Prospective, multireader evaluation of image quality and vascular delineation of multislice CT angiography of the brain

被引:0
|
作者
Birgit B. Ertl-Wagner
Roland Bruening
Jeffrey Blume
Ralf-Thorsten Hoffmann
Brad Snyder
Karin A. Herrmann
Maximilian F. Reiser
机构
[1] University of Munich,Institute of Clinical Radiology, Klinikum Grosshadern
[2] University of Munich,Institute of Neuroradiology, Klinikum Grosshadern
[3] Brown University,Center for Statistical Sciences
来源
European Radiology | 2005年 / 15卷
关键词
Multislice CT; CT angiography; Central nervous system; Brain;
D O I
暂无
中图分类号
学科分类号
摘要
The aim of this prospective, multireader trial was to investigate image quality and vascular delineation of cranial multislice CT angiography (MSCTA) to identify strengths and weaknesses of the method. Sixty consecutive patients underwent standardized cranial MSCTA. The mean estimated effective dose was 0.96±0.11 mSv. Three masked readers independently graded image quality parameters and vascular delineation on a 5-point scale. Vascular attenuation values and dose-length products were assessed quantitatively. Quantitative parameters were evaluated with a proportional odds regression model with bootstrapped standard errors to adjust the relevant standard errors for correlation within subjects and across readers. The non-parametric Wilcoxon sign-rank test was applied for quantitative measurements. Good to excellent ratings were observed regarding image quality parameters and vascular delineation. The delineation of veins was rated higher than that of arteries (OR 2.00). Smaller arterial segments were rated significantly less favorably than larger segments (OR up to 26.98). Moreover, the cavernous sinus, the C2 segment of the ICA and the communicating arteries demonstrated lower scores. Attenuation values were >240 HU and vessel-to-parenchyma ratios >7 in all vessels. Cranial MSCTA achieved high ratings regarding image quality and vascular delineation. Relative weaknesses were found in small arterial subsegments and in vessels in close topographical proximity to bone.
引用
收藏
页码:1051 / 1059
页数:8
相关论文
共 50 条
  • [21] CT angiography of pulmonary embolism in patients with underlying respiratory disease: impact of multislice CT on image quality and negative predictive value
    Remy-Jardin, M
    Tillie-Leblond, I
    Szapiro, D
    Ghaye, B
    Cotte, L
    Mastora, I
    Delannoy, V
    Remy, J
    EUROPEAN RADIOLOGY, 2002, 12 (08) : 1971 - 1978
  • [22] Dynamic 4D MR angiography versus multislice CT angiography in the evaluation of vascular hepatic involvement in hereditary haemorrhagic telangiectasia
    Scardapane, A.
    Ianora, A. Stabile
    Sabba, C.
    Moschetta, M.
    Suppressa, P.
    Castorani, L.
    Angelelli, G.
    RADIOLOGIA MEDICA, 2012, 117 (01): : 29 - 45
  • [23] Prospective Multireader Evaluation of Photon-counting CT for Multiple Myeloma Screening
    Schwartz, Fides R.
    Vinson, Emily N.
    Spritzer, Charles E.
    Colglazier, Roy
    Samei, Ehsan
    French, Robert J.
    Said, Nicholas
    Waldman, Leah
    McCrum, Erin
    RADIOLOGY-IMAGING CANCER, 2022, 4 (06):
  • [24] Multislice CT coronary angiography: Evaluation of an automatic vessel detection tool
    Dewey, M
    Schnapauff, D
    Laule, M
    Lembcke, A
    Borges, AC
    Rutsch, W
    Hamm, B
    Rogalla, P
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (04): : 478 - 483
  • [25] Preoperative evaluation of live renal donors using multislice CT angiography
    Johnson, JE
    Loveday, EJ
    Archer, LJ
    Lear, P
    Thornton, MJ
    CLINICAL RADIOLOGY, 2005, 60 (07) : 771 - 777
  • [26] Multislice CT of the pelvis:: Dose reduction with regard to image quality
    Wedegärtner, U
    Lorenzen, M
    Lorenzen, J
    Nolte-Ernsting, C
    Weber, C
    Dieckmann, C
    Cramer, M
    Schoder, V
    Adam, G
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (01): : 106 - 112
  • [27] The usefulness of a prospective ECG gated CT angiography by 256 MDCT: feasibility and image quality
    Gu, B. S.
    Bae, G. D.
    Dae, C. M.
    Min, G. H.
    Chun, E. J.
    Choi, S. I.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2011, 13 (0A) : A70 - A70
  • [29] Evaluation of image quality on low contrast media with deep learning image reconstruction algorithm in prospective ECG-triggering coronary CT angiography
    Yuan, Dian
    Wang, Luotong
    Lyu, Peijie
    Zhang, Yonggao
    Gao, Jianbo
    Liu, Jie
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2024, 40 (06): : 1377 - 1388
  • [30] Extension and evaluation of image reconstruction algorithm for multislice helical CT
    Taguchi, K
    RADIOLOGY, 1998, 209P : 283 - 284