Feasibility and correlation of standard 2D speckle tracking echocardiography and automated function imaging derived parameters of left ventricular function during dobutamine stress test

被引:0
|
作者
Karina Wierzbowska-Drabik
Piotr Hamala
Nikolina Roszczyk
Piotr Lipiec
Michał Plewka
Radosław Kręcki
Jarosław Damian Kasprzak
机构
[1] Medical University of Lodz,Chair and Department of Cardiology
来源
The International Journal of Cardiovascular Imaging | 2014年 / 30卷
关键词
Dobutamine stress echocardiography; Speckle tracking; Automated function imaging; Systolic longitudinal strain;
D O I
暂无
中图分类号
学科分类号
摘要
Speckle tracking echocardiography (STE) is a method of quantitative assessment of myocardial function complementary to ejection fraction and visual evaluation. Standard STE analysis, demands manual tracing of the myocardium whereas automated function imaging (AFI) offers more convenient (based on selection of three points) assessment of longitudinal strain. Nevertheless, feasibility and correlation between both methods were not thoroughly examined, especially during tachycardia at peak stage of dobutamine stress echocardiography (DSE). We performed DSE in 238 patients (pts) with recording of apical views during baseline (0) and peak (1) DSE and analyzed them by STE and AFI. According to angiography, 127/238 pts had significant (≥70 %) lesions in coronary arteries. We assessed correlations between STE and AFI derived peak systolic longitudinal strain values for global and regional parameters, feasibility, time of analysis and interobserver agreement. Global systolic longitudinal strain measured during baseline and peak stage of DSE by AFI showed very good correlation with standard STE parameters, with correlation coefficients r = 0.90 and r = 0.86 respectively (p < 0.0001). For regional parameters correlation coefficients ranged from 0.83 to 0.85 for baseline and from 0.70 to 0.79 for peak DSE. Both methods provided good and similar feasibility with only 1 % segments excluded from analysis at peak stage of DSE with shorter time and lower coefficient of variance offered by AFI. Global and regional longitudinal strain achieved by faster and less operator-dependent AFI method correlate well with standard more time-consuming STE analysis during baseline and peak stage of DSE.
引用
收藏
页码:729 / 737
页数:8
相关论文
共 26 条
  • [21] Systolic longitudinal strain correlates with visual assessment of regional left ventricular function during dobutamine stress echocardiography and discriminates the segments with induced contractility impairment
    Wierzbowska-Drabik, Karina
    Miskowiec, Dawid
    Kasprzak, Jaroslaw D.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2017, 34 (07): : 1020 - 1028
  • [22] Definitions for a common standard for 2D speckle tracking echocardiography: consensus document of the EACVI/ASE/Industry Task Force to standardize deformation imaging
    Voigt, Jens-Uwe
    Pedrizzetti, Gianni
    Lysyansky, Peter
    Marwick, Tom H.
    Houle, Helen
    Baumann, Rolf
    Pedri, Stefano
    Ito, Yasuhiro
    Abe, Yasuhiko
    Metz, Stephen
    Song, Joo Hyun
    Hamilton, Jamie
    Sengupta, Partho P.
    Kolias, Theodore J.
    d'Hooge, Jan
    Aurigemma, Gerard P.
    Thomas, James D.
    Badano, Luigi Paolo
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2015, 16 (01) : 1 - 11
  • [23] Definitions for a Common Standard for 2D Speckle Tracking Echocardiography: Consensus Document of the EACVI/ASE/Industry Task Force to Standardize Deformation Imaging
    Voigt, Jens-Uwe
    Pedrizzetti, Gianni
    Lysyansky, Peter
    Marwick, Tom H.
    Houle, Helene
    Baumann, Rolf
    Pedri, Stefano
    Ito, Yasuhiro
    Abe, Yasuhiko
    Metz, Stephen
    Song, Joo Hyun
    Hamilton, Jamie
    Sengupta, Partho P.
    Kolias, Theodore J.
    d'Hooge, Jan
    Aurigemma, Gerard P.
    Thomas, James D.
    Badano, Luigi Paolo
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2015, 28 (02) : 183 - 193
  • [24] Reproducibility of Regional and Global Longitudinal Strains Derived from Two-Dimensional Speckle-Tracking and Doppler Tissue Imaging between Expert and Novice Readers during Quantitative Dobutamine Stress Echocardiography
    Yamada, Akira
    Luis, Sushil A.
    Sathianathan, Daniel
    Khandheria, Bijoy K.
    Cafaro, James
    Hamilton-Craig, Christian R.
    Platts, David G.
    Haseler, Luke
    Burstow, Darryl
    Chan, Jonathan
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2014, 27 (08) : 880 - 887
  • [25] Assessment of left ventricular function by three-dimensional speckle-tracking echocardiography in well-treated type 2 diabetes patients with or without hypertension
    Wang, Qingqing
    Gao, Yunhua
    Tan, Kaibin
    Xia, Hongmei
    Li, Peijing
    JOURNAL OF CLINICAL ULTRASOUND, 2015, 43 (08) : 502 - 511
  • [26] Assessment of left ventricular and atrial diastolic function using two-dimensional (2D) strain imaging in patients with β-thalassemia major
    Karamanou, Alexandra G.
    Hamodraka, Eftihia S.
    Vrakas, Spyridon C.
    Paraskevaidis, Ioannis
    Lekakis, Ioannis
    Kremastinos, Dimitrios Th.
    EUROPEAN JOURNAL OF HAEMATOLOGY, 2014, 92 (01) : 59 - 65