Comparison of photon organ and effective dose coefficients for PIMAL stylized phantom in bent positions in standard irradiation geometries

被引:0
作者
Shaheen Dewji
K. Lisa Reed
Mauritius Hiller
机构
[1] Oak Ridge National Laboratory,Center for Radiation Protection Knowledge, Environmental Sciences Division
[2] Georgia Institute of Technology,Nuclear and Radiological Engineering Program
来源
Radiation and Environmental Biophysics | 2017年 / 56卷
关键词
Anthropomorphic phantoms; Monte Carlo simulation; MCNP; Dose reconstruction;
D O I
暂无
中图分类号
学科分类号
摘要
Computational phantoms with articulated arms and legs have been constructed to enable the estimation of radiation dose in different postures. Through a graphical user interface, the Phantom wIth Moving Arms and Legs (PIMAL) version 4.1.0 software can be employed to articulate the posture of a phantom and generate a corresponding input deck for the Monte Carlo N-Particle (MCNP) radiation transport code. In this work, photon fluence-to-dose coefficients were computed using PIMAL to compare organ and effective doses for a stylized phantom in the standard upright position with those for phantoms in realistic work postures. The articulated phantoms represent working positions including fully and half bent torsos with extended arms for both the male and female reference adults. Dose coefficients are compared for both the upright and bent positions across monoenergetic photon energies: 0.05, 0.1, 0.5, 1.0, and 5.0 MeV. Additionally, the organ doses are compared across the International Commission on Radiological Protection’s standard external radiation exposure geometries: antero-posterior, postero-anterior, left and right lateral, and isotropic (AP, PA, LLAT, RLAT, and ISO). For the AP and PA irradiation geometries, differences in organ doses compared to the upright phantom become more profound with increasing bending angles and have doses largely overestimated for all organs except the brain in AP and bladder in PA. In LLAT and RLAT irradiation geometries, energy deposition for organs is more likely to be underestimated compared to the upright phantom, with no overall change despite increased bending angle. The ISO source geometry did not cause a significant difference in absorbed organ dose between the different phantoms, regardless of position. Organ and effective fluence-to-dose coefficients are tabulated. In the AP geometry, the effective dose at the 45° bent position is overestimated compared to the upright phantom below 1 MeV by as much as 27% and 82% in the 90° position. The effective dose in the 45° bent position was comparable to that in the 90° bent position for the LLAT and RLAT irradiation geometries. However, the upright phantom underestimates the effective dose to PIMAL in the LLAT and RLAT geometries by as much as 30% at 50 keV.
引用
收藏
页码:277 / 291
页数:14
相关论文
共 56 条
  • [1] Akkurt H(2007)PIMAL: phantom with moving arms and legs Trans Am Nucl Soc 96 396-397
  • [2] Eckerman KF(2014)Organ and effective dose conversion coefficients for a sitting female hybrid computational phantom exposed to monoenergetic protons in idealized irradiation geometries Phys Med Biol 59 7957-286
  • [3] Wagner JC(2010)Dose conversion coefficients for photon exposure of the human eye lens Phys Med Biol 56 415-111
  • [4] Sherbini S(2017)Effective dose rate coefficients for immersions in radioactive air and water Radiat Prot Dosim 174 275-160
  • [5] Alves M(2015)Dosimetric models of the eye and lens of the eye and their use in assessing dose coefficients for ocular exposures Ann ICRP 44 91-235
  • [6] Santos W(2014)Comparison of conversion coefficients for equivalent dose in terms of air kerma using a sitting and standing female adult voxel simulators exposure to photons in antero-posterior irradiation geometry Radiat Phys Chem 95 158-60
  • [7] Lee C(2014)Comparison of conversion coefficients for equivalent dose in terms of air kerma for photons using a male adult voxel simulator in sitting and standing posture with geometry of irradiation antero-posterior Radiat Phys Chem 95 233-356
  • [8] Bolch WE(2016)Fluence-to-dose conversion coefficients based on the posture modification of adult male (AM) and adult female (AF) reference phantoms of ICRP 110 Radiat Phys Chem 121 50-45
  • [9] Hunt JG(2006)Revisions to the ORNL series of adult and pediatric computational phantoms for use with the MIRD schema Health Phys 90 337-395
  • [10] Júnior AC(2014)Effective dose conversion coefficients for health care provider exposed to pediatric and adult victims in radiological dispersal device incident J Radiol Prot 35 37-443