Energetic and exergetic performance comparison of cascade refrigeration system using R170-R161 and R41-R404A as refrigerant pairs

被引:0
作者
Ranendra Roy
Bijan Kumar Mandal
机构
[1] Indian Institute of Engineering Science and Technology,Department of Mechanical Engineering
[2] Shibpur,undefined
来源
Heat and Mass Transfer | 2019年 / 55卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
A numerical study of cascade refrigeration system using two different refrigerant pairs, namely, R41–R404A and R170–R161 working under the same operating conditions has been presented in this paper. A computer code has been developed in Engineering Equation Solver software using the basic energy and exergy equations of cascade refrigeration system. Values of some of the important input parameters for the analysis have been taken from the literatures to carry out this simulation work. The effect of evaporator temperature on the basic performance parameters, such as COP, compressor power, total exergy destruction, exergetic efficiency has been computed. The analysis of the predicted results shows that for each evaporator temperature, an optimal point exists where the system shows maximum performance. An effective reduction of compressor work and total exergy loss is observed with R170–R161 system than those of the R41–R404A system. This eventually results in higher optimal COP as well as exergetic efficiency for R170–R161 system compared to R41–R404A system.
引用
收藏
页码:723 / 731
页数:8
相关论文
共 50 条
[41]   The thermodynamic and environmental analysis of a variable speed R404A refrigeration system using R455A [J].
Devecioglu, Atilla G. ;
Oruc, Vedat .
THERMAL SCIENCE AND ENGINEERING PROGRESS, 2024, 56
[42]   Operation performance of an ultralow-temperature cascade refrigeration freezer with environmentally friendly refrigerants R290-R170 [J].
Tan, Haihui ;
Xu, Lingfei ;
Yang, Linlin ;
Bai, Minkai ;
Liu, Zhan .
ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2023, 30 (11) :29790-29806
[43]   Operation performance of an ultralow-temperature cascade refrigeration freezer with environmentally friendly refrigerants R290-R170 [J].
Haihui Tan ;
Lingfei Xu ;
Linlin Yang ;
Minkai Bai ;
Zhan Liu .
Environmental Science and Pollution Research, 2023, 30 :29790-29806
[44]   Prototype of hybrid refrigeration system using refrigerant R723 [J].
Lychnos, G. ;
Tamainot-Telto, Z. .
APPLIED THERMAL ENGINEERING, 2018, 134 :95-106
[45]   EVALUATION OF THE PERFORMANCE OF USING R410A AND R463A IN A VAPOR COMPRESSION REFRIGERATION SYSTEM: ENERGETIC-EXERGETIC ANALYSIS AND ENVIRONMENTAL IMPACT INDEX (EII) ASSESSMENT [J].
Yildirim, Ragip ;
Kumas, Kazim ;
Akyuz, Ali ;
Tuncer, Azim Dogus .
HEAT TRANSFER RESEARCH, 2025, 56 (03) :1-13
[46]   Comparison of air-source heat pump water heater performance with transcritical cycle using CO2, R170 and R41 as refrigerant [J].
Wang D. ;
Liu Y. ;
Chen Z. ;
Kou Z. ;
Lu Y. .
Huagong Xuebao/CIESC Journal, 2020, 71 :51-56
[47]   Practical comparison of performance between CO2 (R744)/R404A cascade and direct expansion R404A systems in freezer applications [J].
Japp, Andrew ;
Wilson, Ian .
PROCEEDINGS OF THE 3RD ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING VOLS I AND II, 2006, :479-+
[48]   Performance study on a vapour compression refrigeration cycle using R744/R290, R744/R600 or R744/R600a as refrigerant [J].
Zhang, Xianping ;
Qin, Guimian ;
Wang, Fengkun ;
Fan, Xiaowei ;
Shen, Henggen .
FIRST INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT, PROCEEDINGS VOLS 1-3, 2008, :1609-1615
[50]   Thermodynamic Comparative Analysis of Cascade Refrigeration System Pairing R744 with R404A, R448A, and R449A with Internal Heat Exchanger: Part 1-Coefficient of Performance Characteristics [J].
Jeon, Min-Ju ;
Lee, Joon-Hyuk .
ENERGIES, 2024, 17 (17)