Bioaerosol levels and the indoor air quality of laboratories in Bangkok metropolis

被引:0
|
作者
Kraiwuth Kallawicha
H. Jasmine Chao
Natkrita Kotchasatan
机构
[1] Chulabhorn Royal Academy,Environmental Toxicology Program, Chulabhorn Graduate Institute
[2] Center of Excellence on Environmental Health and Toxicology (EHT),School of Public Health
[3] Office of Higher Education Commission,undefined
[4] Ministry of Education,undefined
[5] Taipei Medical University,undefined
来源
Aerobiologia | 2019年 / 35卷
关键词
Bioaerosols; Indoor air quality; Laboratory; Fungi; Bacteria; Fungal spore;
D O I
暂无
中图分类号
学科分类号
摘要
Bioaerosols are major air pollutants commonly found both indoors and outdoors. High exposure levels may result in various adverse health outcomes. Laboratories, which are indoor environments carefully designed for specific purposes, may contain high levels of bioaerosols, which may threaten worker’s health, and contaminate experimental results. This study investigated the levels of bioaerosols (i.e., culturable fungi and bacteria, and fungal spores) in laboratories in the Bangkok metropolitan area. Air samples were collected from 14 Class I and one Class II laboratories by using a single-stage impactor and a VersaTrap spore trap cassette. Colonies were counted after 72 h and 48 h of incubation for culturable fungi and bacteria, respectively. Culturable fungi and fungal spores were identified based on their morphological characteristics. Associations between bioaerosols and indoor air parameters and laboratory characteristics were evaluated. The concentrations (mean ± SD) of culturable bacteria, culturable fungi, and fungal spores were 87.0 ± 97.8 CFU/m3, 294.9 ± 376.1 CFU/m3, and 771.8 ± 545.3 spores/m3, respectively. Aspergillus/Penicillium, ascospores, and Cladosporium were common fungal spore taxa in the laboratories. Culturable fungi significantly increased with the number of staff and visible molds, whereas water leaks and culturable fungi significantly increased fungal spore concentrations. Culturable bacteria were positively associated with the numbers of trash bins and − 80 °C freezers. Although bioaerosol concentrations were considerably lower in the studied laboratories, proper indoor air management is still suggested in order to reduce emissions and exposure. This can help workers avoid adverse health outcomes and reduce the chance of experimental contamination.
引用
收藏
页码:1 / 14
页数:13
相关论文
共 50 条
  • [1] Bioaerosol levels and the indoor air quality of laboratories in Bangkok metropolis
    Kallawicha, Kraiwuth
    Chao, H. Jasmine
    Kotchasatan, Natkrita
    AEROBIOLOGIA, 2019, 35 (01) : 1 - 14
  • [2] Ambient bioaerosol indices for indoor air quality assessments of flood reclamation
    Fabian, MP
    Miller, SL
    Reponen, T
    Hernandez, MT
    JOURNAL OF AEROSOL SCIENCE, 2005, 36 (5-6) : 763 - 783
  • [3] Indoor air quality - bioaerosol measurements in domestic and office premises
    Kalogerakis, N
    Paschali, D
    Lekaditis, V
    Pantidou, A
    Eleftheriadis, K
    Lazaridis, M
    JOURNAL OF AEROSOL SCIENCE, 2005, 36 (5-6) : 751 - 761
  • [4] Artificial intelligence-based prediction of indoor bioaerosol concentrations from indoor air quality sensor data
    Lee, Justin Y. Y.
    Miao, Yanhao
    Chau, Ricky L. T.
    Hernandez, Mark
    Lee, Patrick K. H.
    ENVIRONMENT INTERNATIONAL, 2023, 174
  • [5] Attempt to improve indoor air quality in computer laboratories
    Telejko, Marek
    MODERN BUILDING MATERIALS, STRUCTURES AND TECHNIQUES, 2017, 172 : 1154 - 1160
  • [6] Indoor and outdoor bioaerosol levels at recreation facilities, elementary schools, and homes
    Jo, WK
    Seo, YJ
    CHEMOSPHERE, 2005, 61 (11) : 1570 - 1579
  • [7] Monitoring viable fungal and bacterial bioaerosol concentrations to identify acceptable levels for common indoor environments
    Robertson, LD
    INDOOR AND BUILT ENVIRONMENT, 1997, 6 (05) : 295 - 300
  • [8] Physical parameters influence the microbial quality of indoor air in research laboratories: A report from Malaysia
    Yogeswaran, Kuilan
    Azmi, Liyana
    Bhassu, Subha
    Isa, Hafizah N.
    Aziz, Muhamad Afiq
    KUWAIT JOURNAL OF SCIENCE, 2023, 50 (04) : 665 - 673
  • [9] LABORATORY FACILITY DESIGN AND MICROBIAL INDOOR AIR QUALITY IN SELECTED HOSPITAL LABORATORIES
    Luksamijarulkul, Pipat
    Kiennukul, Nuchanard
    Vatthanasomboon, Pisit
    SOUTHEAST ASIAN JOURNAL OF TROPICAL MEDICINE AND PUBLIC HEALTH, 2014, 45 (03) : 746 - 755
  • [10] A field study of indoor air quality and occupant perception in experimental laboratories and workshops
    Kwong, Qi Jie
    Abdullah, Jamalunlaili
    Tan, Sheng Chuan
    Thio, Tzer Hwai Gilbert
    Yeaw, Win Shyang
    MANAGEMENT OF ENVIRONMENTAL QUALITY, 2019, 30 (02) : 467 - 482