Design method for fluid viscous dampers

被引:0
作者
Jia Jiuhong
Du Jianye
Wang yu
Hua Hongxing
机构
[1] Shanghai Jiaotong University,State Key Laboratory of Mechanical System and Vibration
[2] Naval Arming Academy,Institute of Naval Vessels
来源
Archive of Applied Mechanics | 2008年 / 78卷
关键词
Fluid viscous dampers; Piping system; Damping coefficient; Nonlinear viscous damping;
D O I
暂无
中图分类号
学科分类号
摘要
A basic design method of doubly acting fluid viscous dampers with double guide bars is presented. The flow of the viscoelastic fluid between two parallel plates, one of which is started suddenly and the other of which is still, is analyzed. According to this solution, the velocity and the shear stress of the fluid at the fringe of the piston are solved approximately. A mathematical model of viscous dampers is derived, and the shock test is carried out. From experimental results, the parameters of the mathematical model are determined. Consequently, a semi-empirical design equation is obtained. Applying this equation to a certain practical damper, the damping material is chosen and the physical dimensions of the damper are determined. Shock tests using this damper are performed. Theoretical results are in good agreement with experimental results, which validates the reliability of the calculated physical dimensions of the specimen damper and the validity of the basic design equation.
引用
收藏
页码:737 / 746
页数:9
相关论文
共 27 条
[1]  
Pekcan G.(1995)The seismic response of a 1:3 scale model R.C. structure with elastomeric spring dampers Earthq. Spectra 11 249-267
[2]  
Mander J.B.(2002)Passive damping devices for aerospace structures Acta Astronaut. 50 597-608
[3]  
Chen S.S.(2003)Lyapunov design of damping controllers Arch. Appl. Mech. 72 865-874
[4]  
Rittweger A.(1997)Structural control: past, present and future J. Eng. Mech. 123 897-909
[5]  
Albus J.(2003)An optimum retrofit strategy for moment resisting frames with nonlinear viscous dampers for seismic applications Eng. Struct. 25 913-925
[6]  
Hornung E.(2005)Seismic response of linear and non-linear asymmetric systems with non-linear fluid viscous dampers Earthq. Eng. Struct. Dyn. 34 825-846
[7]  
Nitsche R.(1993)Experimental study of seismic response of buildings with supplemental fluid dampers linebreak J. Struct. Eng. 2 93-132
[8]  
Gaul L.(1995)Usteady axial viacoelastic pipe flows J. Non-Newton. Fluid Mech. 57 27-38
[9]  
Housner G.W.(2000)Resonance behavior of viscoelastic fluids in Poiseuille flow and application to flow enhancement Int. J. Non-Lin. Mech. 35 9-102
[10]  
Bergman L.A.(2003)Fetecaub Corina: A new exact solution for the flow of a Maxwell fluid past an infinite plate Int. J. Non-Linear Mech. 38 423-427