Use of the Tubridge flow diverter in the treatment of intracranial aneurysms: a single center experience

被引:3
作者
Li, Li [1 ]
Gao, Bu-Lang [1 ]
Wu, Qiao-Wei [1 ]
Shao, Qiu-Ji [1 ]
Wang, Zi-Liang [1 ]
Zhang, Kun [1 ]
Li, Tian-Xiao [1 ]
机构
[1] Zhengzhou Univ, Henan Prov Peoples Hosp, 7 Weiwu Rd, Zhengzhou, Henan, Peoples R China
关键词
Intracranial aneurysms; Tubridge flow diverter; Endovascular embolization; Complications; Follow-up; PIPELINE EMBOLIZATION DEVICE; STENT-ASSISTED COILING; ARTERY ANEURYSM; MULTICENTER; METAANALYSIS;
D O I
10.1038/s41598-024-57840-2
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
To investigate the safety and effect of Tubridge flow diverter deployment for the treatment of intracranial aneurysms, 85 patients with intracranial aneurysms treated with the Tubridge flow diverter were retrospectively enrolled. The clinical data including the baseline data, aneurysm parameters before and after treatment, and follow-up outcomes were assessed. Among 85 patients, there were 35 (41.2%) males and 50 females (58.8%) aged 17-77 (mean 56.7 +/- 11.1) years with 110 aneurysms. Five (5.9%) patients initially presented with subarachnoid hemorrhage from aneurysm rupture. The aneurysm size was 2-30 (mean 8.6) mm, and the aneurysm neck was 2-10.6 (mean 5.7 +/- 2.3) mm. Ninety-three Tubridge stents were deployed. Twenty-five (29.4%) patients experienced adjunctive loose coiling. Blood flow was significantly reduced from entering the aneurysm after stent deployment. Periprocedural complications occurred in three (3.5%) patients, including in-stent thrombosis during embolization in one patient (1.2%), conjunctiva edema on the right in one patient (1.2%), and acute multiple cerebral infarctions in one patient (1.2%). Angiographic follow-up was conducted in 67 (78.8%) patients 3-36 (mean 15.3 +/- 5.6) months later. In 11 (16.4% or 11/67) patients, blood flow still entered the aneurysm with the O'Kelly-Marotta (OKM) grade B in two (3.0%) patients and grade C in nine (13.4%), whereas complete occlusion (OKM grade D) was achieved in the other 56 (83.6% or 56/67) aneurysms. In-stent stenosis was present in five (7.5%) patients with approximately 25% stenosis in three (4.5%) patients and 50% in two (3.0%). In conclusion, the Tubridge flow diverter can be safely and efficiently applied in the treatment of small and large intracranial aneurysms, with a low periprocedural complication rate, a high occlusion degree, and a low in-stent stenosis rate at follow-up even though large aneurysms may necessitate a longer surgical time and adjunctive coiling.
引用
收藏
页数:10
相关论文
共 37 条
[1]   Pipeline for uncoilable or failed aneurysms: 3-year follow-up results [J].
Becske, Tibor ;
Potts, Matthew B. ;
Shapiro, Maksim ;
Kallmes, David F. ;
Brinjikji, Waleed ;
Saatci, Isil ;
McDougall, Cameron G. ;
Szikora, Istvan ;
Lanzino, Giuseppe ;
Moran, Christopher J. ;
Woo, Henry H. ;
Lopes, Demetrius K. ;
Berez, Aaron L. ;
Cher, Daniel J. ;
Siddiqui, Adnan H. ;
Levy, Elad I. ;
Albuquerque, Felipe C. ;
Fiorella, David J. ;
Berentei, Zsolt ;
Marosfoi, Miklos ;
Cekirge, Saruhan H. ;
Nelson, Peter K. .
JOURNAL OF NEUROSURGERY, 2017, 127 (01) :81-88
[2]   Safety and efficacy of Surpass Evolve Flow diverter for intracranial aneurysms: A study of 116 patients [J].
Bibi, Richard ;
Bankole, Nourou Dine Adeniran ;
Donnard, Baptiste ;
Giubbolini, Francesca ;
Boucherit, Julien ;
Barrot, Valere ;
Herbreteau, Denis ;
Ifergan, Heloise ;
Janot, Kevin ;
Boulouis, Gregoire ;
Bala, Fouzi .
