Comparison of longitudinal geometric measurement in human coronary arteries between frequency-domain optical coherence tomography and intravascular ultrasound

被引:0
|
作者
Yong Liu
Kunihiro Shimamura
Takashi Kubo
Atsuhi Tanaka
Hironori Kitabata
Yasushi Ino
Takashi Tanimoto
Yasutsugu Shiono
Makoto Orii
Takashi Yamano
Tomoyuki Yamaguchi
Kumiko Hirata
Toshio Imanishi
Takashi Akasaka
机构
[1] Wakayama Medical University,Department of Cardiovascular Medicine
来源
The International Journal of Cardiovascular Imaging | 2014年 / 30卷
关键词
Optical coherence tomography; Intravascular ultrasound; Coronary angiography; Intracoronary imaging;
D O I
暂无
中图分类号
学科分类号
摘要
Previous studies have demonstrated the higher accuracy of frequency-domain optical coherence tomography (FD-OCT) for quantitative measurements in comparison with intravascular ultrasound (IVUS). However, those analyses were based on the cross-sectional images. The aim of this study was to assess the accuracy of FD-OCT for longitudinal geometric measurements of coronary arteries in comparison with IVUS. Between October 2011 and March 2012, we performed prospective FD-OCT and IVUS examinations in consecutive 77 patients who underwent percutaneous coronary intervention with single stent. Regression analysis and Bland–Altman analysis revealed an excellent correlation between the FD-OCT-measured stent lengths and IVUS-measured stent lengths (r = 0.986, p < 0.001; mean difference = −0.51 mm). There was an excellent agreement between the actual stent lengths and the FD-OCT-measured stent lengths (r = 0.993, p < 0.001) as well as between the actual stent lengths and the IVUS-measured stent lengths (r = 0.981, p < 0.001). The difference between the actual stent lengths and the FD-OCT-measured stent lengths was significantly smaller than that between the actual stent lengths and the IVUS-measured stent lengths (0.15 ± 0.68 vs. 0.70 ± 1.15 mm, p < 0.001). Both FD-OCT (mean difference = −0.04 and −0.04 mm, respectively) and IVUS (mean difference = −0.06 and −0.06 mm, respectively) showed an excellent intra-observer and inter-observer reproducibility for the stent length measurements. In conclusion, FD-OCT provides accurate longitudinal measurement with excellent intra-observer and inter-observer reproducibility. FD-OCT might be a reliable technique for longitudinal geometric measurement in human coronary arteries.
引用
收藏
页码:271 / 277
页数:6
相关论文
共 50 条
  • [1] Comparison of longitudinal geometric measurement in human coronary arteries between frequency-domain optical coherence tomography and intravascular ultrasound
    Liu, Yong
    Shimamura, Kunihiro
    Kubo, Takashi
    Tanaka, Atsuhi
    Kitabata, Hironori
    Ino, Yasushi
    Tanimoto, Takashi
    Shiono, Yasutsugu
    Orii, Makoto
    Yamano, Takashi
    Yamaguchi, Tomoyuki
    Hirata, Kumiko
    Imanishi, Toshio
    Akasaka, Takashi
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2014, 30 (02) : 271 - 277
  • [2] Discrepancy between frequency domain optical coherence tomography and intravascular ultrasound in human coronary arteries and in a phantom in vitro coronary model
    Kim, In-Cheol
    Nam, Chang-Wook
    Cho, Yun-Kyeong
    Park, Hyoung-Seob
    Yoon, Hyuck-Jun
    Kim, Hyungseop
    Chung, In-Sung
    Han, Seongwook
    Hur, Seung-Ho
    Kim, Yoon-Nyun
    Kim, Kwon-Bae
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2016, 221 : 860 - 866
  • [3] Impact of Frequency-Domain Optical Coherence Tomography Guidance for Optimal Coronary Stent Implantation in Comparison With Intravascular Ultrasound Guidance
    Habara, Maoto
    Nasu, Kenya
    Terashima, Mitsuyasu
    Kaneda, Hideaki
    Yokota, Daisuke
