A Novel Medical Image Quality Index

被引:0
作者
Sheng-Chieh Lin
You-Chen Lin
Weng-Song Feng
Jia-Ming Wu
Tzong-Jer Chen
机构
[1] Shu-Zen College of Medicine and Management,Department of Dental Laboratory Technology
[2] Central Taiwan University of Science and Technology,Department of Radiological Technology
[3] Shu-Zen College of Medicine and Management,Department of Medical Imaging and Radiology
[4] E-DA Hospital/I-Shou University,Department of Radiation Oncology
来源
Journal of Digital Imaging | 2011年 / 24卷
关键词
Image compression; Image quality analysis; JPEG2000;
D O I
暂无
中图分类号
学科分类号
摘要
A novel medical image quality index using grey relational coefficient calculation is proposed in this study. Three medical modalities, DR, CT and MRI, using 30 or 60 images with a total of 120 images used for experimentation. These images were first compressed at ten different compression ratios (10 ∼ 100) using a medical image compression algorithm named JJ2000. Following that, the quality of the reconstructed images was evaluated using the grey relational coefficient calculation. The results were shown consistent with popular objective quality metrics. The impact of different image aspects on four grey relational coefficient methods were further tested. The results showed that these grey relational coefficients have different slopes but very high consistency for various image areas. Nagai’s grey relational coefficient was chosen in this study because of higher calculation speed and sensitivity. A comparison was also made between this method and other windows-based objective metrics for various window sizes. Studies found that the grey relational coefficient results are less sensitive to window size changes. The performance of this index is better than some windows-based objective metrics and can be used as an image quality index.
引用
收藏
页码:874 / 882
页数:8
相关论文
共 50 条
  • [21] Medical Image on the Go!
    Dragan Ivetic
    Dinu Dragan
    Journal of Medical Systems, 2011, 35 : 499 - 516
  • [22] Novel Algorithms for Secure Medical Image Communication Using Digital Signature with Various Attacks
    Umamageswari, A.
    Suresh, G. R.
    2013 FIFTH INTERNATIONAL CONFERENCE ON ADVANCED COMPUTING (ICOAC), 2013, : 152 - 157
  • [23] Metrics of medical image quality: task-based model observers vs. image discrimination/perceptual difference models
    Eckstein, MP
    Zhang, Y
    Pham, BT
    MEDICAL IMAGING 2004: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2004, 5372 : 42 - 52
  • [24] Quantitative Comparison of Subjective and Objective Medical Image Quality: Applied to Lossy JPEG2000 Compression of Nuclear Medicine Image
    Zhou, Luyi
    Su, Xianyu
    Kuang, Anren
    Li, Lin
    Mo, Tingshu
    PROCEEDINGS OF 2008 INTERNATIONAL PRE-OLYMPIC CONGRESS ON COMPUTER SCIENCE, VOL II: INFORMATION SCIENCE AND ENGINEERING, 2008, : 454 - 457
  • [25] A statistical method for evaluation quality of medical images: a case study in bit discarding and image compression
    Chen, TJ
    Chuang, KS
    Chiang, YC
    Chang, JH
    Liu, RS
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2004, 28 (04) : 167 - 175
  • [26] JPEG2000 Still Image Coding Quality
    Tzong-Jer Chen
    Sheng-Chieh Lin
    You-Chen Lin
    Ren-Gui Cheng
    Li-Hui Lin
    Wei Wu
    Journal of Digital Imaging, 2013, 26 : 866 - 874
  • [27] High-quality image compression for gastrointestinal endoscope
    Dung, Lan-Rong
    Chiang, Tsung-Hsi
    2007 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE, 2007, : 146 - 149
  • [28] Medical image management system
    Varga, Margaret
    Ducksbury, Paul
    Somol, Peter
    INTERNATIONAL JOURNAL OF HEALTHCARE TECHNOLOGY AND MANAGEMENT, 2006, 7 (05) : 387 - 402
  • [29] JPEG2000 Still Image Coding Quality
    Chen, Tzong-Jer
    Lin, Sheng-Chieh
    Lin, You-Chen
    Cheng, Ren-Gui
    Lin, Li-Hui
    Wu, Wei
    JOURNAL OF DIGITAL IMAGING, 2013, 26 (05) : 866 - 874
  • [30] Image quality evaluation
    Bernas, M
    PROCEEDINGS VIPROMCOM-2002, 2002, : 133 - 136