NEURORADIOLOGY JOURNAL, 2024, 37 (02) :184-191
[3]   Diversion-p64: results from an international, prospective, multicenter, single-arm post-market study to assess the safety and effectiveness of the p64 flow modulation device [J].
Bonafe, Alain ;
Perez, Marta Aguilar ;
Henkes, Hans ;
Lylyk, Pedro ;
Bleise, Carlos ;
Gascou, Gregory ;
Sirakov, Stanimir ;
Sirakov, Alexander ;
Stockx, Luc ;
Turjman, Francis ;
Petrov, Andrey ;
Roth, Christian ;
Narata, Ana-Paula ;
Barreau, Xavier ;
Loehr, Christian ;
Berlis, Ansgar ;
Pierot, Laurent ;
Mis, Marcin ;
Goddard, Tony ;
Clifton, Andy ;
Klisch, Joachim ;
Walesa, Cezary ;
Dall'Olio, Massimo ;
Spelle, Laurent ;
Clarencon, Frederic ;
Yakovlev, Sergey ;
Keston, Peter ;
Nuzzi, Nunzio Paolo ;
Dima, Stefanita ;
Wendl, Christina ;
Willems, Tine ;
Schramm, Peter .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2021, :898-903
[4]   A multicenter retrospective controlled study of the Pipeline and Tubridge Flow Diverter devices for intracranial wide-necked aneurysms [J].
Cai, Heng ;
Yang, Fangyu ;
Xu, Yousong ;
Geng, Yu ;
Li, Jinwei ;
Li, Yugang ;
Fu, Kailei ;
Liu, Chang ;
Wang, Meiyan ;
Li, Zhiqing .
FRONTIERS IN NEUROLOGY, 2022, 13
[5]   Flow Diverter Devices for Treatment of Intracranial Aneurysms in Small Parent Vessels-A Systematic Review of Literature [J].
Dabhi, Nisha ;
Sarathy, Danyas ;
Snyder, M. Harrison ;
Kellogg, Ryan T. ;
Park, Min S. .
WORLD NEUROSURGERY, 2022, 162 :183-+
[6]   Treatment of Traumatic Internal Carotid Artery Aneurysm by Flow-Diverter: A Single-Center Experience [J].
Dogan, Adem ;
Durmaz, Mehmet Ozan ;
Yuce, Gokhan ;
Ezgu, Mehmet Can .
NEUROCHIRURGIE, 2022, 68 (06) :E60-E67
[7]   Silk® Flow Diverter Device for Intracranial Aneurysm Treatment: A Systematic Review and Meta-Analysis [J].
Florez, William A. ;
Garcia-Ballestas, Ezequiel ;
Quinones-Ossa, Gabriel Alexander ;
Janjua, Tariq ;
Konar, Subhas ;
Agrawal, Amit ;
Moscote-Salazar, Luis Rafael .
NEUROINTERVENTION, 2021, 16 (03) :222-231
[8]   Long-term Follow-up Results after Flow Diverter Therapy Using the Pipeline Embolization Device for Large or Giant Unruptured Internal Carotid Artery Aneurysms: Single-center Retrospective Analysis in the Japanese Population [J].
Fujii, Takashi ;
Teranishi, Kohsuke ;
Yatomi, Kenji ;
Suzuki, Kazumoto ;
Mitome-Mishima, Yumiko ;
Kondo, Akihide ;
Oishi, Hidenori .
NEUROLOGIA MEDICO-CHIRURGICA, 2022, 62 (01) :19-27
[9]   Hemodynamic Characteristics and Clinical Outcome for Intracranial Aneurysms Treated with the Derivo Embolization Device, a Novel Second-Generation Flow Diverter [J].
Fujimura, Soichiro ;
Brehm, Alex ;
Takao, Hiroyuki ;
Uchiyama, Yuya ;
Karagiozov, Kostadin ;
Fukudome, Koji ;
Yamamoto, Makoto ;
Murayama, Yuichi ;
Psychogios, Marios-Nikos .
WORLD NEUROSURGERY, 2022, 159 :E252-E259
[10]   Stent-Assisted Coiling of Intracranial Bifurcation Aneurysms Leads to Immediate and Delayed Intracranial Vascular Angle Remodeling [J].
Gao, B. ;
Baharoglu, M. I. ;
Cohen, A. D. ;
Malek, A. M. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (04) :649-654