singleton pregnant women participated. Eight women (tocolysis group) were given ritodrine hydrochloride, and the other 24 women (normal group) were not. The descending aorta of the fetus was depicted in the longitudinal direction. Two distant sample volumes were set, and two Doppler waveforms were simultaneously obtained. The distance between the two sample volumes was divided by the time interval between the start of the two waveforms, and a PWV value was obtained. (1) Scatter diagrams for the gestational week and PWV were made, and a linear regression analysis was determined. (2) The PWV for the normal group was compared with the PWV for a group described in a previous report, one measured using ultrasonic phased-tracking. (3) The PWV values in the tocolysis group were compared with those in the normal group. (1) Significant correlations between PWV and gestational weeks were not found. (2) The mean (SE) of the PWV was 2.1 (0.12) m/s, which was similar to the PWV (2.2 (0.069) m/s) measured with ultrasonic phased-tracking. (3) The mean (SE) of the PWV (2.6 (0.25) m/s) in the tocolysis group was larger than that in the normal group (p = 0.032). The PWV of the descending fetal aorta could be accurately and conveniently measured with a commercially marketed ultrasound machine. In addition, PWV measurement with dual Doppler technique had ability to detect fetal cardio-vascular changes by ritodrine infusion.
引用
收藏
页码:1133 / 1136
页数:3
相关论文
共 50 条
  • [1] Simultaneous recordings of pulsed wave Doppler signals in hepatic vein and descending aorta using dual Doppler: a novel method for evaluating fetal arrhythmias
    Kaji, T.
    Maeda, K.
    Suto, M.
    Sato, M.
    Irahara, M.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2012, 39 (03) : 357 - 359
  • [2] NEW METHOD FOR NON-INVASIVE MEASUREMENT OF PULSE-WAVE VELOCITY IN AORTA USING DOPPLER SONOGRAPHY
    LOHR, E
    GOBBLER, T
    SEILER, I
    REIDEMEISTER, JC
    HERZ KREISLAUF, 1977, 9 (03): : 130 - 134
  • [3] Doppler ultrasound in the measurement of pulse wave velocity: agreement with the Complior method
    Calabia, Jordi
    Torguet, Pere
    Garcia, Maria
    Garcia, Isabel
    Martin, Nadia
    Guasch, Bernat
    Faur, Diana
    Valles, Marti
    CARDIOVASCULAR ULTRASOUND, 2011, 9
  • [4] Doppler ultrasound in the measurement of pulse wave velocity: agreement with the Complior method
    Jordi Calabia
    Pere Torguet
    Maria Garcia
    Isabel Garcia
    Nadia Martin
    Bernat Guasch
    Diana Faur
    Martí Vallés
    Cardiovascular Ultrasound, 9
  • [5] MEASUREMENT OF INTERNAL DIAMETER CHANGES AND PULSE WAVE VELOCITY IN FETAL DESCENDING AORTA USING THE ULTRASONIC PHASED-TRACKING METHOD IN NORMAL AND GROWTH-RESTRICTED FETUSES
    Miyashita, Susumu
    Murotsuki, Jun
    Muromoto, Jin
    Ozawa, Katsusuke
    Yaegashi, Nobuo
    Hasegawa, Hideyuki
    Kanai, Hiroshi
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (05): : 1311 - 1319
  • [6] PULSED WAVE DOPPLER VELOCIMETRY IN THE DESCENDING AORTA OF CHRONICALLY INSTRUMENTED FETAL SHEEP
    HUNEKE, B
    SCHRODER, HJ
    CARSTENSEN, MH
    LEICHTWEISS, HP
    JOURNAL OF PERINATAL MEDICINE, 1990, 18 (04) : 245 - 254
  • [7] Noninvasive Method for Measuring Local Pulse Wave Velocity by Dual Pulse Wave Doppler: In Vitro and In Vivo Studies
    Wang, Zhen
    Yang, Yong
    Yuan, Li-jun
    Liu, Jie
    Duan, Yun-you
    Cao, Tie-sheng
    PLOS ONE, 2015, 10 (03):
  • [8] INTRODUCTION OF A NEW METHOD TO ASSESS PULSE WAVE VELOCITY IN THE AORTIC ARCH: DUAL GATE DOPPLER STUDY
    Antonini-Canterin, F.
    Pepe, A.
    Schiavone, A.
    Giorgio, D.
    Strazzanti, M.
    Penzo, M.
    Luzza, G.
    Rivaben, D.
    Nicolosi, E.
    Pagliani, L.
    Piaser, P.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2020, 22 (0G) : G191 - G192
  • [9] Assessment of the severity of aortic regurgitation with pulsed wave Doppler velocity profile in the descending aorta
    Kalayci, Belma
    Kalayci, Suleyman
    Bayir, Pinar Turker
    Duyuler, Serkan
    Guven, Saadet
    Sen, Taner
    Tufekcioglu, Omac
    ANADOLU KARDIYOLOJI DERGISI-THE ANATOLIAN JOURNAL OF CARDIOLOGY, 2014, 14 (05): : 427 - 433
  • [10] The prognostic value of Doppler measurements in fetal descending aorta in conjunction with fetal pulse oximetry recordings during labor
    Kassanos, D.
    Loghis, C.
    Vasios, G.
    Hintipas, E.
    Bournas, N.
    Kallinteri, C.
    Thomopoulos, P.
    Salabasis, C.
    Salarnalekis, E.
    PROCEEDINGS OF THE 8TH WORLD CONGRESS OF PERINATAL MEDICINE, 2007, : 517 - 520