    Ko, Euihong
    Ito, Tsuyoshi
    Kurita, Tairo
    Tanaka, Nobuyoshi
    Kimura, Masashi
    Ito, Tatsuya
    Kinoshita, Yoshihisa
    Tsuchikane, Etsuo
    Asakura, Keiko
    Asakura, Yasushi
    Katoh, Osamu
    Suzuki, Takahiko
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (02) : 193 - 201
  • [4] Imaging assessment and accuracy in coronary artery autopsy: comparison of frequency-domain optical coherence tomography with intravascular ultrasound and histology
    Aiko Shimokado
    Takashi Kubo
    Yoshiki Matsuo
    Yasushi Ino
    Yasutsugu Shiono
    Kunihiro Shimamura
    Yosuke Katayama
    Akira Taruya
    Tsuyoshi Nishiguchi
    Manabu Kashiwagi
    Hironori Kitabata
    Atsushi Tanaka
    Takeshi Hozumi
    Takashi Akasaka
    The International Journal of Cardiovascular Imaging, 2019, 35 : 1785 - 1790
  • [5] Imaging assessment and accuracy in coronary artery autopsy: comparison of frequency-domain optical coherence tomography with intravascular ultrasound and histology
    Shimokado, Aiko
    Kubo, Takashi
    Matsu, Yoshiki
    Ino, Yasushi
    Shiono, Yasutsugu
    Shimamura, Kunihiro
    Katayama, Yosuke
    Taruya, Akira
    Nishiguchi, Tsuyoshi
    Kashiwagi, Manabu
    Kitabata, Hironori
    Tanaka, Atsushi
    Hozumi, Takeshi
    Akasaka, Takashi
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2019, 35 (10) : 1785 - 1790
  • [6] Frequency-domain optical coherence tomography assessment of unprotected left main coronary artery disease-A comparison with intravascular ultrasound
    Fujino, Yusuke
    Bezerra, Hiram G.
    Attizzani, Guilherme F.
    Wang, Wei
    Yamamoto, Hirosada
    Chamie, Daniel
    Kanaya, Tomoaki
    Mehanna, Emile
    Tahara, Satoko
    Nakamura, Sunao
    Costa, Marco A.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 82 (03) : E173 - E183
  • [7] Quantitative Ex Vivo and In Vivo Comparison of Lumen Dimensions Measured by Optical Coherence Tomography and Intravascular Ultrasound in Human Coronary Arteries
    Gonzalo, Nieves
    Serruys, Patrick W.
    Garcia-Garcia, Hector M.
    van Soest, Gijs
    Okamura, Takayuki
    Ligthart, Jurgen
    Knaapen, Michiel
    Verheye, Stefan
    Bruining, Nico
    Regar, Evelyn
    REVISTA ESPANOLA DE CARDIOLOGIA, 2009, 62 (06): : 615 - 624
  • [8] Volumetric Characterization of Human Coronary Calcification by Frequency-Domain Optical Coherence Tomography
    Mehanna, Emile
    Bezerra, Hiram G.
    Prabhu, David
    Brandt, Eric
    Chamie, Daniel
    Yamamoto, Hirosada
    Attizzani, Guilherme F.
    Tahara, Satoko
    Van Ditzhuijzen, Nienke
    Fujino, Yusuke
    Kanaya, Tomoaki
    Stefano, Gregory
    Wang, Wei
    Gargesha, Madhusudhana
    Wilson, David
    Costa, Marco A.
    CIRCULATION JOURNAL, 2013, 77 (09) : 2334 - 2340
  • [9] Quantitative precision of optical frequency domain imaging: direct comparison with frequency domain optical coherence tomography and intravascular ultrasound
    Kobayashi Y.
    Kitahara H.
    Tanaka S.
    Okada K.
    Kimura T.
    Ikeno F.
    Yock P.G.
    Fitzgerald P.J.
    Honda Y.
    Cardiovascular Intervention and Therapeutics, 2016, 31 (2) : 79 - 88
  • [10] Inter-Scan Reproducibility of Geometric Coronary Artery Measurements Using Frequency-Domain Optical Coherence Tomography
    Orii, Makoto
    Kubo, Takashi
    Tanaka, Atsushi
    Kitabata, Hironori
    Ino, Yasushi
    Shiono, Yasutsugu
    Shimamura, Kunihiro
    Aoki, Hiroshi
    Ohta, Shingo
    Ozaki, Yuichi
    Ishibashi, Kohei
    Yamano, Takashi
    Tanimoto, Takashi
    Yamaguchi, Tomoyuki
    Hirata, Kumiko
    Imanishi, Toshio
    Akasaka, Takashi
    INTERNATIONAL HEART JOURNAL, 2013, 54 (02) : 64 - 67