Continuous glucose monitoring in type 1 diabetes

被引:0
作者
Nelly Mauras
Larry Fox
Kimberly Englert
Roy W. Beck
机构
[1] Nemours Children’s Clinic,
[2] Jaeb Center for Health Research,undefined
来源
Endocrine | 2013年 / 43卷
关键词
Continuous glucose sensors; Adolescents; Children; Diabetes control; Quality of life;
D O I
暂无
中图分类号
学科分类号
摘要
Continuous glucose monitors (CGM), devices that can measure interstitial glucose in “real time,” have become widely available particularly for use in patients with diabetes, and their accuracy and ease of use have greatly improved over the last decade. A number of large and well-controlled clinical trials have firmly established their usefulness in improving metabolic control (as measured by HbA1C) and decreasing time spent in hypoglycemia in adults; however, data have been less robust proving benefit in children and adolescents. Benefits are clearly linked to near-continuous wear. Insulin dosing algorithms based on CGM glucose trends have proven useful in dissecting the large volume of data generated daily by these devices, although these are imperfect tools, particularly in children. The technology is likely to be most useful when integrated with insulin pump delivery systems (sensor augmented). In this review, we concentrate on the analysis of published results of the largest trials in adults and children, including the very young, with diabetes.
引用
收藏
页码:41 / 50
页数:9
相关论文
共 286 条
[1]  
Weinzimer SA(2005)Accuracy of newer-generation home blood glucose meters in a diabetes research in children network (DirecNet) inpatient exercise study Diabetes Technol. Ther. 7 675-680
[2]  
Beck RW(2011)Glycaemic control in type 1 diabetes during real time continuous glucose monitoring compared with self monitoring of blood glucose: meta-analysis of randomised controlled trials using individual patient data BMJ 343 d3805-228
[3]  
Chase HP(2012)Use of continuous glucose monitoring in children and adolescents Pediatr. Diabetes 13 215-2979
[4]  
Fox LA(2011)Continuous glucose monitoring: an endocrine society clinical practice guideline J. Clin. Endocrinol. Metab. 96 2968-1476
[5]  
Buckingham BA(2008)Continuous glucose monitoring and intensive treatment of type 1 diabetes N. Engl. J. Med. 359 1464-147
[6]  
Tamborlane WV(2008)Use of the DirecNet applied treatment algorithm (data) for diabetes management with a real-time continuous glucose monitor (the freestyle navigator) Pediatr. Diabetes 9 142-2049
[7]  
Kollman C(2009)Sustained benefit of continuous glucose monitoring on A1c, glucose profiles, and hypoglycemia in adults with type 1 diabetes Diabetes Care 32 2047-320
[8]  
Coffey J(2010)Effectiveness of sensor augmented insulin pump therapy in type 1 diabetes N. Engl. J. Med. 363 311-774
[9]  
Xing D(2010)Continuous subcutaneous insulin infusion (CSII) versus multiple insulin injections for type 1 diabetes mellitus Cochr. Datab. Syst. Rev. 1 CD005103-800
[10]  
Ruedy KJ(2008)Severe hypoglycaemia and glycaemic control in type 1diabetes: meta-analysis of multiple daily insulin injections compared with continuous subcutaneous insulin infusion Diabet. Med. 25 765-1257