Effects of the hinge position and suction on flow separation and aerodynamic performance of the NACA 0012 airfoil

被引:4
作者
Esmaeel Fatahian
Ali Lohrasbi Nichkoohi
Hesamoddin Salarian
Jahanfar Khaleghinia
机构
[1] Islamic Azad University,Department of Mechanical Engineering, Nour Branch
[2] Islamic Azad University,Department of Mechanical Engineering, Nowshahr Branch
来源
Journal of the Brazilian Society of Mechanical Sciences and Engineering | 2020年 / 42卷
关键词
Flow separation; Suction; Lift coefficient; Drag coefficient; NACA 0012; Hinge position;
D O I
暂无
中图分类号
学科分类号
摘要
In the present study, the effect of hinge position (H) has been numerically investigated to find the appropriate position for improving the aerodynamic performance of the NACA 0012 flapped airfoil. In addition, perpendicular and tangential suctions have been applied to control the flow separation and enhance the aerodynamic performance over the NACA 0012 flapped airfoil at each different hinge positions. The simulations were carried out at a Reynolds number of 5 × 105 (Ma = 0.021) based on two-dimensional incompressible unsteady Reynolds-averaged Navier–Stokes calculations to determine the adequate hinge position. The turbulence was modeled using the shear stress transport k–ω turbulence model. The effect of perpendicular suction (θjet = − 90°) and tangential suction (θjet = − 30°) was computationally studied over NACA 0012 flapped airfoil for five different hinge positions (H = 0.7c, 0.75c, 0.8c, 0.85c and 0.9c) and a flap deflection (δf) of 15°. Based on the results, the hinge position significantly affects the aerodynamic performance of the airfoil. The lift coefficient increased clearly as the hinge position moved to the trailing edge of the airfoil. Using perpendicular suction caused to increase the lift coefficient and decrease the drag coefficient. Consequently, the maximum value of the lift-to-drag ratio (CL/CD) for perpendicular and tangential suctions was achieved about 35.8% and 25.1% higher than that of the case without suction at an angle of attack of 12° and H = 0.9c. Also, the effect of perpendicular suction was more considerable compared to the tangential suction. This caused a reduction in the size of the recirculation zone from 0.5 to 0.09 of the airfoil chord length and also transferred it from 1.13 to 1.18 of the airfoil chord length.
引用
收藏
相关论文
共 114 条
  • [21] Cattafesta LN(2011)Performance of transition model for predicting low Re aerofoil flows without/with single and simultaneous blowing and suction Eur J Mech B Fluids 30 218-1494
  • [22] Sheplak M(2017)Suction control of laminar separation bubble over an airfoil at low Reynolds number Proc Inst Mech Eng G J Aerosp Eng 156 274-479
  • [23] Yang L(2017)The effects of Mach number on the flow separation control of an airfoil with a small plate near the leading edge Comput Fluids 232 1515-65
  • [24] Li J(2018)Research of the suction flow control on wings at low Reynolds numbers Proc Inst Mech Eng G J Aerosp Eng 50 1481-12
  • [25] Cai J(2015)Three-dimensional suction flow control and suction jet length optimization of NACA 0012 wing Meccanica 195 466-165
  • [26] Wang G(2019)Effects of leading edge defects on aerodynamic performance of the S809 airfoil Energy Convers Manag 45 50-421
  • [27] Zhang Z(2014)Tangential synthetic jets for separation control J Fluids Struct 4 40-1114
  • [28] Svorcan JM(2019)Unsteady RANS simulations of strong and weak 3D stall cells on a 2D pitching aerofoil Fluids 1 1-97
  • [29] Fotev VG(2009)Aerodynamic characteristics of NACA 4412 airfoil section with flap Int J Nav Archit Ocean Eng 789 127-1605
  • [30] Petrović NB(2016)Exponential roughness layer and analytical model for turbulent boundary layer flow over rectangular-prism roughness elements J Fluid Mech 23 412-77