Provisioning a generic simple linear mathematical model for Paranoid and Healthy cases leading to auxiliary investigation of the neuroleptic drugs effect imposed on cardiac output (CO) and blood pressure (BP). Multi-input single output system identification in consistency with the Z-Transform is considered an essential role in the exploration of linear discrete system identification. Twenty Paranoid and 20 Healthy peer cases have been chosen to lie under study. The generated CO model forming two poles and two zeros produced a root–mean-squared error (RMSE) of 0.109 and an average RMSE of 1.39 due to Paranoid cases. On the other hand, Healthy cases obtained model held three poles and two zeros with RMSE equal to 0.17 and an average of 0.63. The BP model with four poles and two zeros showed a 2.15 and 21.69 for RMSE and an average RMSE, respectively, for Paranoid cases, whereas seven poles and two zeros provided an RMSE of 5.7 and an average RMSE of 17.19 for Healthy cases. The obtained results were provided a generic models of CO with promising outcomes for Paranoid and Healthy cases. Moreover, the BP model has less and yet acceptable results in both Paranoid and Healthy cases.
引用
收藏
页码:1223 / 1240
页数:17
相关论文
共 50 条
[21]   Estimation of cardiac output in a pharmacological trial using a simple method based on arterial blood pressure signal waveform:: a comparison with pulmonary thermodilution and echocardiographic methods [J].
Penttila, Jani ;
Snapir, Amir ;
Kentala, Erkki ;
Koskenvuo, Juha ;
Posti, Jussi ;
Scheinin, Mika ;
Scheinin, Harry ;
Kuusela, Tom .
EUROPEAN JOURNAL OF CLINICAL PHARMACOLOGY, 2006, 62 (06) :401-407
[22]   Reproducing and improving one-dimensional convolutional neural networks for arterial blood pressure-based cardiac output estimation [J].
van Mierlo, Roy R. M. ;
Bouwman, R. Arthur ;
van Riel, Natal A. W. .
2024 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS, MEMEA 2024, 2024,
[23]   Failure Region Estimation of the Linear Voltage Regulator Using Model-Based Approach [J].
Raihan, Muhammad Fauzi Mohd ;
Zamri, Syukri ;
Zaman, Mohd Hairi Mohd ;
Mustafa, M. Marzuki .
2021 INTERNATIONAL CONFERENCE ON DECISION AID SCIENCES AND APPLICATION (DASA), 2021,
[24]   A novel vasopressin peptide lowers blood pressure through decreases in cardiac output [J].
Yu, M ;
Ghosh, M ;
McNeill, JR .
CANADIAN JOURNAL OF PHYSIOLOGY AND PHARMACOLOGY, 2003, 81 (05) :497-501
[25]   Cardiac output in idiopathic normal pressure hydrocephalus: Association with arterial blood pressure and intracranial pressure wave amplitudes and outcome of shunt surgery [J].
Eide P.K. .
Fluids and Barriers of the CNS, 8 (1)
[26]   Camera-Based Blood Pressure Estimation via Windkessel Model and Waveform Features [J].
Wu, Bing-Jhang ;
Wu, Bing-Fei ;
Hsu, Chi-Po .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
[27]   VALIDATION OF A NOVEL METHOD FOR NONINVASIVE ESTIMATION OF CARDIAC OUTPUT USING BRACHIAL OSCILLOMETRIC BLOOD PRESSURE MEASUREMENTS IN PATIENTS WITH VARIOUS CLINICAL CONDITIONS [J].
Madrid-Munoz, Camilo ;
Alvarez-Montoya, Diego ;
Fernandez-Ruiz, Ricardo ;
Gallo-Villegas, Jaime ;
Aristizabal-Ocampo, Dagnovar .
JOURNAL OF HYPERTENSION, 2024, 42 (SUPPL 3)
[28]   Influence of blood pressure and cardiac output on cerebral blood flow and autoregulation in acute stroke measured by TCD [J].
Treib, J ;
Haass, A ;
Koch, D ;
Grauer, MT ;
Stoll, M ;
Schimrigk, K .
EUROPEAN JOURNAL OF NEUROLOGY, 1996, 3 (06) :539-543
[29]   Incorporating pulse wave velocity into model-based pulse contour analysis method for estimation of cardiac stroke volume [J].
Smith, Rachel ;
Balmer, Joel ;
Pretty, Christopher G. ;
Mehta-Wilson, Tashana ;
Desaive, Thomas ;
Shaw, Geoffrey M. ;
Chase, J. Geoffrey .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2020, 195
[30]   Cardiac Output, Blood Pressure Variability, and Cognitive Decline in Geriatric Cardiac Patients [J].
Okonkwo, Ozioma C. ;
Cohen, Ronald A. ;
Gunstad, John ;
Poppas, Athena .
JOURNAL OF CARDIOPULMONARY REHABILITATION AND PREVENTION, 2011, 31 (05) :290-297