Comparison of longitudinal geometric measurement in human coronary arteries between frequency-domain optical coherence tomography and intravascular ultrasound

被引:0
|
作者
Yong Liu
Kunihiro Shimamura
Takashi Kubo
Atsuhi Tanaka
Hironori Kitabata
Yasushi Ino
Takashi Tanimoto
Yasutsugu Shiono
Makoto Orii
Takashi Yamano
Tomoyuki Yamaguchi
Kumiko Hirata
Toshio Imanishi
Takashi Akasaka
机构
[1] Wakayama Medical University,Department of Cardiovascular Medicine
来源
The International Journal of Cardiovascular Imaging | 2014年 / 30卷
关键词
Optical coherence tomography; Intravascular ultrasound; Coronary angiography; Intracoronary imaging;
D O I
暂无
中图分类号
学科分类号
摘要
Previous studies have demonstrated the higher accuracy of frequency-domain optical coherence tomography (FD-OCT) for quantitative measurements in comparison with intravascular ultrasound (IVUS). However, those analyses were based on the cross-sectional images. The aim of this study was to assess the accuracy of FD-OCT for longitudinal geometric measurements of coronary arteries in comparison with IVUS. Between October 2011 and March 2012, we performed prospective FD-OCT and IVUS examinations in consecutive 77 patients who underwent percutaneous coronary intervention with single stent. Regression analysis and Bland–Altman analysis revealed an excellent correlation between the FD-OCT-measured stent lengths and IVUS-measured stent lengths (r = 0.986, p < 0.001; mean difference = −0.51 mm). There was an excellent agreement between the actual stent lengths and the FD-OCT-measured stent lengths (r = 0.993, p < 0.001) as well as between the actual stent lengths and the IVUS-measured stent lengths (r = 0.981, p < 0.001). The difference between the actual stent lengths and the FD-OCT-measured stent lengths was significantly smaller than that between the actual stent lengths and the IVUS-measured stent lengths (0.15 ± 0.68 vs. 0.70 ± 1.15 mm, p < 0.001). Both FD-OCT (mean difference = −0.04 and −0.04 mm, respectively) and IVUS (mean difference = −0.06 and −0.06 mm, respectively) showed an excellent intra-observer and inter-observer reproducibility for the stent length measurements. In conclusion, FD-OCT provides accurate longitudinal measurement with excellent intra-observer and inter-observer reproducibility. FD-OCT might be a reliable technique for longitudinal geometric measurement in human coronary arteries.
引用
收藏
页码:271 / 277
页数:6
相关论文
共 50 条
  • [41] Comparison of optical coherence tomography-guided and intravascular ultrasound-guided rotational atherectomy for calcified coronary lesions
    Teng, Weili
    Li, Qi
    Ma, Yuliang
    Cao, Chengfu
    Liu, Jian
    Zhao, Hong
    Lu, Mingyu
    Hou, Chang
    Wang, Weimin
    BMC CARDIOVASCULAR DISORDERS, 2021, 21 (01)
  • [42] Assessing the efficacy of saline flush in frequency-domain optical coherence tomography for intracoronary imaging
    Kimura, Masahiro
    Takeda, Teruki
    Tsujino, Yasushi
    Matsumoto, Yuichi
    Yamaji, Masayuki
    Sakaguchi, Tomoko
    Maeda, Keiko
    Mabuchi, Hiroshi
    Murakami, Tomoyuki
    HEART AND VESSELS, 2024, 39 (04) : 310 - 318
  • [43] Assessing the efficacy of saline flush in frequency-domain optical coherence tomography for intracoronary imaging
    Masahiro Kimura
    Teruki Takeda
    Yasushi Tsujino
    Yuichi Matsumoto
    Masayuki Yamaji
    Tomoko Sakaguchi
    Keiko Maeda
    Hiroshi Mabuchi
    Tomoyuki Murakami
    Heart and Vessels, 2024, 39 : 310 - 318
  • [44] Comparison of optical coherence tomography and intravascular ultrasound for evaluation of coronary lipid-rich atherosclerotic plaque progression and regression
    Xie, Zulong
    Tian, Jinwei
    Ma, Lijia
    Du, Hongwei
    Dong, Nana
    Hou, Jingbo
    He, Jieqiong
    Dai, Jiannan
    Liu, Xinxin
    Pan, Hong
    Liu, Youbin
    Yu, Bo
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2015, 16 (12) : 1374 - 1380
  • [45] Comparison of optical coherence tomography-guided and intravascular ultrasound-guided rotational atherectomy for calcified coronary lesions
    Weili Teng
    Qi Li
    Yuliang Ma
    Chengfu Cao
    Jian Liu
    Hong Zhao
    Mingyu Lu
    Chang Hou
    Weimin Wang
    BMC Cardiovascular Disorders, 21
  • [46] Comparative Appraisal of Intravascular Ultrasound and Optical Coherence Tomography in Invasive Coronary Imaging: 2022 Update
    Barus, Piotr
    Modrzewski, Jakub
    Gumiezna, Karolina
    Dunaj, Piotr
    Glod, Marcin
    Bednarek, Adrian
    Wanha, Wojciech
    Roleder, Tomasz
    Kochman, Janusz
    Tomaniak, Mariusz
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (14)
  • [47] Clinical Utility and Significance of Intravascular Ultrasound and Optical Coherence Tomography in Guiding Percutaneous Coronary Interventions
    Hibi, Kiyoshi
    Kimura, Kazuo
    Umemura, Satoshi
    CIRCULATION JOURNAL, 2015, 79 (01) : 24 - 33
  • [48] Dual-modality optical coherence tomography and frequency-domain fluorescence lifetime imaging microscope system for intravascular imaging
    Chen, Xi
    Kim, Wihan
    Serafino, Michael J.
    Tan, Zheng
    Jo, Javier A.
    Applegate, Brian E.
    JOURNAL OF BIOMEDICAL OPTICS, 2020, 25 (09)
  • [49] Relation between baseline plaque features and subsequent coronary artery remodeling determined by optical coherence tomography and intravascular ultrasound
    Xie, Zulong
    Dong, Nana
    Sun, Rong
    Liu, Xinxin
    Gu, Xia
    Sun, Yong
    Du, Hongwei
    Dai, Jiannan
    Liu, Youbin
    Hou, Jingbo
    Tian, Jinwei
    Yu, Bo
    ONCOTARGET, 2017, 8 (03) : 4234 - 4244
  • [50] The Best Strategy for the Black Hole Phenomenon between Intravascular Ultrasound and Optical Coherence Tomography
    Kan, Cheng-Cheng
    Tsai, Wei-Che
    Cheng, Cheng-Chung
    Jong, Gwo-Ping
    DIAGNOSTICS, 2024, 14 (03)