What is the role of contrast-enhanced ultrasound in the evaluation of the endoleak of aortic endoprostheses? A comparison between CEUS and CT on a widespread scale

被引:27
作者
David E. [1 ]
Cantisani V. [2 ]
Grazhdani H. [3 ]
Di Marzo L. [5 ]
Venturini L. [5 ]
Fanelli F. [2 ]
Di Segni M. [2 ]
Di Leo N. [2 ]
Brunese L. [6 ]
Calliada F. [7 ]
Ciccariello M. [2 ]
Bottari A. [1 ]
Ascenti G. [1 ]
D’Ambrosio F. [2 ]
机构
[1] Department of Biomedical Sciences and Morphological and Functional Imaging, University of Messina, Via Consolare Valeria 1, Messina
[2] Department of Radiology, Oncology, and Anatomo Pathology, “Sapienza” University of Rome, Rome
[3] Poliambulatorio Roma, Eur Piazza Guglielmo Marconi 12, Rome
[4] Department of Surgery Pietro Valdoni, Sapienza University, Rome
[5] Department of Medicine and Health Sciences, University of Molise, Contrada Tappino, Campobasso
[6] University Hospital of Pavia, Viale Camillo Golgi 19, Pavia
关键词
Contrast-enhanced ultrasound; CT; Endoleak;
D O I
10.1007/s40477-016-0222-5
中图分类号
学科分类号
摘要
Objective: To evaluate the accuracy of contrast-enhanced ultrasound (CEUS) in comparison to CT angiography (CTA) to identify and classify endoleaks following abdominal aortic aneurism repair with endoprosthesis. Materials and methods: A retrospective analysis of 181 patients treated with EVAR, from September 2009 to September 2014, was performed. Patients were evaluated with CEUS, CTA and angiography in the cases requiring treatment. Sac diameter, sac integrity, identification and classification of endoleaks were taken into consideration. Sensitivity, specificity, accuracy and negative predictive values were considered for each modality of endoleak identification. Results: Forty-two endoleaks (23.2%; type II: 39 cases, type III: 3 cases) were documented. Sensitivity and specificity of CEUS and CT were, respectively, 97.6 and 90.5, 100 and 100%. In two cases, CEUS was able to better classify endoleaks compared to CT. Conclusions: CEUS accuracy to identify endoleaks following EVAR is similar to CT. CEUS should be considered as an effective modality for the long-term surveillance of EVAR because of its capability to correctly classify endoleaks with no ionizing radiation exposure. © 2016, Società Italiana di Ultrasonologia in Medicina e Biologia (SIUMB).
引用
收藏
页码:281 / 287
页数:6
相关论文
共 33 条
[1]  
Greenhalgh R.M., Brown L.C., Powell J.T., Et al., Endovascular versus open repair of abdominal aortic aneurysm, N Engl J Med, 362, 20, pp. 1863-1871, (2010)
[2]  
Biancari F., Catania A., D'Andrea V., Elective endovascular vs. open repair for abdominal aortic aneurysm in patients aged 80 years and older: systematic review and meta-analysis, Eur J Vasc Endovasc Surg, 42, 5, pp. 571-576, (2011)
[3]  
Cao P., De Rango P., Verzini F., Parlani G., Endoleak after endovascular aortic repair: classification, diagnosis and management following endovascular thoracic and abdominal aortic repair, J Cardiovasc Surg, 51, 1, pp. 53-69, (2010)
[4]  
Mehta M., Sternbach Y., Taggert J.B., Long-term outcomes of secondary procedures after endovascular aneurysm repair, J Vasc Surg, 52, 6, pp. 1442-1449, (2010)
[5]  
Corriere M.A., Feurer I.D., Becker S.Y., Endoleak following endovascular abdominal aortic aneurysm repair: implications for duration of screening, Ann Surg, 239, 6, pp. 800-805, (2004)
[6]  
Raman K.G., Missig-Carroll N., Richardson T., Muluk S.C., Makaroun M.S., Color-flow duplex ultrasound scan versus computed tomographic scan in the surveillance of endovascular aneurysm repair, J Vasc Surg, 38, 4, pp. 645-651, (2003)
[7]  
Manning B.J., O'Neill S.M., Haider S.N., Duplex ultrasound in aneurysm surveillance following endovascular aneurysm repair: a comparison with computed tomography aortography, J Vasc Surg, 49, 1, pp. 60-65, (2009)
[8]  
Carrafiello G., Lagana D., Recaldini C., Comparison of contrast-enhanced ultrasound and computed tomography in classifying endoleaks after endovascular treatment of abdominal aorta aneurysms: preliminary experience, Cardiovasc Intervent Radiol, 29, 6, pp. 969-974, (2006)
[9]  
Dill-Macky M.J., Wilson S.R., Sternbach Y., Kachura J., Lindsay T., Detecting endoleaks in aortic endografts using contrast-enhanced sonography, AJR Am J Roentgenol, 188, 3, pp. W262-W268, (2007)
[10]  
van der Laan M.J., Bartels L.W., Viergever M.A., Et al., Computed tomography versus magnetic resonance imaging of endoleaks after EVAR, Eur J Vasc Endovasc Surg, 32, 4, pp. 361-365, (2006)