Impact of prosthesis-patient mismatch on late outcomes after bioprosthetic mitral valve replacement for mitral regurgitation

被引:0
作者
Yuichiro Kitada
Mamoru Arakawa
Homare Okamura
Kei Akiyoshi
Daijiro Hori
Naoyuki Kimura
Atsushi Yamaguchi
机构
[1] Saitama Medical Center,Department of Cardiovascular Surgery
[2] Jichi Medical University,undefined
来源
Journal of Artificial Organs | 2022年 / 25卷
关键词
Bioprosthetic mitral valve; Prosthesis-patient mismatch; Mitral valve replacement;
D O I
暂无
中图分类号
学科分类号
摘要
Negative impact of prosthesis-patient mismatch on long-term survival after valve replacement has been reported. However, the effect of prosthesis-patient mismatch after bioprosthetic mitral valve replacement has not yet been well examined. The purpose of this study was to investigate the effect of prosthesis-patient mismatch on late outcomes after bioprosthetic mitral valve replacement for mitral regurgitation. A total of 181 patients underwent bioprosthetic mitral valve replacement between April 2008 and December 2016. After excluding patients with mitral stenosis and those with incomplete data, 128 patients were included in the study. Postoperative transthoracic echocardiography was performed before discharge for all patients and the effective orifice area of bioprosthetic mitral valve was calculated using the formula: 220/pressure half-time, and the effective orifice area index was calculated by the formula: effective orifice area/body surface area. Prosthesis-patient mismatch was defined as a postoperative effective orifice area index ≤ 1.2 cm2/m2. The characteristics and outcomes were compared between the groups. There were 34 patients (26.6%) with prosthesis-patient mismatch and 94 patients (73.4%) without prosthesis-patient mismatch. There were no significant differences in the in-hospital mortality and morbidities. Multivariable analysis showed that prosthesis-patient mismatch was an independent predictor of late mortality (hazard ratio 3.38; 95% confidence interval 1.69–6.75; p = 0.001) and death from heart failure (hazard ratio 31.03, 95% confidence interval 4.49–214.40, p < 0.001). Prosthesis-patient mismatch at discharge after mitral valve replacement for mitral regurgitation was associated with long-term mortality and death from heart failure.
引用
收藏
页码:132 / 139
页数:7
相关论文
共 53 条
  • [1] Rahimtoola SH(1978)The problem of valve prosthesis-patient mismatch Circulation 58 20-24
  • [2] Hong S(2013)Effect of the prosthesis-patient mismatch on long-term clinical outcomes after isolated aortic valve replacement for aortic stenosis: a prospective observational study J Thorac Cardiovasc Surg 146 1098-1104
  • [3] Yi G(2017)Impact of prosthesis-patient mismatch on short-term outcomes after aortic valve replacement: a retrospective analysis in East China J Cardiothorac Surg 12 42-227
  • [4] Youn YN(2000)Small valve area index: its influence on early mortality after mitral valve replacement Eur J Cardiothorac Surg 17 222-283
  • [5] Guo L(2004)Late incidence and predictors of persistent or recurrent heart failure in patients with mitral prosthetic valves J Thorac Cardiovasc Surg 128 278-1473
  • [6] Zheng J(2007)The impact of patient prosthesis mismatch on late outcomes after mitral valve replacement J Thorac Cardiovasc Surg 133 1464-1425
  • [7] Chen L(2007)Impact on prosthesis-patient mismatch on survival after mitral valve replacement Circulation 115 1417-1141
  • [8] Yazdanbakhsh AP(2008)Effect of prosthesis-patient mismatch on long-term survival with mitral valve replacement: assessment to 15 years Ann Thorac Surg 87 1135-1081
  • [9] van den Brink RB(2011)Impact of prosthesis patient mismatch after mitral valve replacement: a multicenter analysis of early outcomes and midterm survival Heart 97 1074-1210
  • [10] Dekker E(2010)Factors affecting survival after mitral valve replacement in patients with prosthesis-patient mismatch Ann Thorac Surg 90 1202-1408