Accuracy of different navigation systems for femoral and tibial implantation in total knee arthroplasty: a randomised comparative study

被引:0
作者
Yoshitomo Saiki
Tomohiro Ojima
Tamon Kabata
Seigaku Hayashi
Hiroyuki Tsuchiya
机构
[1] Kanazawa University,Department of Orthopaedic Surgery, Graduate School of Medical Sciences
[2] Fukui Health Science University,Department of Rehabilitation Physical Therapy, Faculty of Health Science
[3] Fukui General Hospital,Department of Orthopaedic Surgery
来源
Archives of Orthopaedic and Trauma Surgery | 2021年 / 141卷
关键词
Total knee arthroplasty; Navigation; Accuracy; Outlier; Randomised study;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:2267 / 2276
页数:9
相关论文
共 50 条
  • [21] The accuracy of two different extra-medullary tibial cutting guides for posterior tibial slope in total knee arthroplasty
    Bek, Dogan
    Ege, Tolga
    Yildiz, Cemil
    Tunay, Servet
    Basbozkurt, Mustafa
    EKLEM HASTALIKLARI VE CERRAHISI-JOINT DISEASES AND RELATED SURGERY, 2014, 25 (02): : 75 - 79
  • [22] Comparative Analysis of Diaphyseal versus Metaphyseal tracker Placement in Imageless Navigation Systems for Total Knee Arthroplasty
    Yang, Jae-Hyuk
    Yoon, Jung-Ro
    Lee, Jin Kyu
    JOURNAL OF KNEE SURGERY, 2021, 34 (02) : 216 - 223
  • [23] The accuracy of extramedullary guides for tibial component placement in total knee arthroplasty
    K. Y. Chiu
    W. P. Yau
    T. P. Ng
    W. M. Tang
    International Orthopaedics, 2008, 32 : 467 - 471
  • [24] Accuracy and repeatability of axes for femoral component rotation in total knee arthroplasty: a cadaver study
    Duffy, Siobhan A.
    Goudie, Stuart T.
    Deakin, Angela H.
    Payne, Anthony P.
    Deep, Kamal
    CURRENT ORTHOPAEDIC PRACTICE, 2016, 27 (04): : 427 - 432
  • [25] Unsatisfactory Accuracy as Determined by Computer Navigation of VISIONAIRE Patient-Specific Instrumentation for Total Knee Arthroplasty
    Lustig, Sebastien
    Scholes, Corey J.
    Oussedik, Sam I.
    Kinzel, Vera
    Coolican, Myles R. J.
    Parker, David A.
    JOURNAL OF ARTHROPLASTY, 2013, 28 (03) : 469 - 473
  • [26] Accuracy of Computed Tomography-Based Navigation-Assisted Total Knee Arthroplasty: Outlier Analysis
    Miyasaka, Teruyuki
    Kurosaka, Daisaburo
    Saito, Mitsuru
    Omori, Toshiyuki
    Ikeda, Ryo
    Marumo, Keishi
    JOURNAL OF ARTHROPLASTY, 2017, 32 (01) : 47 - 52
  • [27] Accuracy of tibial positioning in the frontal plane: a prospective study comparing conventional and innovative techniques in total knee arthroplasty
    Zahn, R. K.
    Graef, F.
    Conrad, J. L.
    Renner, L.
    Perka, C.
    Hommel, H.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2020, 140 (06) : 793 - 800
  • [28] Isolated Femoral or Tibial Component Revision in Total Knee Arthroplasty:A Systematic Review
    Maestri, Marco
    Castagnini, Francesco
    Giardina, Federico
    Tella, Giuseppe
    Tassinari, Enrico
    Traina, Francesco
    MEDICAL PRINCIPLES AND PRACTICE, 2023, 32 (4-5) : 225 - 231
  • [29] Accuracy of the Precision Saw versus the Sagittal Saw during total knee arthroplasty: A randomised clinical trial
    Feczko, Peter Z.
    Fokkenrood, Hugo J. P.
    van Assen, Tijmen
    Deckers, Patrick
    Emans, Pieter J.
    Arts, Jacobus J.
    KNEE, 2017, 24 (05) : 1213 - 1220
  • [30] Accuracy of tibial positioning in the frontal plane: a prospective study comparing conventional and innovative techniques in total knee arthroplasty
    R. K. Zahn
    F. Graef
    J. L. Conrad
    L. Renner
    C. Perka
    H. Hommel
    Archives of Orthopaedic and Trauma Surgery, 2020, 140 : 793 - 800