Thermoluminescence dosimetry for in-vivo verification of high dose rate brachytherapy for prostate cancer

被引:0
作者
R. Das
W. Toye
T. Kron
S. Williams
G. Duchesne
机构
[1] RMIT University,Department of Applied Physics
[2] Radiation Oncology Victoria,School of Medicine and Health Sciences
[3] University of Melbourne,Department of Physical Sciences
[4] Peter MacCallum Cancer Centre,undefined
来源
Australasian Physics & Engineering Sciences in Medicine | 2007年 / 30卷
关键词
HDR brachytherapy; prostate cancer; in-vivo dosimetry; TLD; treatment planning; rectum dose; urethra dose;
D O I
暂无
中图分类号
学科分类号
摘要
It was the aim of the study to verify dose delivered in urethra and rectum during High Dose Rate brachytherapy boost (HDRBB) of prostate cancer patients. During the first fraction of HDRBB measurement catheters were placed in the urethra and rectum of prostate cancer patients. These contained LiF:Mg,Ti Thermoluminescence Dosimetry (TLD) rods of 1mm diameter, with up to 11 detectors positioned every 16 mm separated by radio-opaque markers. A Lorentzian peak function was used to fit the data. Measurements from 50 patients were evaluated and measured doses were compared with predictions from the treatment planning system (Plato Vs 13.5 to 14.1). Prospective urinary and rectal toxicity scores were collected following treatment. In more than 90% of cases, the Lorentzian peak function provided a good fit to both experimental and planning urethral data (r2 > 0.9). In general there was good agreement between measured and predicted doses with the average difference between measured and planned maximum dose being 0.1Gy. No significant association between dose and any clinical endpoints was observed in 43 patients available for clinical evaluation. An average inferior shift of 2 mm between the plan and the measurement performed approximately 1 hour after the planning CT scan was found for the dose distribution in the cohort of patients for the urethra measurements. Rectal measurements proved to be more difficult to interpret as there is more variability of TLD position between planning and treatment. TLD in-vivo measurements are easily performed in urethra and rectum during HDR brachytherapy of prostate patients. They verify the delivery and provide information about the dose delivered to critical structures. The latter may be of particular interest if higher doses are to be given per fraction such as in HDR monotherapy.
引用
收藏
页码:178 / 184
页数:6
相关论文
共 50 条
  • [31] Dosimetry procedure to verify dose in High Dose Rate (HDR) brachytherapy treatment of cancer patients: A systematic review
    Jayakody, Mahesha
    Jeyasugiththan, Jeyasingam
    Rajasooriyar, Chrishanthi
    Chougule, Arun
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 96 : 70 - 80
  • [32] Interfractional fluctuation of rectal dose in high dose rate brachytherapy for prostate cancer
    Ishikawa H.
    Sato M.
    Shirai S.
    Kishi K.
    Naya Y.
    Tokunaga H.
    Radiation Medicine, 2006, 24 (9): : 610 - 616
  • [33] High-dose-rate brachytherapy boost for prostate cancer: Outcomes and genitourinary toxicity
    Bece, Andrej
    Patanjali, Nitya
    Jackson, Michael
    Whitaker, May
    Hruby, George
    BRACHYTHERAPY, 2015, 14 (05) : 670 - 676
  • [34] Salvage high-dose-rate brachytherapy for recurrent prostate cancer
    Kaprin, A. D.
    Ivanov, S. A.
    Karyakin, O. B.
    Obuhov, A. A.
    Biryukov, V. A.
    Borysheva, N. B.
    Sanin, D. B.
    Lepilina, O. G.
    Smolkin, A. L.
    Dem'yanovich, A., V
    Minaeva, N. G.
    Mikhaylovskiy, N., V
    ONKOUROLOGIYA, 2020, 16 (04): : 112 - 119
  • [35] High-dose-rate brachytherapy as monotherapy for prostate cancer: technique, rationale and perspective
    Yoshioka, Yasuo
    Suzuki, Osamu
    Otani, Yuki
    Yoshida, Ken
    Nose, Takayuki
    Ogawa, Kazuhiko
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2014, 6 (01) : 91 - 98
  • [36] Monotherapeutic high-dose-rate brachytherapy for prostate cancer: A dose reduction trial
    Yoshioka, Yasuo
    Konishi, Koji
    Suzuki, Osamu
    Nakai, Yasutomo
    Isohashi, Fumiaki
    Seo, Yuji
    Otani, Yuki
    Koizumi, Masahiko
    Yoshida, Ken
    Yamazaki, Hideya
    Nonomura, Norio
    Ogawa, Kazuhiko
    RADIOTHERAPY AND ONCOLOGY, 2014, 110 (01) : 114 - 119
  • [37] Applicability of Glass Dosimeters for In-vivo Dosimetry in Brachytherapy
    Sun Young Moon
    Jaeman Son
    Myonggeun Yoon
    EunHee Jeang
    Young Kyung Lim
    Weon Kyu Chung
    Dong Wook Kim
    Journal of the Korean Physical Society, 2018, 72 : 1320 - 1325
  • [38] Online in vivo dosimetry in high dose rate prostate brchytherapy with MOSkin detectors: In phantom feasibility study
    Gambarini, G.
    Carrara, M.
    Tenconi, C.
    Mantaut, N.
    Borroni, M.
    Cutajar, D.
    Petasecca, M.
    Fuduli, I.
    Lerch, M.
    Pignoli, E.
    Rosenfeld, A.
    APPLIED RADIATION AND ISOTOPES, 2014, 83 : 222 - 226
  • [39] 3D dose reconstruction based on in vivo dosimetry for determining the dosimetric impact of geometric variations in high-dose-rate prostate brachytherapy
    Jorgensen, Erik B.
    Buus, Simon
    Bentzen, Lise
    Hokland, Steffen B.
    Rylander, Susanne
    Kertzscher, Gustavo
    Beddar, Sam
    Tanderup, Kari
    Johansen, Jacob G.
    RADIOTHERAPY AND ONCOLOGY, 2022, 171 : 62 - 68
  • [40] American Brachytherapy Society consensus guidelines for high-dose-rate prostate brachytherapy
    Yamada, Yoshiya
    Rogers, Leland
    Demanes, D. Jeffrey
    Morton, Gerard
    Prestidges, Bradley R.
    Pouliot, Jean
    Cohen, Gil'ad N.
    Zaider, Marco
    Ghilezan, Mihai
    Hsu, I-Chow
    BRACHYTHERAPY, 2012, 11 (01) : 20 - 32