Thermal analysis of building roof assisted with water heater and insulation material

被引:0
作者
D Prakash
机构
[1] SASTRA Deemed University,School of Mechanical Engineering
来源
Sādhanā | 2018年 / 43卷
关键词
Thermal analysis; building roof; solar water heating system; roof insulation; numerical simulation;
D O I
暂无
中图分类号
学科分类号
摘要
Traditional roof systems are constructed with concrete and weathering coarse layer and these roof systems absorb and reflect a certain amount of solar radiation. The absorbed solar energy is transferred into building indoor and causes significant discomfort to the occupants. Also, this solar energy gets dissipated without any useful energy conversion. Hence this paper is focused to use the available solar energy effectively through a novel solar water heating system and the transfer of heat in the building indoor is arrested by proper roof insulation material. The modified insulated roof with the solar water heater is designed and simulated numerically in commercial computational fluid dynamics code with validation. Through this study, the factors that affect the performance of solar water heating system and thermal insulation capacity are analysed and the best design of the modified roof system is identified. The modified roof system produces 25 L of hot water per day with a temperature raise of 60°C in the winter season. Also, the same roof system maintains the ceiling temperature at about 27°C for a complete day in a summer season.
引用
收藏
相关论文
共 87 条
  • [1] Suehrcke H(2008)Effect of roof solar reflectance on the building heat gain in a hot climate Energy Build. 40 2224-2235
  • [2] Peterson EL(2006)Performance evaluation of an integrated solar water heater as an option for building energy conservation Energy Build. 38 214-219
  • [3] Selby N(2011)Performance evaluation of evacuated tube solar domestic hot water systems in Hong Kong Energy Build. 43 3467-3474
  • [4] Dharuman C(2012)Building integrated energy storage opportunities in China Renew. Sustain. Energy Rev. 16 6191-6211
  • [5] Arakeri JH(2012)Production efficiency of hot water for domestic use Energy Build. 54 160-168
  • [6] Srinivasan K(2009)Thermal analysis of compact solar water heater under local climatic conditions Int. Commun. Heat Mass Transf. 36 962-968
  • [7] Chow TT(2001)Thermal performance of a solar pressure cooker based on evacuated tube solar collector Appl. Therm. Eng. 21 1699-1706
  • [8] Dong Z(2015)Performance evaluation of all-glass evacuated tube solar water heater with twist tape inserts using CFD Energy Procedia 70 332-339
  • [9] Chan LS(2008)A new design of roof-integrated water solar collector for domestic heating and cooling Solar Energy 82 481-492
  • [10] Fong KF(2014)Experimental and numerical study on phase change material floor in solar water heating system with a new design Solar Energy 105 126-138