Evaluation of Eustachian tube function by sonotubometry: results and reliability of 8 kHz signals in normal subjects

被引:0
作者
Ercole F. N. Di Martino
Rainer Thaden
Christiane Antweiler
Thorsten Reineke
Martin Westhofen
Jens Beckschebe
Michael Vorländer
Peter Vary
机构
[1] DIAKO Ev. Krankenhaus,ENT Department
[2] Aachen University,Institute of Technical Acoustics
[3] Aachen University,Institute of Communication Systems and Data Processing
[4] University of Applied Sciences,Department of Mathematics and Technology
[5] Aachen University,Department of ENT Diseases and Plastic Head and Neck Surgery
来源
European Archives of Oto-Rhino-Laryngology | 2007年 / 264卷
关键词
Sonotubometry; 8 kHz pure-tone signal; Sensitivity; Reliability;
D O I
暂无
中图分类号
学科分类号
摘要
Sonotubometry allows an assessment of the Eustachian tube (ET) function under physiological conditions. The reliability of the application of an 8 kHz pure-tone signal was investigated. In 40 normal subjects (80 ears) sonotubometric studies were performed with a custom-made device. ET opening was provoked by swallowing, yawning and Valsalva manoeuvre. An opening was detected in all patients but not in all manoeuvres. Four characteristic sonotubogram types were found. Most common was the spike-type (60%). The double-peak and the plateau-shaped curves occured in 17% each. The finding of an descendant curve was rare (5%). Of 623 measurements, only in 55% manouvres a positive sonotubometric result was found despite the fact that the patients reported an opening in all cases. The median opening time in dry swallowing, liquid swallowing, yawning and Valsalva was found to be 486, 355, 1,263 and 1,250 ms. A median sound increase of 16.0, 13.8, 15.0 and 15.0 dB was recorded for these manoeuvres. There was a statistic significant difference (P < 0.02) between the increase in sound intensity of liquid and dry swallowing. There was also a statistic significant difference found for the duration of the forced manoeuvres Valsalva and yawning as compared to dry and liquid swallowing (P < 0.0001). The use of an 8 kHz pure-tone signal showed a limited sensitivity for the detection of ET openings. This is mainly due to noise pollution, but also because of an altered positioning and/or dislocation of the probes and compression of the nostrils. The application of an 8 kHz signal is therefore not reliable enough for the use in practice. Further technical refinements and the use of alternative signals are necessary for a broader clinical application.
引用
收藏
页码:231 / 236
页数:5
相关论文
共 74 条
[1]  
Andreasson L(1984)Eustachian tube function measured as pressure equilibration and sound transmission capacity. A comparison in healthy ears J Otorhinolaryngol Relat Spec 46 74-83
[2]  
Ivarson A(1995)System identification with perfect sequences based on the NLMS Algorithm AEÜ 49 129-134
[3]  
Luttrup S(1981)Panel on experiences with testing Eustachian tube function. Current clinical methods, indications and interpretation of Eustachian tube function tests Ann Otol Rhinol Laryngol 90 552-562
[4]  
Mollerstrom B(2000)Variability of Eustachian tube function comparison of ears with retraction disease and normal ears Laryngoscope 110 1389-1395
[5]  
Tjernstrom O(2004)Eustachian tube function tests current knowledge HNO 52 1029-1040
[6]  
Antweiler C(2004)Einsatz neuer akustischer Signale zur Tubenfunktionsuntersuchung HNO Inf 29 104-1117
[7]  
Antweiler M(2005)Endoscopic examination of the Eustachian Tube A step by step approach Otol Neurootol 26 1112-210
[8]  
Bluestone CD(1980)A new impedance method for measuring middle ear mechanics and Eustachian tube function Ann Otol Rhinol Laryngol Suppl 89 207-434
[9]  
Cantekin EI(1990)The predictive value of Eustachian tube function measured with sonotubometry in the successful outcome of myringoplasty Clin Otolaryngol 15 431-752
[10]  
Bunne M(2000)Kernspintomografische Darstellung und Funktionsdiagnostik der Tuba auditiva Eustachii Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 172 748-1795