Comparison of longitudinal geometric measurement in human coronary arteries between frequency-domain optical coherence tomography and intravascular ultrasound

被引:0
|
作者
Yong Liu
Kunihiro Shimamura
Takashi Kubo
Atsuhi Tanaka
Hironori Kitabata
Yasushi Ino
Takashi Tanimoto
Yasutsugu Shiono
Makoto Orii
Takashi Yamano
Tomoyuki Yamaguchi
Kumiko Hirata
Toshio Imanishi
Takashi Akasaka
机构
[1] Wakayama Medical University,Department of Cardiovascular Medicine
来源
The International Journal of Cardiovascular Imaging | 2014年 / 30卷
关键词
Optical coherence tomography; Intravascular ultrasound; Coronary angiography; Intracoronary imaging;
D O I
暂无
中图分类号
学科分类号
摘要
Previous studies have demonstrated the higher accuracy of frequency-domain optical coherence tomography (FD-OCT) for quantitative measurements in comparison with intravascular ultrasound (IVUS). However, those analyses were based on the cross-sectional images. The aim of this study was to assess the accuracy of FD-OCT for longitudinal geometric measurements of coronary arteries in comparison with IVUS. Between October 2011 and March 2012, we performed prospective FD-OCT and IVUS examinations in consecutive 77 patients who underwent percutaneous coronary intervention with single stent. Regression analysis and Bland–Altman analysis revealed an excellent correlation between the FD-OCT-measured stent lengths and IVUS-measured stent lengths (r = 0.986, p < 0.001; mean difference = −0.51 mm). There was an excellent agreement between the actual stent lengths and the FD-OCT-measured stent lengths (r = 0.993, p < 0.001) as well as between the actual stent lengths and the IVUS-measured stent lengths (r = 0.981, p < 0.001). The difference between the actual stent lengths and the FD-OCT-measured stent lengths was significantly smaller than that between the actual stent lengths and the IVUS-measured stent lengths (0.15 ± 0.68 vs. 0.70 ± 1.15 mm, p < 0.001). Both FD-OCT (mean difference = −0.04 and −0.04 mm, respectively) and IVUS (mean difference = −0.06 and −0.06 mm, respectively) showed an excellent intra-observer and inter-observer reproducibility for the stent length measurements. In conclusion, FD-OCT provides accurate longitudinal measurement with excellent intra-observer and inter-observer reproducibility. FD-OCT might be a reliable technique for longitudinal geometric measurement in human coronary arteries.
引用
收藏
页码:271 / 277
页数:6
相关论文
共 50 条
  • [31] Morphometric Assessment of Coronary Stenosis Relevance With Optical Coherence Tomography A Comparison With Fractional Flow Reserve and Intravascular Ultrasound
    Gonzalo, Nieve
    Escaned, Javier
    Alfonso, Fernando
    Nolte, Christian
    Rodriguez, Vera
    Jimenez-Quevedo, Pilar
    Banuelos, Camino
    Fernandez-Ortiz, Antonia
    Garcia, Eulogio
    Hernandez-Antolin, Rosana
    Macaya, Carlos
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (12) : 1080 - 1089
  • [32] Safety and efficacy of frequency-domain optical coherence tomography in evaluating and treating intermediate coronary lesions
    Khurwolah, Mohammad Reeaze
    Meng, Hao-Yu
    Wang, Yong-Sheng
    Wang, Lian-Sheng
    Kong, Xiang-Qing
    WORLD JOURNAL OF CARDIOLOGY, 2018, 10 (11): : 222 - 233
  • [33] In Vivo Comparison of Fourier-Domain Optical Coherence Tomography and Intravascular Ultrasonography
    Ramesh, Sathyadeepak
    Papayannis, Aristotelis
    Abdel-karim, Abdul-rahman
    Banerjee, Subhash
    Brilakis, Emmanouil
    JOURNAL OF INVASIVE CARDIOLOGY, 2012, 24 (03) : 111 - 115
  • [34] Clinical Studies of Frequency Domain Optical Coherence Tomography in the Coronary Arteries: The First 2000 Patients
    Petersen, Christopher
    Adler, Desmond
    Schmitt, Joseph
    PHOTONIC THERAPEUTICS AND DIAGNOSTICS VI, 2010, 7548
  • [35] System design and image processing algorithms for frequency domain optical coherence tomography in the coronary arteries
    Adler, Desmond C.
    Xu, Chenyang
    Petersen, Christopher
    Schmitt, Joseph M.
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XIV, 2010, 7554
  • [36] Impact of multiple ballooning on coronary lesions as assessed by optical coherence tomography and intravascular ultrasound
    Kanzaki, Yusuke
    Ueki, Yasushi
    Sunohara, Daisuke
    Okina, Yoshiteru
    Nomi, Hidetomo
    Machida, Keisuke
    Kashiwagi, Daisuke
    Yoda, Hidetsugu
    Maruyama, Shusaku
    Nagae, Ayumu
    Kato, Tamon
    Saigusa, Tatsuya
    Dijkstra, Jouke
    Ebisawa, Soichiro
    Kuwahara, Koichiro
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2024, 104 (05) : 945 - 951
  • [37] Unrestricted utilization of frequency domain optical coherence tomography in coronary interventions
    Stefano, Gregory T.
    Bezerra, Hiram G.
    Mehanna, Emile
    Yamamoto, Hirosada
    Fujino, Yusuke
    Wang, Wei
    Attizzani, Guilherme
    Chamie, Daniel
    Simon, Daniel I.
    Costa, Marco A.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (04) : 741 - 752
  • [38] In vivo coronary lesion differentiation with computed tomography angiography and intravascular ultrasound as compared to optical coherence tomography
    Wieringa, Wouter G.
    Lexis, Chris P. H.
    Lipsic, Erik
    van der Werf, Hindrik W.
    Burgerhof, Johannes G. M.
    Hagens, Vincent E.
    Bartels, G. Louis
    Broersen, Alexander
    Schurer, Remco A.
    Tan, Eng-Shiong
    van der Harst, Pim
    van den Heuvel, Ad F. M.
    Willems, Tineke P.
    Pundziute, Gabija
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2017, 11 (02) : 111 - 118
  • [39] Sex Differences in Nonculprit Coronary Plaque Microstructures on Frequency-Domain Optical Coherence Tomography in Acute Coronary Syndromes and Stable Coronary Artery Disease
    Kataoka, Yu
    Puri, Rishi
    Hammadah, Muhammad
    Duggal, Bhanu
    Uno, Kiyoko
    Kapadia, Samir R.
    Tuzcu, Murat
    Nissen, Steven E.
    King, Peta
    Nicholls, Stephen J.
    CIRCULATION-CARDIOVASCULAR IMAGING, 2016, 9 (08)
  • [40] Optical Coherence Tomography Versus Intravascular Ultrasound to Evaluate Coronary Artery Disease and Percutaneous Coronary Intervention
    Bezerra, Hiram G.
    Attizzani, Guilherme F.
    Sirbu, Vasile
    Musumeci, Giuseppe
    Lortkipanidze, Nikoloz
    Fujino, Yusuke
    Wang, Wei
    Nakamura, Sunao
    Erglis, Andrej
    Guagliumi, Giulio
    Costa, Marco A.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2013, 6 (03) : 228 - 236