Direct measurement of intra-abdominal pressure with a solid microtranducer

被引:22
|
作者
Pracca F.F. [1 ]
Biestro A.A. [1 ]
Moraes L. [1 ]
Puppo C.B. [1 ]
Calvo S.M. [1 ]
Gorrasi J. [1 ]
Cancela M. [1 ]
机构
[1] Department of Intensive Care Medicine, Hospital de Clinicas, Montevideo 11600, Avda Italia s/n
关键词
Abdominal compartment syndrome; Codman microsensor; Intra-abdominal pressure; Intravesical pressure; Pressure monitor;
D O I
10.1007/s10877-007-9071-2
中图分类号
学科分类号
摘要
Objective: To describe a direct intra-abdominal pressure (IAP) measurement technique using a solid microsensor comparing its values with the ones simultaneously obtained by means of Kron's technique. Comparative study between two different methods to measure intra-abdominal pressure in a multidisciplinary intensive care unit of a university hospital. Methods: In 11 critical patients considered irreversibly ill, IAP was simultaneously measured via Kron's technique (IAPK) and by direct measure (IAPC) through an abdominal tap with a Codman microsensor, inserted through it. Several measurements were obtained at different PEEP levels (0, 10 and 20 cm of H20) and bed inclination (0°, 40° and 60°). Results: 92 simultaneous measurements of IAPK and IAPC were made. The difference between both measurements (mean ±SD) were: 0.286 ± 0.938 mmHg. The correlation coefficient was r = 0.98. Bland-Altman plot showed a narrow distribution: 95% of the differences were between 1.87 mmHg of each averaged value. No complications with IAPC measurements were found. Conclusions: Direct IAP measurement with a Codman microsensor allows continuous monitoring without urinary tract manipulation, is simple to use and to calibrate, minimally invasive and appropriate for patients at risk to develop abdominal compartmental syndrome. Due to its cost it should be reserved for selected critical patients where standard techniques are contraindicated or can be inaccurate. © Springer Science+Business Media, Inc. 2007.
引用
收藏
页码:167 / 170
页数:3
相关论文
共 50 条
  • [21] Clinical evaluation of an air-capsule technique for the direct measurement of intra-abdominal pressure after elective abdominal surgery
    Otto J.
    Kaemmer D.
    Biermann A.
    Jansen M.
    Dembinski R.
    Schumpelick V.
    Schachtrupp A.
    BMC Surgery, 8 (1)
  • [22] Intra-abdominal pressure, intra-abdominal hypertension, and pregnancy: a review
    Rosaleen Chun
    Andrew W Kirkpatrick
    Annals of Intensive Care, 2
  • [23] A user's guide to intra-abdominal pressure measurement
    Sugrue, Michael
    De Waele, Jan J.
    De Keulenaer, Bart L.
    Roberts, Derek J.
    Malbrain, Manu L. N. G.
    ANAESTHESIOLOGY INTENSIVE THERAPY, 2015, 47 (03) : 241 - 251
  • [24] Abdominocentesis and intra-abdominal pressure measurement in small animals
    Munguia, George G.
    Thomovsky, Elizabeth
    JAVMA-JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 2024, 262 (09): : 1 - 1
  • [25] Transvesical Intra-Abdominal Pressure Measurement in Newborn: What Is the Optimal Saline Volume Instillation?
    Defontaine, Anne
    Tirel, Olivier
    Costet, Nathalie
    Beuchee, Alain
    Ozanne, Bruno
    Gaillot, Theophile
    Arnaud, Alexis Pierre
    Wodey, Eric
    PEDIATRIC CRITICAL CARE MEDICINE, 2016, 17 (02) : 144 - 149
  • [26] INTRAPERITONEAL PRESSURE AND INTRA-ABDOMINAL PRESSURE: ARE THEY THE SAME?
    Al-Hwiesh, Abdullah
    Al-Mueilo, Sameer
    Saeed, Ibrahiem
    Al-Muhanna, Fahd A.
    PERITONEAL DIALYSIS INTERNATIONAL, 2011, 31 (03): : 315 - 319
  • [27] Intra-abdominal pressure measurement using a bladder catheter
    Rozov, R
    Pottecher, T
    Launoy, A
    ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 2004, 23 (04): : 433 - 434
  • [28] Non-invasive measurement of intra-abdominal pressure: a preliminary study
    van Ramshorst, G. H.
    Lange, J. F.
    Goossens, R. H. M.
    Agudelo, N. L.
    Kleinrensink, G. J.
    Verwaal, M.
    Flipsen, S. F. J.
    Hop, W. C. J.
    Wauben, L. S. G. L.
    Jeekel, J.
    PHYSIOLOGICAL MEASUREMENT, 2008, 29 (08) : N41 - N47
  • [29] Semicontinuous intra-abdominal pressure measurement using an intragastric Compliance catheter
    De Waele, Jan J.
    Berrevoet, F.
    Reyntjens, K.
    Pletinckx, P.
    De laet, I.
    Hoste, E.
    INTENSIVE CARE MEDICINE, 2007, 33 (07) : 1297 - 1300
  • [30] Intra-abdominal pressure, intra-abdominal hypertension, and pregnancy: a review
    Chun, Rosaleen
    Kirkpatrick, Andrew W.
    ANNALS OF INTENSIVE CARE, 2012, 2