Analytical Formula for Load-Carrying Capacity of Eccentrically Loaded CFDT Columns and Performance Comparison with CFST Columns Under Seismic Loads

被引:0
作者
Saeed Asadollahi
Mojtaba Labibzadeh
Farhad Hosseinlou
Amin Khajehdezfuly
机构
[1] Shahid Chamran University of Ahvaz,Faculty of Civil Engineering and Architecture
来源
Iranian Journal of Science and Technology, Transactions of Civil Engineering | 2023年 / 47卷
关键词
Concrete-filled double-tube column; Composite tall structures; Confinement factor; Eccentric axial load capacity; Parametric study;
D O I
暂无
中图分类号
学科分类号
摘要
Concrete-filled double-tube (CFDT) columns are a new idea in designing and building structures. In this manuscript, the effect of various parameters (yield stress of the steel tube, the characteristic strength of concrete, the arrangement of steel tubes, and the ratio of the diameter to the thickness of the steel tubes) on the bearing capacity of eccentrically loaded CFDT columns is studied for the first time. Using ABAQUS software, the finite element model is validated based on available laboratory specimens. The bearing capacity of eccentrically loaded CFDT columns with different material and mechanical specifications is compared in the form of P-M diagrams. The results show that by increasing the yield stress of the outer tube, increasing the diameter of the outer tube and increasing the strength of the outer concrete, the bearing capacity of the CFDT column is increased. Based on the failure modes of the CFDT column under the eccentric load, the outer concrete has the most damage in the tension and compression mode. In addition, the ductility and energy absorption capacity are compared between the CFDT and the concrete-filled steel tube (CFST) columns. Based on this comparison, the performance of the CFDT column is better under eccentric loading. Finally, a formula for designing and determining the bearing capacity of eccentrically loaded CFDT columns is proposed. In the last part of the work, the seismic performance of multi-story buildings equipped with the CFDT and CFST columns under a real earthquake is examined. In terms of seismic performance, the frames equipped with the CFDT columns have more energy absorption and base shear than the frames equipped with the CFST columns. Also, the displacement of the roof related to the bending frame with CFDT columns is less than the frame with CFST columns. The results indicate that CFDT columns improve the seismic performance of tall buildings.
引用
收藏
页码:3033 / 3054
页数:21
相关论文
共 77 条
  • [1] Ahmed M(2019)Behavior of eccentrically loaded double circular steel tubular short columns filled with concrete Eng Struct 201 109790-15
  • [2] Al-Ani YR(2018)Finite element study to address the axial capacity of the circular concrete-filled steel tubular stub columns Thin-Walled Struct 126 2-18
  • [3] Asteris PG(2021)Evaluation of the ultimate eccentric load of rectangular CFSTs using advanced neural network modeling Eng Struct 248 14-919
  • [4] Chaudhari S(2012)Modeling of concrete for nonlinear analysis using finite element code ABAQUS Int J Comput Appl 44 901-431
  • [5] Chakrabarti M(2017)Study on axial compressive capacity of FRP-confined concrete-filled steel tubes and its comparisons with other composite structural systems Int J Polym Sc 25 417-114
  • [6] Deng J(2020)Numerical investigation for the behaviour of stiffened circular concrete filled double tube columns Structures 191 99-36
  • [7] Ghannam M(2019)Axial compression capacity of circular CFST columns transversely strengthened by FRP Eng Struct 16 24-890
  • [8] Metwally IM(2016)Ultimate capacity prediction of axially loaded CFST short columns Int J Steel Struct 45 876-191
  • [9] Güneyisi EM(2007)Performance of concrete-filled thin-walled steel tubes under pure torsion Thin-Walled Struct 67 177-256
  • [10] Nour AI(2011)Performance of circular CFST column to steel beam frames under lateral cyclic loading J Constr Steel Res 10 04018201-1182